background image

ARK-2150 User Manual

40

3.3.13

CPU PPM Configuration

Figure 3.16 CPU PPM Configuration

EIST

CPU runs at its default speed if disabled; CPU speed is controlled by the operating
system if enabled.

Turbo Mode

This item allows users to enable or disable turbo mode.

CPU C3/C6/C7 Report

This item allows users to enable or disable CPU C-state support.

Configurable TDP

This item allows users to select TDP levels.

Config TDP LOCK

This item allows users to enable or disable Config TDP LOCK.

ACPI T State

This item allows users to enable or disable ACPI T State.

Summary of Contents for ARK-2150

Page 1: ...User Manual ARK 2150 Fanless Embedded Box PC...

Page 2: ...ontains a hard copy user manual in Chinese for China CCC certifica tion purposes and there is an English user manual included as a PDF file on the CD Please disregard the Chinese hard copy user manual...

Page 3: ...rnational Inc VIA is a trademark of VIA Technologies Inc IBM PC AT PS 2 and VGA are trademarks of International Business Machines Cor poration Intel and Pentium are trademarks of Intel Corporation Mic...

Page 4: ...essages you get when the problem occurs 2 Call your dealer and describe the problem Please have your manual product and any helpful information readily available 3 If your product is diagnosed as defe...

Page 5: ...ny error messages Warnings Cautions and Notes Packing List Before installation please ensure the following items have been shipped 1 x ARK 2150 unit 1 x Driver Utility CD 1 x Registration and 2 years...

Page 6: ...fanless EBC VGA HDMI DVI D 4GbE 3USB3 0 4COM Part Number Description 1757003934 AC to DC Adapter DC 12V 5A 60W 0 40 C for Home and Office Use 1702002600 Power cable 3 pin 180 cm USA type 1702031801 P...

Page 7: ...nings this could cause fire or electrical shock 13 Never open the equipment For safety reasons only qualified service personnel should open the equipment 14 If one of the following situations arises g...

Page 8: ...ARK 2150 User Manual viii...

Page 9: ...escription 10 2 2 2 Jumper List 11 Table 2 1 Jumper List of Main Board 11 2 2 3 Jumper Location 11 Figure 2 1 Jumper layout 11 2 2 4 Jumper Setting 11 Table 2 2 Clear CMOS JP1 11 Table 2 3 Auto Power...

Page 10: ...BIOS Features Setup 27 Figure 3 3 Advanced BIOS features setup screen 28 3 3 1 ACPI Settings 28 Figure 3 4 ACPI Setting 28 3 3 2 CPU Configuration 29 Figure 3 5 CPU Configuration 29 3 3 3 SATA Config...

Page 11: ...el IGFX Configuration 43 Figure 3 21LCD Control 44 3 5 Boot Settings 45 Figure 3 22Boot Setup Utility 45 3 6 Security Setup 46 Figure 3 23Password Configuration 46 3 7 Save Exit 47 Figure 3 24Save Exi...

Page 12: ...ARK 2150 User Manual xii...

Page 13: ...Chapter 1 1 General Introduction This chapter gives background information on ARK 2150 series...

Page 14: ...ed cooling efficiency It also provides rich I O interfaces up to 4 x Intel GbEs 3 x USB 3 0 4ch isolated digital input 4ch isolated digital output and supports high capacity 2 5 HDD up to 1 TB The RS...

Page 15: ...sion Interface Supports 2 x full size Mini PCIe one supports mSATA and the other with SIM holder and 1 x half size Mini PCIe Software API Advantech iManager and SUSIAccess Remote Device Man agement te...

Page 16: ...640 MHz Video Accelera tor HW accelerated Media Decode AVC H 264 VC 1 MPEG 2 HW accelerated Media Encode AVC H 264 MPEG 2 SATA Interface Intel QM77 chip supports Supports several optional sections of...

Page 17: ...OM4 Supports RS 232 422 485 and change mode under BIOS setting COM1 COM4 RS 485 supports Auto flow control COM connector D SUB CON 9P Ethernet LAN1 Intel 82579LM LAN2 Intel 82583V LAN3 Intel 82583V LA...

Page 18: ...pical Isolated Digital Output Number of Channel 4 Optical Isolation 2 500 VDC Output Voltage Open collector 5 to 40 VDC Sink Current 200 mA max channel ARK 2150F 10 pins phoenix connector DIO Connecto...

Page 19: ...6 Unit mm Inch Figure 1 1 ARK 2150 Mechanical dimension drawing 1 4 2 Weight 2 8kg 6 17lb 1 5 Power Requirement 1 5 1 System Power Minimum power input ARK 2150L DC12 V 4 A ARK 2150F DC12 V 24 V 4 A 2...

