1
Mounting by electronic and mechanical skilled persons
Quickstart
DLT-U1100
2
Important notes
Personal injury
Explosion hazard
The following icons are used in this quick start guide to indicate dangers:
NOTICE Risk of physical damage
3
Technical data
Battery
Lithium-ion battery
Bridging time
10 min
Maximum output
40 W
Nominal output voltage of the UPS
12 VDC
Nominal input voltage of the UPS
12, 24, 48 VDC
Input voltage range
9 to 60 VDC
Output voltage range
10 to 14 VDC
Charging time
2,5 h (fully recharge a completely discharged battery)
Connector input
Lumberg 0315 04-Pin male
Connector output
Lumberg 0305 04-Pin female
Qualifications required for mounting of the UPS DLT-U1100
This Quickstart Poster will show you how to perform the mechanical and electrical mounting
of the Uninterruptible Power Supply (UPS) DLT-U1100. It is intended for skilled persons.
WARNING: Electric shock due to contact with live parts / property damage
• Only electronic and mechanical skilled persons are permitted to install the
DLT-U1100. Specialized knowledge of batteries and the applicable safety
regulations is also required.
• Unauthorized persons must be kept away from the UPS which contains
rechargeable Lithium Ion batteries.
• If the DLT-U1100 is incorrectly installed and configured, the DLoG GmbH warranty
for this device will be canceled.
• DLoG GmbH assumes no liability for damages caused directly or indirectly
by the incorrect installation or usage of the DLT-U1100.
• DLT-U1100 operators must be trained.
Current manuals on the internet
The current DLT-U1100 manuals can always be found in our Download Center
on the internet
www.advantech-dlog.com
(
Download
menu).
Intended use
The DLT-U1100 is a battery-operated uninterruptible power supply for the Advantech-DLoG
industrial PCs MTC 6 and XMT 5, each with 12/24 VDC power supply unit.
If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down automati-
cally via vehicle ignition.
NOTICE: No combination of UPS + automatic start/shut down via ignition
possible
MTC 6 and XMT 5 can be used with automatic startup/shut down capabilities.
This automatic feature controls the startup and shutdown of the industrial PC
via the <POWER> button or the vehicle’s ignition.
If the DLT-U1100 is connected, MTC 6 and XMT 5 cannot be started or shut down via
vehicle ignition
Hence it is important to make the following setting before the DLT-U1100 is connected
to MTC 6 and XMT 5:
• Define that the MTC 6 and XMT 5 always start and shut down with the
<POWER> button, not via ignition signal.
• Make the respective adjustments in the configuration tools:
“DLoG Config“ for MTC 6, “DLoG NextConfig“ for XMT 5
Otherwise, MTC 6 and XMT 5 can not be started, because with a connected UPS
system no ignition signal is available.
WARNING: Vehicle “EMERGENCY Stop Switch” cannot switch off industrial
PCs with UPS
If an MTC 6 or XMT 5 industrial PC with an uninterruptible power supply (UPS) is
installed on a vehicle, the vehicle emergency stop switch will not affect the the
industrial PC.
WARNING: Explosion hazard
• Do not use the DLT-U1100 at locations where flammable gases or vapors are
present.
• Do not use the DLT-U1100 near gas stations, fuel depots, chemical facilities or
locations where blasting work is being performed.
• Do not throw the DLT-U1100 into fire; the batteries may explode.
WARNING: Electrical shock possible from touching live parts / property damage
• Do not commission the DLT-U1100 if there are visible signs of damage to the
device.
• The DLT-U1100 contains Lithium Ion batteries. Replacement of the rechargeable
batteries by the customer is expressly prohibited.
• Do not open or modify the DLT-U1100.
• Do not perform any repairs. Repairs on the DLT-U1100 may be made only by
Service Centers authorized by Advantech-DLoG.
• Do not submerge the DLT-U1100 and cables in water or other liquids because of
the danger of electrical shock.
• Use only original power cables by Advantech-DLoG; they meet special
requirements for low-temperature flexibility, UV resistance, oil resistance, etc.
• Condensation can occur if the DLT-U1100 is moved from a cold environment into
a work room. Therefore, allow for an acclimatization time of approx. 2 hours.
Temperature range, in which the UPS supplies
the industrial PC with power from the battery
-10 to +50 °C (+14 to +122 °F)
Temperature range, in which the batteries
of the UPS are recharged
0 to +45 °C (+32 to +113 °F)
Storage temperature range
-20 to +60 °C (-4 to +140 °F)
Vibration/shock
Class 5M3 according to DIN EN 60721-3-5
IP protection
IP65
Weight
1.1 kg
Warranty DLT-U1100 device (batteries
excluded)
As specified in Advantech-DLoG TOB
Warranty batteries
Six (6) months from delivery
Any other or additional use is not as intended.
The user/operator of the DLT-U1100 is solely respon-
sible for any resulting damage. This also applies to
unauthorized modifications to the unit.