DLT-V4108 settings
Advantech-DLoG
DLT-V4108 Manual, V01 Prelim
33 / 81
11.3.
MDevice settings: Function keys, power management, etc.
The
MDevice
software is used for configuring general settings of DLT-V4108 devices, for
example:
−
Function key programming
−
Power management (automatic shutdown)
−
Network settings
−
And more
Start MDevice
−
Start
MDevice
via
Start -> Programs -> DLoG: MDevice
.
−
Enter the standard password:
gold
.
You can find details on configuration in the "MDevice Manual” at
11.3.1.
Power management functional description (automatic shutdown)
DLT-V4108 is equipped with an automatic shutdown module.
If wired up accordingly, DLT-V4108 conveniently switches off together with the ignition.
As disconnecting the power supply during operation can lead to data loss, the operating system
needs to be shut down normally by using the appropriate hardware and software installed on the
system when the ignition is switched off.
DLT-V4108 is connected with three supply cables. DC+ and DC- are directly connected to the
power supply, the connection is run through fuses.
The supply voltage is then linked to DLT-V4108’s ignition input via a switch, for example, the key
switch of the ignition (also with a fuse).
Sequence
When the ignition is turned on or DLT-V4108 <Power> button is pressed (depends on
configuration), DLT-V4108 checks its internal temperature and runs a test to confirm that the
automatic shutdown function is working.
If the check of the environmental conditions is successful, DLT-V4108 starts the operating system
normally.
Once these checks are completed, DLT-V4108 starts the operating system.
The environmental conditions (OTP/UTP/Sensor Faulty) are constantly being checked all the
time.
The ignition status is constantly monitored at all times as well.
If DLT-V4108’s internal temperature reaches a critical level, shutdown of the operating system
will be carried out. The computer will remain switched off until the temperature is once again
within the permitted range.
If the ignition input is
grounded or isolated during normal operation of DLT-V4108, the device will
switch to a delayed shut-off state.