Mounting by electronic and mechanical skilled persons

Quickstart  

DLT-U1100

2

Important notes

Personal injury

Explosion hazard

The following icons are used in this quick start guide to indicate dangers:

NOTICE    Risk of physical damage

3

Technical data

Battery

Lithium-ion battery

Bridging time

10 min

Maximum output 

40 W

Nominal output voltage of the UPS

12 VDC

Nominal input voltage of the UPS

12, 24, 48 VDC

Input voltage range

9 to 60 VDC

Output voltage range

10 to 14 VDC

Charging time

2,5 h (fully recharge a completely discharged battery)

Connector input

Lumberg 0315 04-Pin male

Connector output

Lumberg 0305 04-Pin female

Qualifications required for mounting of the UPS DLT-U1100
This Quickstart Poster will show you how to perform the mechanical and electrical mounting 

of the Uninterruptible Power Supply (UPS) DLT-U1100. It is intended for skilled persons.

WARNING: Electric shock due to contact with live parts / property damage

•  Only electronic and mechanical skilled persons are permitted to install the  

   DLT-U1100. Specialized knowledge of batteries and the applicable safety  

   regulations is also required.
•  Unauthorized persons must be kept away from the UPS which contains  

   rechargeable Lithium Ion batteries.
•  If the DLT-U1100 is incorrectly installed and configured, the DLoG GmbH warranty 

   for this device will be canceled. 
•  DLoG GmbH assumes no liability for damages caused directly or indirectly  

   by the incorrect installation or usage of the DLT-U1100.
•  DLT-U1100 operators must be trained.

Current manuals on the internet
The current DLT-U1100 manuals can always be found in our Download Center 

on the internet 

www.advantech-dlog.com

 (

Download

 menu).

Intended use
The DLT-U1100 is a battery-operated uninterruptible power supply for the Advantech-DLoG 

industrial PCs MTC 6 and XMT 5, each with 12/24 VDC power supply unit.

If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down automati-

cally via vehicle ignition.

NOTICE: No combination of UPS + automatic start/shut down via ignition 

possible
MTC 6 and XMT 5 can be used with automatic startup/shut down capabilities.  

This automatic feature controls the startup and shutdown of the industrial PC  

via the <POWER> button or the vehicle’s ignition.
If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down via 

vehicle ignition
Hence it is important to make the following setting before the DLT-U1100 is connected 

to MTC 6 and XMT 5: 

•  Define that the MTC 6 and XMT 5 always start and shut down with the  

   <POWER> button, not via ignition signal.
•  Make the respective adjustments in the configuration tools: 

   “DLoG Config“ for MTC 6, “DLoG NextConfig“ for XMT 5

Otherwise, MTC 6 and XMT 5 can not be started, because with a connected UPS 

system no ignition signal is available.

WARNING: Vehicle “EMERGENCY Stop Switch” cannot switch off industrial 

PCs with UPS
If an MTC 6 or XMT 5 industrial PC with an uninterruptible power supply (UPS) is  

installed on a vehicle, the vehicle emergency stop switch will not affect the the  

industrial PC.

WARNING: Explosion hazard

•  Do not use the DLT-U1100 at locations where flammable gases or vapors are 

   present.
•  Do not use the DLT-U1100 near gas stations, fuel depots, chemical facilities or 

   locations where blasting work is being performed.
•  Do not throw the DLT-U1100 into fire; the batteries may explode.

WARNING: Electrical shock possible from touching live parts / property damage

•  Do not commission the DLT-U1100 if there are visible signs of damage to the 

   device.
•  The DLT-U1100 contains Lithium Ion batteries. Replacement of the rechargeable 

   batteries by the customer is expressly prohibited.
•  Do not open or modify the DLT-U1100.
•  Do not perform any repairs. Repairs on the DLT-U1100 may be made only by 

   Service Centers authorized by Advantech-DLoG.
•  Do not submerge the DLT-U1100 and cables in water or other liquids because of 

   the danger of electrical shock.
•  Use only original power cables by Advantech-DLoG; they meet special  

   requirements for low-temperature flexibility, UV resistance, oil resistance, etc.
•  Condensation can occur if the DLT-U1100 is moved from a cold environment into  

   a work room. Therefore, allow for an acclimatization time of approx. 2 hours.

Temperature range, in which the UPS supplies 

the industrial PC with power from the battery

-10 to +50 °C  (+14 to +122 °F)

Temperature range, in which the batteries  

of the UPS are recharged

0 to +45 °C  (+32 to +113 °F)

Storage temperature range

-20 to +60 °C  (-4 to +140 °F)

Vibration/shock

Class 5M3 according to DIN EN 60721-3-5

IP protection

IP65

Weight

1.1 kg

Warranty DLT-U1100 device (batteries  

excluded)

As specified in Advantech-DLoG TOB

Warranty batteries

Six (6) months from delivery

Any other or additional use is not as intended. 

The user/operator of the DLT-U1100 is solely respon-

sible for any resulting damage. This also applies to 

unauthorized modifications to the unit.