background image

Figure 3.3-47  802.1x/Radius - Misc Configuration...................99 
Figure 3.3-48  Static MAC Addresses interface .......................100 
Figure 3.3-49  MAC Filtering interface....................................101 
Figure 3.3-50  All MAC Address interface ..............................102 
Figure 3.3-51  Multicast Filtering interface..............................103 
Figure 3.3-52  Factory Default interface ..................................104 
Figure 3.3-53  Save Configuration interface ............................105 
Figure 3.3-54  System Reboot interface ...................................106 

Chapter 4

 

Troubleshooting .......................... 109

 

Appendix A    Pin Assignments & Wiring ....... 111

 

Figure A.1: RJ-45 Pin Assignments..........................................111 
Figure A.2: EIA/TIA-568B.......................................................111 
Figure A.3: EIA/TIA-568A ......................................................111 
Figure A.4: DB 9-pin female connector ...................................112 

Appendix B    Compatible SFP Transceivers . 115

 

EKI-2748FI_Manual     

                                     

Summary of Contents for EKI-2748FI

Page 1: ...EKI 2748FI 8G ports Industrial Managed Redundant Gigabit Ethernet Switch 4 Gigabit Copper and 4 Gigabit SFP User Manual ...

Page 2: ...form or by any means without the prior written permission of Advantech Co Ltd Information provided in this manual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknowledgements Microsoft Windows and MS DOS are registered trademarks of Microsoft Corp All ot...

Page 3: ...ent materials service time and freight Please consult your dealer for more details If you think you have a defective product follow these steps 1 Collect all the information about the problem encountered For example network speed Advantech products used other hardware and software used etc Note anything abnormal and list any onscreen messages you get when the problem occurs 2 Call your dealer and ...

Page 4: ...ergy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Technical Support and Assistance Step 1 Visit the Advantech web site at www advantech com s...

Page 5: ...hing over the power cord 10 All cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect it from the power source to avoid damage by transient over voltage 12 Never pour any liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service pe...

Page 6: ... precautions to protect yourself from harm and the products from damage 1 To avoid electrical shock always disconnect the power from your equipment chassis before you work on it 2 Disconnect power before making any configuration changes EKI 2748FI_Manual vi ...

Page 7: ...iew 24 2 3 Mounting 25 2 3 1 Wall mounting 25 Figure 2 5 Combine the Metal Mounting Kit 25 2 3 2 DIN rail Mounting 26 Figure 2 6 Installation to DIN rail Step 1 26 Figure 2 7 Installation to DIN rail Step 2 27 2 4 Network Connection 28 2 5 Connection to a Fiber Optic Network 28 Figure 2 8 Transceiver to the SFP slot 28 Figure 2 9 Transceiver Inserted 29 Figure 2 10 LC connected to the transceiver ...

Page 8: ... Set 44 Table 3 9 QOS Commands Set 44 3 2 10 IGMP Commands Set 45 Table 3 10 QOS Commands Set 45 3 2 11 Mac Filter Table Commands Set 45 Table 3 11 Mac Filter Table Commands Set 45 3 2 12 SNMP Commands Set 46 Table 3 12 SNMP Commands Set 46 3 2 13 Port Mirroring Commands Set 47 Table 3 13 Port Mirroring Commands Set 47 3 2 14 802 1x Commands Set 47 Table 3 14 802 1x Commands Set 47 3 2 15 TFTP Com...

Page 9: ...regator Information 73 Figure 3 3 25 State Activity 74 Figure 3 3 26 Port Mirroring 75 Figure 3 3 27 Rate Limiting 76 Figure 3 3 28 DMI Interface 77 3 3 3 Protocol 78 Figure 3 3 29 VLAN Configuration 78 Figure 3 3 30 Port based mode 79 Figure 3 3 31 Port based mode Add interface 80 Figure 3 3 32 Port Based Edit Delete interface 81 Figure 3 3 33 802 1Q VLAN Configuration 83 Figure 3 3 34 Edit Group...

Page 10: ...ring interface 103 Figure 3 3 52 Factory Default interface 104 Figure 3 3 53 Save Configuration interface 105 Figure 3 3 54 System Reboot interface 106 Chapter 4 Troubleshooting 109 Appendix A Pin Assignments Wiring 111 Figure A 1 RJ 45 Pin Assignments 111 Figure A 2 EIA TIA 568B 111 Figure A 3 EIA TIA 568A 111 Figure A 4 DB 9 pin female connector 112 Appendix B Compatible SFP Transceivers 115 EKI...

