ECU-4784 User Manual
46
B.1
Watchdog Timer Programming
--------------------------------------------------------------
---------------------
Enter the extended function mode, interruptible double-write
--------------------------------------------------------------
--------------------- MOV DX,2EH
MOV AL,87H OUT DX,AL OUT DX,AL
--------------------------------------------------------------
---------------
Configured logical device 8, configuration register CRF6
--------------------------------------------------------------
--------------- MOV DX,2EH
MOV AL,2BH OUT DX,AL MOV DX,2FH IN AL,DX
AND AL.OEFH; Setbit 4=0 Pin 89=WDTO OUT DX,AL
MOV DX,2EH
MOV AL,07H; point to Logical Device Number Reg. OUT DX,AL
MOV DX,2FH
MOV AL,08H; select logical device 8 OUT DX,AL;
MOV DX,2EH
MOV AL,30H;Set watch dog activate or inactivate OUT DX,AL
MOV DX,2FH
MOV AL,01H; 01:activate 00:inactivate OUT DX,AL;
MOV DX,2EH
MOV AL,F5H; Setting counter unit is second OUT DX,AL
MOV DX,2FH MOV AL,00H OUT DX,AL; MOV DX,2EH MOV AL,F6H OUT
DX,AL MOV DX,2FH
MOV AL,05H; Set 5 seconds
OUT DX,AL
;------------------------------------------
; Exit extended function mode
;------------------------------------------ MOV DX,2EH
MOV AL,AAH OUT DX,AL