Plumbing
To facilitate servicing of pump and to allow for indoor storage during the winter
months, installing union connections at the suction and outlet ports is recommended.
Use Teflon tape to seal threaded connections on molded plastic components. All
plastic fittings must be new or thoroughly cleaned before use.
NOTE: Do NOT use
Plumber’s Pipe Dope as it may cause cracking of the plastic components.
When applying
Teflon tape
to plastic threads, wrap the entire threaded portion of the
male fitting with one to two layers of tape. Wind the tape clockwise as you face the
open end of the fitting, beginning at the end of the fitting.
The pump suction and outlet ports have molded-in thread stops. Do
NOT
attempt to
force hose connector fitting past this stop. It is only necessary to tighten fittings
enough to prevent leakage. Tighten fitting by hand and then use a tool to engage
fitting an additional 1-1/2 turns. Use care when using Teflon tape as friction is
reduced considerably; do NOT over-tighten fitting or you may cause damage. If leaks
occur, remove connector, clean off old Teflon tape, rewrap with one to two additional
layers of Teflon tape, and re-install connector.
Electrical
WARNING – Ground motor before connecting to electrical
power supply. Failure to ground pump motor can cause serious or
fatal electrical shock hazard.
WARNING – Do NOT ground to a gas supply line.
WARNING – To avoid dangerous or fatal electrical shock, turn
OFF power to motor before working on electrical connections.
WARNING – Ground Fault Circuit Interrupter (GFCI) tripping indicates
electrical problem. If GFCI trips and won't reset, consult electrician to inspect
and repair electrical system.
WARNING – Fire Hazard. Match supply voltage to motor nameplate voltage.
Insure that the electrical supply available agrees with the motor's voltage, phase, and
cycle, and that the wire size is adequate for the H.P. (KW) rating and distance from
the power source.
NOTE: All electrical wiring MUST be performed by a qualified professional, and
MUST conform to local codes and regulations.
warning
5
INSTALLATION INSTRUCTIONS
(CONT.)