Page 11: ...xi Contents Overview Sections include z Introduction z Features z Specifications z Packing List z Safety Precaution CHAPTER ...

Page 12: ...ingle fiber transmissions This means that you can easily change the transmission mode and distance of the switch by simply pulling out the SFP transceiver and plugging in a different one The SFP transceivers are hot swappable and plug and play Also the fact that the switch has four of these slots means that the network manager can for example have one 10km transceiver in one slot and one 110km in ...

Page 13: ...I 2748FI is between 40 75 With such a wide range you can use the EKI 2748FI in some of the harshest industrial environments that exist 1 1 7 Easy Troubleshooting LED indicators make troubleshooting quick and easy Each 10 100 1000 Base TX port has 2 LEDs that display the link status transmission speed and collision status Also the three power indicators P1 P2 and P Fail help you diagnose immediatel...

Page 14: ... Serial Console Windows Utility SNMP Control VLAN GVRP QoS IGMP Snooping LACP Rate Limit Security IP MAC and port binding DHCP Server IP access list 802 1x SNMPv3 Diagnostic Port statistic Port Mirroring RMON Trap SMTP Alert Syslog Dual 12 48 VDC power input and 1 Relay Output Robust mechanism and special heat spreader design Supports operating temperatures from 40 75 SFP supports DMI function EKI...

Page 15: ...pper Link Activity Speed 1000Mbps SFP Link Activity Console RS 232 RJ 45 Network Management Configuration Web browser Telnet Serial Console Windows Utility TFTP Port Speed Duplex Configuration SNMP v1 v2c v3 VLAN IEEE 802 1Q GVRP Port based VLAN Redundancy ADVANTECH X Ring Recovery time 10ms at 30pcs full loading ring structure Dual Homing Couple Ring 802 1w D RSTP STP Security IP Access security ...

Page 16: ... rail wall Environment Operating Temperature 40 75o C Operating Humidity 5 95 non condensing Storage Temperature 40 85o C Storage Humidity 5 95 non condensing Certifications Safety UL508 Hazardous Location UL cUL Class I Division 2 Group A B C and D EMC FCC Class A EU CE EN61000 3 2 3 CE EN61000 6 2 4 CE EN61000 4 2 3 4 5 6 8 11 12 Freefall IEC60068 2 32 Shock IEC60068 2 27 Vibration IEC60068 2 6 ...

Page 17: ... manual 2 x Wall Mounting Bracket and Screws 1 x DIN rail Mounting Bracket and Screws 1 x 8 pin RJ 45 to RS 232 serial cable 1 x DC Jack Cable φ2 0 150mm 1 x EKI 2748FI Startup Manual 1 5 Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input 17 Chapter1 ...

Page 18: ...EKI 2748FI_Manual 18 ...

Page 19: ...19 Chapter 2 Installation Sections include z LED Indicators z Dimensions z Mounting z Network Connection z Connection to a Fiber Optic Network z Power Connection CHAPTER ...

Page 20: ...X ring group On Power input 1 is active PWR1 Green Off Power input 1 is inactive On Power input 2 is active PWR2 Green Off Power input 2 is inactive On Power input 1 or 2 is inactive or port link down depends on Fault Relay Alarm configuration P Fail Red Off Power input 1 and 2 are both active or no power input On SFP port is linking Flashing Data is transmitting or receiving Link Active P5 P8 Gre...

Page 21: ...2 2 Dimensions unit mm Figure 2 1 Front View 21 Chapter 2 ...

Page 22: ...Figure 2 2 Side View EKI 2748FI_Manual 22 ...

Page 23: ...Figure 2 3 Rear View 23 Chapter 2 ...

Page 24: ...Figure 2 4 Top View EKI 2748FI_Manual 24 ...

Page 25: ... using the included mounting kit Then hang on the EKI 2748FI to the nails on the wall First use the screws included in the package to combine the EKI 2748FI and metal mounting kit And then you can install the device firmly via the components please see Figure 2 5 as below Figure 2 5 Combine the Metal Mounting Kit 25 Chapter 2 ...

