4.2  Modbus Setting 

On the Modbus TCP/RTU network side, the gateway will act as a Modbus 

TCP/RTU master. The gateway provides an internal memory for data exchange 

between Modbus TCP/RTU and PROFINET. For each Modbus read/write 

command, specify the internal memory address for data exchange. For the read 

command, the information received from remote slave device will be updated to 

the specified internal memory address. For the write command, the data in the 

specified internal memory address will be sent to the remote slave device. The 

data will be used to update the remote slave device register. 

 

To access this page, click Protocol Setting > Modbus Setting 

 

 

 

Start-up Mode Operation Mode 

The setting is designated the action of all Modbus TCP/RTU commands at 

system start-up stage. Please note that the setting can be selected only 

when Status/Control Word is mapped to the PROFINET I/O area respectively. 

Otherwise, Running mode is the only option. 

Value 

Description 

Running 

The Modbus TCP/RTU master starts to exchange data with 

the slaves as soon as possible after start-up. 

Idle 

The Modbus TCP/RTU master does not exchange any data 

with the slaves and waits for instructions via the control 

Summary of Contents for EKI-1242PNMS

Page 1: ...Protocol Gateway EKI 1242PNMS Quick Guide v1 0 2017 10 26...

Page 2: ...zation Effortless configuration via WEB Dual image Easy backup restore configuration via microSD card Note Device WEB page can be accessed only via Modbus TCP Ethernet port 1 2 Software Specification...

Page 3: ...nd flow control for port configuration To access this page click Serial Setting Port Parameter Description Type Click the drop down menu to select a serial interface RS 232 RS 422 or RS 485 Baud Rate...

Page 4: ...hrough the dedicated control word the scanner on the PROFINET network starts stops the exchange of data on the Modbus TCP RTU network The master on the PROFINET network can see the status of the Modbu...

Page 5: ...de as in the table below The indexes in the exception code list correspond completely to the sequence of the Modbus Commands Byte 0 Byte 1 Byte 2 Byte 63 Exception code for command 0 Exception code fo...

Page 6: ...be sent to the remote slave device The data will be used to update the remote slave device register To access this page click Protocol Setting Modbus Setting Start up Mode Operation Mode The setting...

Page 7: ...To remove Modbus commands select the specific command and then click the Delete button To copy a Modbus command select specific command and then click the Copy button Note The gateway needs to be rest...

Page 8: ...er to a Slave device the function code field tells the slave what kind of action to perform Below are the supported function codes 01 Read coils 02 Read discrete inputs 03 Read holding registers 04 Re...

Page 9: ...e remote Modbus device must return a response to the transaction When PROFINET doesn t exchange I O In I O mapped write transaction when PROFINET does not exchange I O Clear data to Modbus server Tran...

Page 10: ...data Data from the PROFINET network to the Modbus TCP RTU network Control word optional Output data PROFINET I O Table will be mapping to module in Step 7 TIA Portal Index of the Module Size of the Mo...

Page 11: ...ackup Manager The Backup Manager page allows you to backup configuration from gateway or restore configuration file to gateway To access this page click System Management Backup Manager 5 3 Upgrade Ma...

Page 12: ...o access this page click System Management Reset System 5 5 Reboot Device Click Reboot Device button to reboot the gateway Any configuration changes you have made since the last time you issued a appl...

Page 13: ...d system reboot Remember to apply the configuration in order for changes to take effect As soon as you have submitted data to the configuration but not yet applied it you will see the box below at the...

Page 14: ...le start capturing data 7 microSD Card Functionality The EKI 1242PNMS provides user with an easy way to backup copy replacement deployment The gateway is equipped with a microSD card slot User can plu...

Page 15: ...way 2 Pull out the microSD card from manfunctioning gateway and insert the microSD card into the new gateway 3 Power on the new gateway 4 The configuration file stored on the microSD card will automat...

Page 16: ...Do NOT power off the gateway when loading default settings...