39
EKI-122X Series User Manual
3.5.3
Restore to Factory Default Settings
The configuration utility provides the function to restore the serial device server to
factory default settings.
Figure 3.21 Restore to Factory Default Settings
The confirm message will display after clicking
Restore to Factory Default Set-
tings
. If you really want to restore the serial device sever to factory default settings,
click
Yes
button to continue.
Power off the serial device server within ten seconds. After reconnecting the power,
all settings will be reset to the factory default. If the power supply remains connected
for more than ten seconds, the serial device server will not be changed.
3.5.4
Resetting the Device
The
Reset Device
function allows you to reset the serial device server. The function
disconnects both the ethernet and serial connections.
The function also allows the serial device server to save new configuration settings to
flash memory. Once a new setting is changed, you can use the Save function to
accept the changes. You must then reset the device to save the settings to flash
memory.
To access this page, click
Tools
>
Reboot
.
Click
Reboot
to reboot the serial device server. Any configuration changes you have
made since the last time you saved will be lost.