Page 20: ...ir flow speed 0 7 m sec 1 6 2 Relative Humidity 95 40 C non condensing 1 6 3 Storage Temperature 40 85 C 40 185 F 1 6 4 Vibration during Operation When system is equipped with SSD mSATA 5Grms IEC 6006...

Page 21: ...Chapter 2 2 H W Installation This chapter introduces external IO and the installation of ARK 2150 hardware...

Page 22: ...to connect them To close a jumper you connect the pins with the clip To open a jumper you remove the clip Sometimes a jumper will have three pins labeled 1 2 and 3 In this case you would connect eithe...

Page 23: ...List 2 2 3 Jumper Location Figure 2 1 Jumper layout 2 2 4 Jumper Setting At Mother Board 2 2 4 1 Clear CMOS J1 Table 2 1 Jumper List of Main Board J1 Clear CMOS J2 Auto Power On Setting J4 DDR3L sele...

Page 24: ...el Power Select J4 2 3 Clear CMOS Table 2 2 Clear CMOS JP1 Table 2 3 Auto Power On Setting J2 Setting Function NC Power Button for Power On 1 2 Auto Power On default Table 2 4 LVDS Panel Power Select...

Page 25: ...ARK 2150F Note The numbering of LAN ports under different OS might be different from the IO silk print VGA USB2 USB1 USB4 USB3 HDMI HDD LED PWR LED LAN1 LAN2 LINE IN LINE OUT MIC COM4 COM3 COM2 COM1 D...

Page 26: ...K 2150 is equipped with up to four Ethernet controllers that are fully compliant with IEEE 802 3u 10 100 1000 Mbps CSMA CD standards The Ethernet port pro vides a standard RJ 45 jack connector with LE...

Page 27: ...SUB 9 pin female connector which offers 8 bit digital input output communication without isolation ARK 2150F provides one phoenix 10 pin male connector which offers 4 ch digital input and 4 ch digital...

Page 28: ...its pin assignments USB 3 0 connectors contain legacy pins to interface to USB 2 0 devices and a new set of pins for USB 3 0 connectivity both sets reside in the same connector Figure 2 9 USB3 0 Conne...

Page 29: ...conform to this standard The USB interface supports Plug and Play Figure 2 10 USB2 0 connector 2 3 1 7 VGA Connector The ARK 2150 provides a high resolution VGA interface connected by a D sub 15 pin c...

Page 30: ...Power Input Connector ARK 2150L Figure 2 14 Compatible dimension of DC Plug for ARK 2150L 13 H SYNC 14 V SYNC 15 NC Table 2 13 HDMI Display Port Connector Pin Assignments Pin Signal Name Pin Signal N...

Page 31: ...nd HDD LED is for HDD Cfast flash disk status Figure 2 17 LED Indicators 2 3 1 12 DVI D Connector ARK 2150F only ARK 2150F offers a Digital Visual Interface connector by a D sub 24 pin female DVI D co...

Page 32: ...into the HDD bay on the bottom cover 9 TMDS Data 1 10 TMDS Data 1 11 TMDS Data 1 3 shield 12 TMDS Data 3 13 TMDS Data 3 14 5 V 15 Ground 16 Hot plug detect 17 TMDS data 0 18 TMDS data 0 19 TMDS data...

Page 33: ...ion 3 Screw the four screws on the side of HDD bracket The screws are used to fix the HDD on the bracket The screws are in the accessory box 4 Recover the bottom cover and screws 2 4 2 Memory Installa...

Page 34: ...ARK 2150 User Manual 22 2 Unscrew the four screws on the right and left side of top cover 3 Remove the top cover 4 Install DDR3 memory in to the system 5 Recover the top chassis...

Page 35: ...Installation 2 4 3 MiniPCIe module and mSATA Installation 1 Unscrew the four screws on the top cover 2 Install ARK 2150L miniPCIe module or mSATA into the socket full size miniPCIe mSATA or full size...

Page 36: ...2150 User Manual 24 3 Install ARK 2150F miniPCIe module or mSATA into the socket 4 Recover the bottom cover and screws Full size miniPCIe with SIM mSATA or full size miniPCIe Half size miniPCIe ARK 21...

Page 37: ...Chapter 3 3 BIOS Settings...

Page 38: ...up program that allows users to modify the basic system configuration This information is stored in flash ROM so it retains the Setup information when the power is turned off 3 1 Entering Setup Turn o...

Page 39: ...Highlight System Time or Sys tem Date using the Arrow keys Enter new values through the keyboard Press the Tab key or the Arrow keys to move between fields The date must be entered in MM DD YY format...