Page 26: ...s screwed on the industrial switch when out of factory If the DIN rail kit is not screwed on the industrial switch please screw the DIN rail kit on the switch first First hang the EKI 2748FI to the DIN rail with angle of inclination See Figure 2 6 Figure 2 6 Installation to DIN rail Step 1 EKI 2748FI_Manual 26 ...

Page 27: ...Then hook the device over the DIN rail and let it drop down straight to slide over the rail smoothly Figure 2 7 Installation to DIN rail Step 2 27 Chapter 2 ...

Page 28: ...r multi mode or single mode fiber according to the inserted SFP transceiver With fiber optic it transmits speed up to 1000 Mbps and you can prevent noise interference from the system and transmission distance up to 110 km depending on the mini GBIC transceivers The small form factor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data co...

Page 29: ...Figure 2 9 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver Figure 2 10 LC connected to the transceiver 29 Chapter 2 ...

Page 30: ...below First press the upper side of the LC connector to release from the transceiver and pull it out Figure 2 11 Remove LC connector Second push down the metal loop and pull the transceiver out by the plastic handle Figure 2 12 Pull out from the slot EKI 2748FI_Manual 30 ...

Page 31: ...ontact Fault Alarm Application Example 24Vdc 1A Resistance Figure 2 13 Pin Assignment of the Power Connector You can connect an alarm indicator buzzer or other signaling equipment through the relay output The relay opens if power input 1 2 fails or port link down break Open means if you connect relay output with an LED the light would be off 31 Chapter 2 ...

Page 32: ...but its recovery time is less than STP RSTP The figure below is a sample of X Ring application Note The Ethernet switches with firmware version before v3 0 use the X Ring function that has the limitation as follows However the one with firmware version after v3 0 included use the X Ring Pro function that gets rid of the limitation 1 The X Ring is supposed to recover from connection failure within ...

Page 33: ...function that has the limitations as follows However the ones with firmware version after v3 0 included use the X Ring Pro function that gets rid of the limitations 1 To ensure the coupling ring to work normally the connection between control ports of each X ring group as the figure illustrated above should always be active 2 The switches to be configured as members of the Coupling Ring group cann...

Page 34: ...hes with firmware version before v3 0 use the X Ring function that has the limitations as follows However the ones with firmware version after v3 0 included use the X Ring Pro function that gets rid of the limitations 1 In Dual Homing application architecture the upper level switches need to enable their Rapid Spanning Tree protocol 2 The switches to be configured as members of the Dual Homing gro...

Page 35: ...35 Chapter3 Configuration Sections include z RS 232 Console z Commands Set z Web Browser CHAPTER ...

Page 36: ...command Attach the supplied cable which one end is RJ 45 and the other end is female DB9 to connect EKI 2748FI and your host PC or terminal The connected PC or terminal must support the terminal emulation program Figure 3 1 1 Console Cable From the Windows desktop click Start Programs Accessories Communications HyperTerminal to open the Hyper Terminal program Figure 3 1 2 Launching Hyper Terminal ...

Page 37: ... and None for Flow Control Figure 3 1 3 COM Port Properties Setting Press Enter to bring the login screen If you can not find the login screen press Enter one more time The default user name and password are both admin Key in the user name and password to enter the command line interface Figure 3 1 4 Login Screen RS 232 Configuration 37 Chapter3 ...

Page 38: ...After you have logged in to the system you will see a command prompt To enter CLI management interface type in enable command Figure 3 1 5 Command Line Interface EKI 2748FI_Manual 38 ...

Page 39: ...ation Global Configuration Enter the configure command while in privileged EXEC mode switch config To exit to the Privileged EXEC mode enter exit or end Use this mode to configure the parameters to be applied to your switch VLAN database Enter the vlan database command while in privileged EXEC mode switch vlan To return to the User EXEC mode enter exit Use this mode to configure VLAN specific para...

Page 40: ...Server switch config dhcpserver enable Dhcpserver disable G Disable DHCP Server switch config no dhcpserver dhcpserver lowip Low IP G Configure low IP address for IP pool switch config dhcpserver lowip 192 168 1 100 dhcpserver highip High IP G Configure high IP address for IP pool switch config dhcpserver highip 192 168 1 200 dhcpserver subnetmask Subnet mask G Configure subnet mask for DHCP clien...

