USING THE RESET SWITCH TO RELOAD FACTORY DEFAULT SETTINGS
Hold the Reset switch for more than ten seconds. The Serial LED illuminates for the first two seconds;
then the Ready LED illuminates. After 10 seconds, both the Serial and Ready LEDs illuminate. Release
the switch after more than 10 seconds. The serial server will reset to factory default settings.
ETHERNET CONNECTOR
The Ethernet connection uses an RJ45 receptacle. The serial server is connected to a standard Ethernet
network drop using a straight-through RJ45 (male) Ethernet cable.
Note: Refer to Appendix D for connection pin-outs.
SERIAL PORT CONNECTORS
BB-VESP211x serial servers feature two serial port connector configurations, depending on the model:
Models BB-VESP211 and BB-VESP211-232 use DB9M connectors for RS-232, RS-422 and RS-485
connections.
Figure 2.4 DB9M Serial Port Connector
Model BB-VESP211-485 serial server uses a five-position, removable terminal block for RS-422 and RS-
485 connections.
Figure 2.5 Five-Position Pluggable Terminal Blocks
Note: Refer to Appendix D for connection pin-outs.