![Advantech EKI-1500-CE Series User Manual Download Page 67](http://html1.mh-extra.com/html/advantech/eki-1500-ce-series/eki-1500-ce-series_user-manual_2858308067.webp)
EKI-1500-CE Series User Manual
56
6.5
Port Configuration
The serial port configuration menu has Basic, Operation Mode, and Advanced Set-
tings.
6.5.1
Basic
The Basic menu allows for the configuration of the serial interface type, baud rate,
parity, data / stop bits, and flow control for port configuration.
To access this page, click
Port Configuration
>
Basic
.
Figure 6.4 Port Configuration > Basic
The following table describes the items in the previous figure.
Current Status
IP 1
Displays the current IP address 1 of the device.
IP 2
Displays the current IP address 2 of the device.
Save
Click
Save
to save the values and update the screen.
Note!
All new configurations will take effect after rebooting. To reboot the
device, click
Tools
>
Reboot
.
Item
Description
Item
Description
Type
Click the drop-down menu to select a serial interface: RS-232,
RS-422 or RS-485.
Baud Rate
Enter a value to specify the baud rate. The value should conform
to the current transmission speeds of connected devices when set-
ting the baud rate.
Parity
Click the drop-down menu to select the parity: None, Odd, Even,
Mark or Space.
Data Bits
Click the drop-down menu to select the data bits: 5, 6, 7, or 8.
Stop Bits
Click the drop-down menu to select the stop bits: 1, 1.5 or 2.
Summary of Contents for EKI-1500-CE Series
Page 1: ...User Manual EKI 1500 CE Series 1 2 4 port RS 232 422 485 Serial Device Servers...
Page 12: ...Chapter 1 1Introduction...
Page 14: ...Chapter 2 2Getting Started...
Page 30: ...Chapter 3 3Utility Configuration...
Page 46: ...Chapter 4 4Selecting An Operating Mode...
Page 54: ...Chapter 5 5Setting up Virtual COM Port...
Page 63: ...Chapter 6 6Web Interface...
Page 82: ...Chapter 7 7Telnet Serial Console Configuration...