Page 41: ... if bandwidth type all bandwidth type broadcast multicast flooded unicast I Set interface ingress limit frame type to accept broadcast multicast and flooded unicast frame switch config interface fastEthernet 2 switch config if bandwidth type broadcast multicast flooded unicast bandwidth type broadcast multicast I Set interface ingress limit frame type to accept broadcast and multicast frame switch...

Page 42: ... list This parameter could be a port range ex 1 4 or a port list separate by a comma ex 2 3 6 Workport The amount of work ports this value could not be less than zero or be large than the amount of member ports switch config aggregator group 1 1 4 lacp workp 2 or switch config aggregator group 2 1 4 3 lacp workp 3 aggregator group GroupID Port list nolacp G Assign a static trunk group GroupID 1 3 ...

Page 43: ...rt PortNumber trunk link tag TaggedVID List V Assign a trunk link for VLAN by port if the port belong to a trunk group this command can t be applied switch vlan vlan 8021q port 3 trunk link tag 2 3 6 99 or switch vlan vlan 8021q port 3 trunk link tag 3 20 vlan 8021q port PortNumber hybrid link untag UntaggedVID tag TaggedVID List V Assign a hybrid link for VLAN by port if the port belong to a trun...

Page 44: ...s forwarding switch config spanning tree forward time 20 stp path cost 1 200000000 I Use the spanning tree cost interface configuration command to set the path cost for Spanning Tree Protocol STP calculations In the event of a loop spanning tree considers the path cost when selecting an interface to place into the forwarding state switch config interface fastEthernet 2 switch config if stp path co...

Page 45: ... igmp multi P Displays the details of an IGMP snooping entries switch show igmp multi no igmp G Disable IGMP snooping function switch config no igmp no igmp query G Disable IGMP query switch no igmp query 3 2 11 Mac Filter Table Commands Set Table 3 11 Mac Filter Table Commands Set Commands Level Description Example mac address table static hwaddr MAC I Configure MAC address table of interface sta...

Page 46: ...er test01 group G1 password AuthPW PrivPW snmpv3 access context name Context Name group Group Name security level NoAuthNoPriv AuthNoPriv AuthPriv match rule Exact Prifix views Read View Name Write View Name Notify View Name G Configure the access table of SNMPV3 agent switch config snmpv3 access context name Test group G1 security level AuthPriv match rule Exact views V1 V1 V1 snmpv3 mibview view...

Page 47: ...s server IP switch config 8021x system radiusip 192 168 1 1 8021x system serverport port ID G Use the 802 1x system server port global configuration command to change the radius server port switch config 8021x system serverport 1815 8021x system accountport port ID G Use the 802 1x system account port global configuration command to change the accounting port switch config 8021x system accountport...

Page 48: ...f TFTP server and the file name of image switch config upgrade lash upgrade_fw 3 2 16 SystemLog SMTP and Event Table 3 16 SysLog SMTP Event Commands Set Commands Level Description Example systemlog ip IP address G Set System log server IP address switch config systemlog ip 192 168 1 100 systemlog mode client server both G Specified the log mode switch config systemlog mode both show systemlog E Di...

Page 49: ...e G Enable SNTP function switch config sntp enable sntp daylight G Enable daylight saving time if SNTP function is inactive this command can t be applied switch config sntp daylight sntp daylight period Start time End time G Set period of daylight saving time if SNTP function is inactive this command can t be applied Parameter format yyyymmdd hh mm switch config sntp daylight period 20060101 01 01...

Page 50: ...tch show ring no ring G Disable X ring switch config no ring no ring master G Disable ring master switch config no ring master no ring couplering G Disable couple ring switch config no ring couplering no ring dualhoming G Disable dual homing switch config no ring dualhoming 3 2 19 LLDP Command Set Table 3 19 LLDP Commands Set Commands Level Description Example lldp enable G Enable LLDP function sw...

Page 51: ... use web management install the industrial switch on the network and make sure that any one of PCs on the network can connect with the industrial switch through the web browser The industrial switch default value of IP subnet mask username and password are as below IP Address 192 168 1 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 254 User Name admin Password admin Open Internet Explorer a...

Page 52: ...n find the tree menu structure of the Ethernet switch in the left side Click the symbol to unroll the hiding hyperlink and click any one of the hyperlinks to open its function page Figure 3 3 3 Main page EKI 2748FI_Manual 52 ...

