background image

AMAX-4817/4820 Startup Manual  3

  LEDs

 

Power Indicator

Indicator State

System State

Description

Off

Power off

The system is not on/

power is off.

On

Power on

The system is on/

power is on.

Run Indicator

Indicator State

SubDevice 

State

Condition

Off

Initialization

The device is in the 

Initialization state.

Blinking

Pre-Opera-

tional

The device is in the 

Pre-Operational state.

Single flash

Safe Opera-

tional

The device is in the 

Safe Operational 

state.

On

Operational

The device is in the 

Operational state.

Flickering

Bootstrap

The device is booting 

and has not yet en-

tered the Initialization 

state/the device is in 

the Bootstrap state/

a firmware download 

is in progress.

Error Indicator

Indicator State

Error Name

Description

Off

No error

The device is in work-

ing condition.

Blinking

Invalid configu

-

ration

General configuration 

error.

Single flash

Local error

A SubDevice device 

application has 

changed the EtherCAT 

state autonomously 

due to local error/

the error indicator bit 

is set to 1 in the AL 

Status register.

Double flash

Watchdog 

timeout

An application 

watchdog timeout has 

occurred.

Link Indicator (on RJ-45)

Indicator State Link Activity

Description

On

Yes

No

Port open/connected

Flickering

Yes

Yes

Port open/connected

Off

No

Not 

applicable

Port closed/discon-

nected

  

Dimensions

 

Summary of Contents for AMAX-4817

Page 1: ... ensure easy installation in cabinets The modules also feature euro type pluggable terminal blocks and LED in dicators that facilitate system setup and maintenance All modules are equipped with an isolation circuit that ensures current protection for demanding industrial applications General Connectors N x 10 pin terminal block 3 81 mm AMAX 4817 N 2 AMAX 4820 N 1 2 x 3 pin screw terminal block 3 8...

Page 2: ...SubDevice ID range 0 255 For example if a user arranges the rotary switches follow ing the sequence 4 F the SubDevice ID will be set as 4 x 16 F x 1 79 AMAX 4817 4820 modules feature two power input terminals an input power range of 10 to 30 VDC and power redundan cy support For modules connected to two power input sourc es if one source is inactive or interrupted the other power source can take o...

Page 3: ...ing and has not yet en tered the Initialization state the device is in the Bootstrap state a firmware download is in progress Error Indicator Indicator State Error Name Description Off No error The device is in work ing condition Blinking Invalid configu ration General configuration error Single flash Local error A SubDevice device application has changed the EtherCAT state autonomously due to loc...

Page 4: ...log Input Connection Differential Inputs The AMAX 4817 provides eight differential analog input channels Analog Output Connection Single Outputs The AMAX 4820 provides four single ended analog output channels Connections Connections Cont ...