VESR9xx Serial Servers
20
To set up a Paired Mode connection:
1. Connect two serial servers to serial devices and to the
network.
Configure the serial server for Paired Mode operation (using
Vlinx Manager or the web interface).
INITIATING A HARDWARE RESET ON THE SERIAL SERVER
To initiate a Hardware Reset on the serial server
, press and hold the
Mode switch for 0 to 2 seconds, and then release it. The LED indicators
respond as follows:
1. The Ready LED blinks three times per second while the
button is being pressed.
The serial server is in Reset Mode when:
•
On VESR901: Port 1 LED is On and the Ready LED is Off.
•
On VESR902D: Port 1 LED is On and the Port 2 LED is Off.
•
The LEDs go back to their normal states when the device
resumes normal operation.
RELOADING FACTORY DEFAULTS
To reload Factory Defaults,
press and hold the Mode switch for more
than 10 seconds. The LED indicators respond as follows:
1. The Ready LED blinks three times per second while the
button is being pressed.
The serial server is in Factory Default Mode when:
•
On VESR901: Port 1 LED and the Ready LED are both On.
•
On VESR902D: Port 1 LED and the Port 2 LED are both On.
•
The serial server reloads all factory default configuration
parameters.
•
The LEDs go back to their normal states when the device
resumes normal operation.
Note: Factor default parameters are listed in Appendix A.
Summary of Contents for BB-VESR9 Series
Page 1: ...Ethernet Serial Servers BB VESR9xx series USER MANUAL...
Page 49: ...VESR9xx Serial Servers 43 Dimensional Diagram of Model VESR902D Serial Server...
Page 50: ...VESR9xx Serial Servers 44 Dimensional Diagram of Model VESR902D Serial Server...
Page 51: ...VESR9xx Serial Servers 45 Dimensional Diagram of Model VESR922T Serial Server...