Page 53: ... maximum length is 64 bytes System Contact Enter the name of contact person or organization Firmware Version Displays the switch s firmware version Kernel Version Displays the kernel software version MAC Address Displays the unique hardware address assigned by manufacturer default Warning Don t set 0 for the first segment of the subnet mask and default gateway 000 xxx xxx xxx Refresh the web scree...

Page 54: ... Assign the IP address that the network is using If DHCP client function is enabled and then the user doesn t need to assign the IP address And the network DHCP server will assign the IP address displaying in this column for the industrial switch The default IP is 192 168 1 1 Subnet Mask Assign the subnet mask to the IP address If DHCP client function is enabled and then the user does not need to ...

Page 55: ... system can be a DHCP server DHCP Server Enable or Disable the DHCP Server function Enable the switch will be the DHCP server on your local network Low IP Address Type in an IP address Low IP address is the beginning of the dynamic IP range For example dynamic IP is in the range between 192 168 1 100 192 168 1 200 In contrast 192 168 1 100 is the Low IP address High IP Address Type in an IP addres...

Page 56: ...DHCP Server Client Entries When the DHCP server function is active the system will collect the DHCP client information and displays it here Figure 3 3 7 DHCP Server Client Entries EKI 2748FI_Manual 56 ...

Page 57: ... dynamic IP address to the port When the device is connecting to the port and asks for IP assigning the system will assign the IP address that has been assigned before to the connected device Figure 3 3 8 DHCP Server Port IP Binding 57 Chapter3 ...

Page 58: ...vides the functions to allow the user to update the switch firmware Before updating make sure you have your TFTP server ready and the firmware image is on the TFTP server TFTP Server IP Address Fill in your TFTP server IP Firmware File Name Type in the name of the firmware image And then click Apply Figure 3 3 9 TFTP Update Firmware EKI 2748FI_Manual 58 ...

Page 59: ...re doing that you must put the image file on TFTP server first and the switch will download back the flash image TFTP Server IP Address Fill in the TFTP server IP Restore File Name Fill in the correct restore file name Click Apply Figure 3 3 10 TFTP Restore Configuration 59 Chapter3 ...

Page 60: ...rent Flash ROM value from the switch to TFTP server for restoring later TFTP Server IP Address Fill in IP address of the TFTP server Backup File Name Fill in the file name Click Apply Figure 3 3 11 TFTP Backup Configuration EKI 2748FI_Manual 60 ...

Page 61: ... only be reserved in the switch s RAM until next reboot When Syslog Client Mode is set as Server Only the system log will only be sent to the syslog server and you have to type the IP address in the Sysylog Server IP Address column If the Syslog Client Mode is set as Both the system log will be reserved in the switch s RAM and sent to server Click Reload to refresh the events log Click Clear to cl...

Page 62: ... event log comes from Authentication Tick the checkbox to enable this function configuring the email account and password for authentication when Email Alert enabled this function will then be available Mail Account Set up the email account e g Tomadmin to receive the alert It must be an existing email account on the mail server which you had set up in SMTP Server IP Address column Password Type i...

Page 63: ...og event Device warm start When the device executes warm start the system will issue a log event Authentication Failure When the SNMP authentication fails the system will issue a log event X ring topology change When the X ring topology has changed the system will issue a log event Port event selection Also before the drop down menu items are available the Syslog Client Mode column on the Syslog C...

Page 64: ... function of lighting up the FAULT LED on the panel when power fails Port Link Down Broken Tick the checkbox to enable the function of lighting up FAULT LED on the panel when ports states are link down or broken Figure 3 3 15 Fault Relay Alarm EKI 2748FI_Manual 64 ...

Page 65: ...onversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight 4 hours 8 am EST Eastern Standard CDT Central Daylight 5 hours 7 am CST Central Standard MDT Mountain Daylight 6 hours 6 am MST Mountain Standard PDT Pacific Daylight 7 hours 5 am PST Pacific Standard ADT Alaskan Daylight 8 ...

Page 66: ...aving Period Set up the Daylight Saving beginning time and Daylight Saving ending time Both will be different in every year Daylight Saving Offset mins For non US and European countries specify the amount of time for day light savings Synchronization Interval secs The Synchronization Interval is used for sending synchronizing packets periodically Users can assign the time ranging from 64 to 1024 s...

