![Advantech AMAX-175 Series User Manual Download Page 16](http://html1.mh-extra.com/html/advantech/amax-175-series/amax-175-series_user-manual_2856833016.webp)
AMAX-175x Series User Manual
10
2.4
Board ID Switch (SW1)
Note: Node Number=8xDN3+4xDN2+2xDN1+DN0.
Default Setting: All the switches are in OFF status.
2.5
Configuration Setting (SW2)
2.5.1
Baud-Rate Setting
2.5.2
TUD
This terminal is used to set output conditions when the watchdog timer times out.
Pin
Label
ON
OFF
1
DN5
1
0
2
DN4
1
0
3
DN3
1
0
4
DN2
1
0
5
DN1
1
0
6
DN0
1
0
Switch
Label
Description
1
SPD1
Baud-Rate Setting
2
SPD0
3
TUD
Time-Out Status Latch
4
TMD
Specify watchdog timer time
5
BRK
*For internal use only, please keep in OFF
6
N/A
SPD1
SPD0
OFF
OFF
20 MHz
OFF
ON
10 MHz
ON
OFF
5 MHz
ON
ON
2.5 MHz
OFF
The output keeps its current status.
ON
The output is Reset.