Page 40: ...User Manual 28 Figure 3 3 Advanced BIOS features setup screen 3 3 1 ACPI Settings Figure 3 4 ACPI Setting Enable ACPI Auto Configuration This item allows users to enable or disable BIOS ACPI auto conf...

Page 41: ...ration Hyper Threading Technology This item allows users to enable or disable Intel Hyper Threading technology Active Processor Cores This item allows users to set how many processor cores should be a...

Page 42: ...enable or disable the adjacent cache line prefetch feature 3 3 3 SATA Configuration Figure 3 6 SATA Configuration SATA Controller s This item allows users to enable or disable the SATA controller s S...

Page 43: ...PCH FW Configuration Figure 3 7 PCH FW Configuration MDES BIOS Status Code This item allows users to enable or disable MDES BIOS Status Code function Firmware Update Configuration This item allows use...

Page 44: ...onfigure ME without password confirmation prompt MEBx Debug Message Output This item allows users to enable or disable MEBx debug message Un Configure ME This item allows users to un configure ME with...

Page 45: ...er Set BIOS watchdog timer 3 3 6 USB Configuration Figure 3 9 USB Configuration Legacy USB Support Enable the support for legacy USB Auto option disables legacy support if no USB devices are connected...

Page 46: ...up delay Set the maximum time of the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken fr...

Page 47: ...8 1 Serial Port 1 Configuration Serial Port This item allows users to enable or disable COM1 Change Settings This item allows users to select super I O device 3 3 8 2 Serial Port 2 Configuration Seri...

Page 48: ...ce Device Mode This item allows users to select Serial Port mode Serial interface This item allows users to select RS 232 422 485 Default by RS 232 3 3 9 2 Serial Port 4 Configuration Serial Port This...

Page 49: ...2150 User Manual Chapter 3 BIOS Settings 3 3 10 Platform Misc Configuration Figure 3 13 Platform Misc Configuration Native PCIE Enable This item allows users to enable or disable native PCIE support f...

Page 50: ...Embedded Controller Configuration Backlight Enable Polarity This item allows users to set backlight Function Power Saving Mode This item allows users to select ITE8518 power saving mode H W Monitor T...

Page 51: ...ion Figure 3 15 Serial Port Console Redirection Console Redirection This item allows users to enable or disable console redirection for Microsoft Windows Emergency Management Serivces EMS Console Redi...

Page 52: ...system if enabled Turbo Mode This item allows users to enable or disable turbo mode CPU C3 C6 C7 Report This item allows users to enable or disable CPU C state support Configurable TDP This item allow...

Page 53: ...ARK 2150 setup screen to enter the Chipset BIOS Setup screen You can display a Chipset BIOS Setup option by highlight ing it using the Arrow keys All Plug and Play BIOS Setup options are described in...

Page 54: ...oller PCIE Wake from S5 PCIE wake Enables or disables from S5 state MINI Card M SATA This item allows users to select MINI card or M SATA function WiFi Card1 WiFi Card 2 This item allows users to enab...

Page 55: ...hapter 3 BIOS Settings This item allows users to select off on and last state 3 4 2 System Agent SA Configuration Figure 3 19 System Agent SA Configuration 3 4 2 1 Intel IGFX Configuration Figure 3 20...

Page 56: ...e Gfx Low Power Mode This item allows users to enable or disable IGD low power mode Graphics Performance Analyzers This item allows users to enable or disable Graphics Performance Analyzers LCD Contro...

Page 57: ...f seconds to wait for setup activation key Bootup NumLock State Select the Power on state for Numlock Quiet Boot If this option is set to Disabled the BIOS displays normal POST messages If Enabled an...

Page 58: ...50 Setup main BIOS setup menu All Security Setup options such as password protection is described in this section To access the sub menu for the following items select the item and press Enter Change...

Page 59: ...BIOS setup menu and reboot the computer to take effect all system configuration parameters Discard Changes and Reset Select this option to quit Setup without making any permanent changes to the syste...

Page 60: ...experiencing system configuration problems Save User Defaults When users have completed system configuration select this option to save changes as user defaults without exit BIOS setup menu Restore U...

Page 61: ...Appendix A A Watchdog Timer Sample Code...

Page 62: ...v dx EC_Command_Port mov al 89h Write EC HW ram out dx al mov dx EC_Command_Port mov al 5Fh Watchdog reset delay time low byte 5Eh is high byte index out dx al mov dx EC_Data_Port mov al 30h Set 3 sec...

Page 63: ...51 ARK 2150 User Manual Appendix A Watchdog Timer Sample Code...

Page 64: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Reviews: