Installation and Operation Manual S400 series
13
- 13 -
To activate the simulation mode:
Press
menu
for 2 seconds, then again on
menu
until the simulation
page « SIM » is displayed, then press
to switch "ON" and
to switch "OFF".
Press
to exit setup mode or automatic timeout after 10
seconds.
2.4.6. Key beeps
The key beeps can be activated or deactivated.
To activate or deactivate the key beeps:
Press
menu
for 2 seconds, then again on
menu
until the beep page
"bIP" is displayed, then press
to switch "ON" and
to
switch "OFF".
Press
to exit setup mode, or automatic timeout after 10
seconds.
2.4.7. Resetting data in the memory
At any time, the memory of the display can be returned to factory settings. To do
so, a memory reset command is accessible in the menu.
The following parameters are restored in the memory:
Anemometer unit:
Knots
Wind indicator and anemometer filtering:
10 seconds
Wind calibration coefficient:
slope at 1
Gauge calibration coefficient:
Offset to 0
Wind and battery alarms:
deactivated, threshold at 0
Wind indicator angle (180/360):
0/180° port, starboard
Simulation mode:
deactivated
Backlighting level:
0 (OFF)
To reset the memory:
Press
menu
for 2 seconds, then again on
menu
until the reset
page "RSt" is displayed, then press
or
to activate
the reset.
Press
to exit setup mode, or automatic timeout after 10
seconds.