background image

User Manual

ADAM-6100EI Series

EtherNet/IP I/O Modules

Summary of Contents for ADAM-6100EI Series

Page 1: ...User Manual ADAM 6100EI Series EtherNet IP I O Modules...

Page 2: ...llation Advantech assumes no liability under the terms of this warranty as a consequence of such events Because of Advantech s high quality control standards and rigorous testing most of our customers...

Page 3: ...h case the user will be required to correct the interference at his own expense Technical Support and Assistance 1 Visit the Advantech web site at www advantech com support where you can find the late...

Page 4: ...y liquid into an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the foll...

Page 5: ...Overview 8 Figure 2 1 ADAM 6150EI 8 Figure 2 2 ADAM 6151EI 8 Figure 2 3 ADAM 6156EI 9 2 1 2 Specifications 9 2 1 3 Switch Settings 10 2 1 4 Application Wiring 11 2 2 Relay Modules 13 2 2 1 Overview 13...

Page 6: ...ADAM 6100EI Series User Manual vi...

Page 7: ...Chapter 1 1 Overview...

Page 8: ...DIP switch on the side of ADAM module Refer to Section 1 3 3 for how to configure it When you configure the mode as Initial mode you can configure ADAM 6100EI module s IP address and related setting b...

Page 9: ...daisy chain connections in an Ethernet network making it easier to deploy and helping improve scalability The two Ether net ports are fully compliant with IEEE 802 3u 10 100Mbpst through standard RJ 4...

Page 10: ...module as Initial mode or Normal mode by the DIP switch in the side of each module When ADAM 6100EI module is set as Initial mode you can use ADAM Net utility to configure and test the module via Eth...

Page 11: ...any network the Status LED and the COM LED will keep ON Once the module is connected the Status LED and COM LED will work according to the table below Status of the module Mode Status LED Green COM LE...

Page 12: ...ADAM 6100EI Series User Manual 6...

Page 13: ...Chapter 2 2 Product Specifications...

Page 14: ...support the EtherNet IP protocol According to the channel number dif ference you can choose the best digital I O modules for your application ADAM 6150EI 8 ch isolated digital input and 7 ch isolated...

Page 15: ...1EI 16 Dry Contact Switch ON Logic level 0 Open Logic level 1 Close to DGND Wet Contact Switch OFF Logic level 0 0 3 VDC or 0 3VDC Logic level 1 10 30 VDC or 10 30 VDC Input Impedance 10 k Transition...

Page 16: ...dity 0 95 RH non condensing Operating Temperature 10 70 C Storage Temperature 20 80 C 2 1 3 Switch Settings ADAM 6150EI ADAM 6151EI Switch SW1 SW2 Position 1 2 3 4 1 2 3 4 DI Channel Ch3 Ch2 Ch1 Ch0 C...

Page 17: ...11 ADAM 6100EI Series User Manual Chapter 2 Product Specifications 2 1 4 Application Wiring Isolated Digital Input Dry Contact Isolated Digital Input Wet Contact...

Page 18: ...ADAM 6100EI Series User Manual 12 Isolated Digital Output ADAM 6150EI Isolated Digital Output ADAM 6156EI...

Page 19: ...nt for ON OFF control or low power switching applications in an EtherNet IP system ADAM 6160EI 6 ch Relay Module Figure 2 4 ADAM 6160EI 2 2 2 Specifications Relay Channels 5 Form C and 1 Form A B sele...

Page 20: ...on 3 5 W 24 VDC Power Reversal Protection 30V Max Operating Humidity 20 95 RH non condensing Storage Humidity 0 95 RH non condensing Operating Temperature 10 70 C Storage Temperature 20 80 C 2 2 3 Jum...

Page 21: ...e configured to an individual range for a variety of applications Figure 2 5 ADAM 6117EI 2 3 1 2 Specifications Analog Input Channels 8 Differential Input Impedance Voltage 10 M Current 120 Input Type...

Page 22: ...erNet IP Power Input Unregulated 10 30 VDC Power Consumption 3 W max 24 VDC Power Reversal Protection 30V max Operating Humidity 20 95 RH non condensing Storage Humidity 0 95 RH non condensing Operati...

Page 23: ...strial control applications Figure 2 6 ADAM 6118EI 2 3 2 2 Specifications Analog Input Channels 7 Differential Input Impedance Voltage 10 M Current 120 Input Type V mV mA thermocouple Temperature Rang...

Page 24: ...non condensing Storage Humidity 0 95 RH non condensing Operating Temperature 10 70 C Storage Temperature 20 80 C 2 3 2 3 Switch Settings SW1 SW4 Set input mode of each AI channel Temperature Voltage C...

Page 25: ...19 ADAM 6100EI Series User Manual Chapter 2 Product Specifications 2 3 2 4 Application Wiring...

Page 26: ...and current outputs which makes it an ideal output control solution Figure 2 7 ADAM 6124EI 2 3 3 2 Specifications Analog Output Channels 4 Output Type V mA Voltage Current Range 5V 10V 5V 10V 0 20mA 4...

Page 27: ...100 Base T Ethernet Supported Protocol Ethernet IP Power Input Unregulated 10 30 VDC Power Consumption 3 W max 24 VDC Power Reversal Protection 30V max Operating Humidity 20 95 RH non condensing Stora...

Page 28: ...ADAM 6100EI Series User Manual 22...