Page 67: ...10 will be allowed to access this switch via HTTP service Enable Telnet Server When this checkbox is ticked the IP addresses among Security IP1 IP10 will be allowed to access this switch via telnet service Security IP 1 10 The system allows the user to assign up to 10 specific IP addresses for access security Only these 10 IP addresses can access and manage the switch through the HTTP Telnet servi...

Page 68: ...management security issue User Name Key in the new user name The default is admin Password Key in the new password The default is admin Confirm Password Re type the new password And then click Apply to apply the configuration Figure 3 3 18 User Authentication EKI 2748FI_Manual 68 ...

Page 69: ...cket Tx Good Packet The counts of transmitting good packets via this port Tx Bad Packet The counts of transmitting bad packets including undersize less than 64 bytes oversize CRC Align errors fragments and jabbers packets via this port Rx Good Packet The counts of receiving good packets via this port Rx Bad Packet The counts of receiving bad packets including undersize less than 64 bytes oversize ...

Page 70: ...this column is read only Duplex It is available for selecting when the Negotiation column is set as Force When the Negotiation column is set as Auto this column is read only Flow Control Set flow control function as Enable or Disable When enabled once the device exceed the input data rate of another device as a result the receiving device will send a PAUSE frame which halts the transmission of the...

Page 71: ...he trunk group is a static trunk group The advantage of having the LACP disabled is that a port joins the trunk group without any handshaking with its member ports But member ports won t know that they should be aggregated together to form a logic trunk group Work ports This column field allows the user to type in the total number of active port up to four With LACP trunk group you create a trunk ...

Page 72: ...u have set up the aggregator setting with LACP disabled you will see the local static trunk group information as below Figure 3 3 22 2 work ports with LACP disabled Figure 3 3 23 Static trunking group of 2 ports EKI 2748FI_Manual 72 ...

Page 73: ...n you have set up the aggregator setting of two interconnected switches with LACP enabled you will see the respective LACP trunk group information as below Figure 3 3 24 Aggregator Information 73 Chapter3 ...

Page 74: ... Passive Active The port automatically sends LACP protocol packets Passive The port does not automatically send LACP protocol packets and responds only if it receives LACP protocol packets from the opposite device Note A link having either two active LACP nodes or one active node can perform dynamic LACP trunk A link having two passive LACP nodes will not perform dynamic LACP trunk because both po...

Page 75: ...nation mirroring port for monitoring both RX and TX traffic which come from the source port Or use one of two ports for monitoring RX traffic only and the other one for TX traffic only The user can connect the mirroring port to LAN analyzer or Netxray Source Port The ports that the user wants to monitor All monitored port traffic will be copied to mirroring destination port The user can select mul...

Page 76: ...ion The egress rate only supports All type All ports support port ingress and egress rate control For example assume port 1 is 10Mbps the user can set the effective egress rate of port 1 as 1Mbps ingress rate 500Kbps The switch performs the ingress rate by packet counter to meet the specified rate Ingress Enter the port effective ingress rate The default value is 0 Egress Enter the port effective ...

Page 77: ...etecting the exceptional value The action includes the following options Off The port will be shut down when detecting the exceptional value e mail The port will send an e mail to administrator when detecting the exceptional value Figure 3 3 28 DMI Interface Port 7 and port 8 support the DMI function The DMI table shows five parameters in rows and warning alarm status indicators corresponding to e...

Page 78: ...the same VLAN will receive traffic from the ones of the same VLAN Basically creating a VLAN from a switch is logically equivalent of reconnecting a group of network devices to another Layer 2 switch However all the network devices are still plugged into the same switch physically The switch supports Port based and 802 1Q tagged based VLAN The default configuration of VLAN operation mode is Disable...

Page 79: ...groups it itself has to be either capable of tagging packets it sends with VLAN tags or attached to a VLAN aware bridge that is capable of classifying and tagging the packet with different VLAN ID based on not only default PVID but also other information about the packet such as the protocol Figure 3 3 30 Port based mode Pull down the selection item and focus on Port Based then click Apply to set ...

Page 80: ...AN ID Add the port number having selected into the right field to group these members to be a VLAN group or remove any of them listed in the right field from the VLAN And then click Apply to have the settings take effect You will see the VLAN displays EKI 2748FI_Manual 80 ...

Page 81: ...se Delete to delete the VLAN Use Edit to modify group name VLAN ID or add remove the members of the existing VLAN group Note Remember to execute the Save Configuration action otherwise the new configuration will lose when switch power off 81 Chapter3 ...

Page 82: ...switch thus has a current record of all the other end stations and switches that can be reached 802 1Q Configuration Pull down the selection item and focus on 802 1Q then click Apply to set the VLAN Operation Mode in 802 1Q mode Enable GVRP Protocol Tick the checkbox to enable GVRP protocol This checkbox is available while the VLAN Operation Mode is in 802 1Q mode Management VLAN ID The default is...

Page 83: ...Figure 3 3 33 802 1Q VLAN Configuration 83 Chapter3 ...

Page 84: ...ect the VLAN group in the table list Click Edit Figure 3 3 34 Edit Group Configuration interface Having clicked the Edit button you can change the VLAN group name and VLAN ID Figure 3 3 35 802 1Q Group Configuration Edit Click Apply EKI 2748FI_Manual 84 ...

Page 85: ...e is changed the user must reboot the switch The value must be a multiple of 4096 according to the protocol standard rule Max Age 6 40 The number of seconds a switch waits without receiving Spanning tree Protocol configuration messages before attempting a reconfiguration Enter a value between 6 through 40 Hello Time 1 10 The time that controls the switch to send out the BPDU packet to check RSTP c...

Page 86: ...n whether the port concerned can only be connected to exactly one other bridge i e it is served by a point to point LAN segment or can be connected to two or more bridges i e it is served by a shared medium LAN segment This function allows the P2P status of the link to be manipulated administratively True is P2P enabling False is P2P disabling Admin Edge The port directly connected to end stations...

Page 87: ...tring set and remove the unwanted community string String Fill the name string RO Read only Enables requests accompanied by this community string to display MIB object information RW Read write Enables requests accompanied by this community string to display MIB object information and to set MIB objects Click Add To remove the community string select the community string that you have defined and ...

Page 88: ...ine a management station as a trap manager assign an IP address enter the SNMP community strings and select the SNMP trap version IP Address Enter the IP address of the trap manager Community Enter the community string Trap Version Select the SNMP trap version type v1 or v2c Click Add To remove the community string select the community string listed in the current managers field and click Remove F...

Page 89: ...er table Group Name Set up the group name Click Add to add context name Click Remove to remove the unwanted context name Access Table Configure SNMP v3 access table Context Prefix Set up the context name Group Name Set up the group Security Level Set up the access level Context Match Rule Select the context match rule Read View Name Set up the read view Write View Name Set up the write view Notify...

Page 90: ...Figure 3 3 40 SNMP V3 Configuration interface EKI 2748FI_Manual 90 ...

Page 91: ... to set the queuing policy for each port Port x Each port has 4 priority levels High Middle Low and Lowest to be chosen Click Apply to have the settings taken effect COS Configuration Set up the COS priority level With the drop down selection item of Priority Type above being selected as COS only COS first this control item will then be available to set the queuing policy for each port COS priorit...

Page 92: ...Figure 3 3 41 QoS Configuration interface EKI 2748FI_Manual 92 ...

Page 93: ...st group Report A message sent by a host to the querier to indicate that the host wants to be or is a member of a given group indicated in the report message Leave Group A message sent by a host to the querier to indicate that the host has quit being a member of a specific multicast group The switch supports IP multicast You can enable IGMP protocol via setting the IGMP Configuration page to see t...

Page 94: ...er by checking the corresponding LED indicator on the panel of the switch The system also supports the Couple Ring topology that can connect two X Ring groups for the redundant backup function Besides the Dual Homing topology can prevent connection lose between the X Ring group and the upper level core switch Enable X Ring To enable the X Ring function tick the check box beside the Enable Ring str...

Page 95: ...ing function users must disable the RSTP first The X Ring function and RSTP function cannot both be activated on a single switch Remember to execute the Save Configuration action otherwise the new configuration will lose when switch powers off 95 Chapter3 ...

Page 96: ...vertise its information to other nodes on the network and store the information it discovers LLDP Protocol Disable or enable the LLDP function LLDP Interval Set the interval of learning the information in seconds Click Apply Figure 3 3 44 LLDP Configuration interface EKI 2748FI_Manual 96 ...

