Chapter 5: Maintenance
IMPORTANT
: For your own safety and for the safety of the equipment:
l
Do not remove the cover of the XC4
l
Do not attempt to access the internal components.
A fuse that needs to be replaced indicates that there is a more serious problem with the
system or setup. Contact Global Technical Support for assistance.
DANGER
: If you must remove the covers and access any internal components be aware of
the risk of electric shock.
1. Disconnect the Mains power connection.
2. Wait at least ten (10) minutes after removing the power supply before doing main-
tenance or an inspection. Otherwise, there is the danger of electric shock.
3. All tests must be done by an approved service technician. Voltages inside the con-
troller and at the input and output power connections can kill you.
Table 5-1:
LED Description
LED
Color
Description
PWR
GREEN
The light will illuminate and remain illuminated while power is
applied.
EN/FLT
GREEN
The axis is Enabled.
RED
The axis is in a Fault Condition.
GREEN/RED
(alternates)
The axis is Enabled in a Fault Condition.
or
The light is configured to blink for setup.
Table 5-2:
Troubleshooting
Symptom
Possible Cause and Solution
No Communication
Make sure the power LED is illuminated (this indicates that power is present).
Make sure that all communication cables (HyperWire, for example) are fully
inserted in their ports.
XC4 Hardware Manual
Chapter 5: Maintenance
www.aerotech.com
105
Summary of Contents for Automation1 XC4
Page 1: ...Revision 2 01 Automation1 XC4 PWM Digital Drive HARDWARE MANUAL...
Page 12: ...This page intentionally left blank Agency Approvals XC4 Hardware Manual 12 www aerotech com...
Page 24: ...Figure 1 4 Dimensions EB1 1 2 2 Dimensions XC4 Hardware Manual 24 www aerotech com...
Page 71: ...Figure 2 36 PSO Interface XC4 Hardware Manual 2 5 Auxiliary I O Connector www aerotech com 71...
Page 120: ...Index XC4 Hardware Manual This page intentionally left blank 120 www aerotech com...