AMAX-3245 User Manual
10
LINKO & LINK1 LED (Green)
Run LED (Green)
Err LED (Red)
STS LED (Green)
2.2.7.2
Running
LED Status
Connection Status
Activation
Trigger Requirements
Last
Yes
No
Port On / Connection
Flash
Yes
Yes
Port On / Connection
Off
No
No
Port Off / Disconnection
LED Status
Salve Module Status
Requirements
Off
INITIALISATION
The device in initialization
Slow Flash
PRE-OPERATIONAL
The device in pre-operation
Single Flash
SAFE-OPERATIONAL
The device in safe-operation
Last
OPERATIONAL
The device in normal operation.
Quick Flash
BOOTSTRAP
The device boots states
1.
The device is starting up and
doesn’t begin initialization.
2.
The device is upgrading firm-
ware.
LED Status
Error Description
Description
Reasons
Off
Correct
Salve module in
normal running
Quick Flash
Wrong Configuration
Wrong salve mod-
ule configuration
1.
Wrong packet parame-
ters of EtherCAT cause
wrong salve module sta-
tus.
2.
Control chip in salve
module detects wrong
hardware configuration.
Single Flash
Wrong salve module
Status switch
caused by mistakes
Synchronization errors cause
salve module turn from 0P to
Safe0P status.
Double Flash
Data processing or
EtherCAT watchdog
timer overtime
Watchdog timer
overtime
Watchdog in Sync Manger over-
time
LED Status
Description
OFF
Power supply disconnection
Flash
The device in normal operation
LED
Axis
Name
Description
D7/10/13/16
Axis 0-4
ORG
Home
D8/11/14/17
Axis 0-4
LMT+
Limit+
D9/12/15/18
Axis 0-4
LMT-
Limit-
Summary of Contents for AMAX-3245
Page 1: ...User Manual AMAX 3245...
Page 6: ...AMAX 3245 User Manual vi...
Page 7: ...Chapter 1 1 Introduction...
Page 11: ...Chapter 2 2 Hardware Wiring...
Page 12: ...AMAX 3245 User Manual 6 2 1 Dimensions 2 1 1 Top view 2 1 2 Front View 2 1 3 Side View...
Page 17: ...Chapter 3 3 Hardware Wiring...
Page 23: ...17 AMAX 3245 User Manual Chapter 3 Hardware Wiring...