IE-iMcV-2xLIM 

 

 

ABOUT THE IE-IMCV-2XLIM 

 

The IE-iMcV-2xLIM, TX/SFP is a Fast Ethernet module that provides two 

conversions of 100Base-TX twisted pair to 100Base-FX/SX single-mode or multi-

mode fiber. There are two sets of ports, each providing an RJ-45 (copper) to SFP 

(fiber) an SFP,155 Mbps, can be installed in the SFP port.  
 
IE-iMcV-2xLIM, TX/SFP with Configuration Control support allows two 

wavelengths to share one fiber strand -  full-duplex data travels on different 

wavelengths (for example,1310 nm and 1550 nm) - doubling the capacity of fiber.  
 
The IE-iMcV-2xLIM, TX/SFP is SNMP-manageable and can be installed into the 

modular, SNMP-manageable iMediaChassis, the MediaChassis series, or the 

MediaChassis series which are unmanaged. 
 
A single DIP Switch bay offers configuration for each RJ-45 to fiber interface set: 

DSW 1-5 for Port 1 and DSW 6-10 for Port 2. 

 

NOTE

: Some options require items that are sold separately, available from B+B SmartWorx.

 

 

CONFIGURATION INSTRUCTIONS 

 

The IE-iMcV-2xLIM, TX/SFP has user-configurable maintenance features (e.g., 

TX LinkLoss (TXLL), FX LinkLoss (FXLL), Link Fault Pass-Through (LFPT) and 

Far End Fault (FEF)). Refer to the iMcV-Module DIP Switch configuration table 

for information on available features. Instructions for configuring both managed 

(via an SNMP-compatible management application like iView²) and unmanaged 

modules follow.  

 
 

 

Summary of Contents for B+B SmartWorx IE-iMcV-2xLIM

Page 1: ...IE iMcV 2xLIM USER MANUAL...

Page 2: ...tWorx European Headquarters Westlink Commercial Park Oranmore Co Galway Ireland Phone 353 91 792444 Fax 353 91 792445 www advantech bb com B B SMARTWORX TECHNICAL SUPPORT USA Canada 1 800 346 3119 Ott...

Page 3: ...d Modules 6 LED Operation 6 FX LinkLoss TX LinkLoss Link Fault Pass Through Far End Fault 8 Link Integrity 8 FX LinkLoss FXLL 8 TX LinkLoss TXLL 8 Link Fault Pass Through LFPT 9 Far End Fault FEF 9 Au...

Page 4: ...the Radio Interference Regulation of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num r...

Page 5: ...manageable and can be installed into the modular SNMP manageable iMediaChassis the MediaChassis series or the MediaChassis series which are unmanaged A single DIP Switch bay offers configuration for...

Page 6: ...manage one or more iMcV 2xLIM modules an SNMP agent must be present in the chassis To configure managed modules install the module first and then configure using the management software CONFIGURATION...

Page 7: ...start using the Management module s settings When an iMcV module changes from DIP Switch settings to the Management module s settings the traffic across the iMcV modules will be interrupted for a ver...

Page 8: ...FXLL Port A Off 3 TX LinkLoss TXLL Port A Off 4 Far End Fault FEF Port A Off 5 Enable TX Port Port A ON 6 Auto Negotiation AN Port B ON 7 FX LinkLoss FXLL Port B Off 8 TX LinkLoss TXLL Port B Off 9 F...

Page 9: ...the link pulses are reaching the other end The combination of FEF and LinkLoss allows this information to be obtained even when physical access to a remote device and its link integrity LED is not ava...

Page 10: ...nt in the opposite direction indicating the fault When enabling LFPT FXLL will act on this signal propagating the loss of link to the copper port when FXLL is enabled For more information on LinkLoss...

Page 11: ...e Refer to the DIP Switch table for switch location and settings AUTOCROSS FEATURE FOR TWISTED PAIR CONNECTION All twisted pair ports on the IE iMcV 2xLIM TX SFP includes Auto Cross a feature that aut...

Page 12: ...Blinks when a fault occurs on the copper port and actively disables the fiber port LNK ACT Glows green when the fiber or copper link is established Blinks green when activity is detected FEF Glows gr...

Page 13: ...ese steps to test 1 Connect the IE iMcV 2xLIM TX SFP to the twisted pair device with a twisted pair cable 2 Loop a single strand of fiber from the Transmit port to the Receive port of the IE iMcV 2xLI...

Page 14: ...alternate between blasting with clean dry compressed air and flushing with methanol to remove particles of dirt ELECTROSTATIC DISCHARGE PRECAUTIONS Electrostatic discharge ESD can cause damage to any...

Page 15: ...old waste It is the consumer s responsibility to dispose of this and all equipment so marked through designated collection facilities appointed by government or local authorities Following these steps...

Reviews: