S
WITCH
I
NSTALLATION
45
By connecting the ground terminal by drain wire to earth ground the switch and chassis can
be ground.
2.6.4 Wiring a Relay Contact
The following section details the wiring of the relay output. The terminal block on the EKI-
5000 Series is wired and then installed onto the terminal receptor located on the EKI-5000
Series.
Figure 2-14.
Terminal Receptor: Relay Contact
The terminal receptor includes a total of six pins: two for PWR1, two for PWR2 and two for a
fault circuit.
2.6.5 Wiring the Power Inputs
There are two power inputs for normal and redundant power configurations. The power
input 2 is used for wiring a redundant power configuration. See the following for terminal
block connector views.
Figure 2-15.
Terminal Receptor: Power Input Contacts
Before applying power to the grounded switch, it is advisable to use a volt meter to
ensure there is no voltage difference between the power supply’s negative output
terminal and the grounding point on the switch.
Do not disconnect modules or cabling unless the power is first switched off.
The device only supports the voltage outlined in the type plate. Do not use any
other power components except those specifically designated for the switch device.
P
OWER
DOWN
AND
DISCONNECT
THE
POWER
CORD
BEFORE
SERVICING
OR
WIRING
THE
SWITCH
.
P-Fail
V2-
PWR2
DC 12-48V
1A@24V PWR1
V2+
V1- V1+
P-Fail
V2-
PWR2
DC 12-48V
1A@24V PWR1
V2+
V1- V1+