Page 97: ...configure the parameters of this function IEEE 802 1x Protocol Enable or disable 802 1x protocol Radius Server IP Assign the RADIUS Server IP address Server Port Set the UDP destination port for authentication requests to the specified RADIUS Server Accounting Port Set the UDP destination port for accounting requests to the specified RADIUS Server Shared Key Set an encryption key for using during ...

Page 98: ...te Accept The specified port is required to be held in the Authorized state Authorized The specified port is set to the Authorized or Unauthorized state in accordance with the outcome of an authentication exchange between the Supplicant and the authentication server Disable When disabled the specified port works without complying with 802 1x protocol Click Apply Figure 3 3 46 802 1x Radius Port Se...

Page 99: ...me the switch waits for a supplicant response to an EAP request Server Timeout Set the period of time the switch waits for a server response to an authentication request Max Requests Set the number of authentication that must time out before authentication fails and the authentication session ends Reauth period Set the period of time which clients connected must be re authenticated Click Apply Fig...

Page 100: ...tive on the network again You can add modify delete a static MAC address MAC Address Table Static MAC Address You can add static MAC address in the switch MAC table here MAC Address Enter the MAC address of the port that should permanently forward traffic regardless of the device network activity Port No Pull down the selection menu to select the port number Click Add If you want to delete the MAC...

Page 101: ...t you want to filter Click Add If you want to delete the MAC address from filtering table select the MAC address and click Delete MAC Address Table All MAC Addresses You can view the port that connected device s MAC address and the related devices MAC address Select the port The selected port of static dynamic MAC address information will be displayed in here Click Clear MAC Table to clear the cur...

Page 102: ...Figure 3 3 50 All MAC Address interface EKI 2748FI_Manual 102 ...

Page 103: ...ltering network devices only forward multicast traffic to the ports that are connected to registered end stations IP Address Assign a multicast group IP address in the range of 224 0 0 0 239 255 255 255 Member Ports Tick the check box beside the port number to include them as the member ports in the specific multicast group IP address Click Clear MAC Table to clear the current port static MAC addr...

Page 104: ... default configuration Tick the check boxes to keep the current IP address user name and password before reset Click Reset to reset all configurations to the default value Figure 3 3 52 Factory Default interface EKI 2748FI_Manual 104 ...

Page 105: ... Save all configurations that you have made in the system To ensure the all configuration will be saved click Save to save the all configuration to the flash memory Figure 3 3 53 Save Configuration interface 105 Chapter3 ...

Page 106: ...System Reboot Reboot the switch in software reset Click Reboot to reboot the system Figure 3 3 54 System Reboot interface EKI 2748FI_Manual 106 ...

Page 107: ...107 Chapter3 ...

Page 108: ...EKI 2748FI_Manual 108 Troubleshooting CHAPTER ...

Page 109: ...th of any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the switch can be easily monitored through panel indicators which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light on when the power cord is plugged in you may have a problem with power ...

Page 110: ...EKI 2748FI_Manual 110 Pin Assignments Wiring APPENDIX ...

Page 111: ...Appendix A Pin Assignments Wiring It is suggested to adopt ELA TIA as the wiring of the RJ 45 Figure A 1 RJ 45 Pin Assignments Figure A 2 EIA TIA 568B Figure A 3 EIA TIA 568A 111 ...

Page 112: ...Figure A 4 DB 9 pin female connector DB9 Connector RJ 45 Connector NC 1 Orange White 2 2 Orange 3 3 Green White NC 4 Blue 5 5 Blue White NC 6 Green NC 7 Brown White NC 8 Brown EKI 2748FI_Manual 112 ...

Page 113: ...113 ...

Page 114: ...EKI 2748FI_Manual 114 Compatible SFP Transceivers APPENDIX ...

Page 115: ...t Number Mode Transmission Distance 1 AVAGO AFBR 5710PZ 550m 2 APAC LM28 C3S TC N 550m 3 HOATECH HTI8512 X5ATO 550m 4 SPACE SHUTTLE S56L S85 6L N Multi mode 550m SP GB LX 10km SP GB ELX 20km 5 LuminentOIC SP GB XD 50km 6 AVAGO AFCT 5710PZ 10km 7 APAC LS38 C3M TC N 20km 8 SPACE SHUTTLE S56L L13 6L N Single mode 10km 115 ...

Reviews: