1.1  Installation Approvals 

1.1.1  Fire System Installations 

The panel must be installed and configured for operation in accordance with these instructions and the 
applicable code of practice or national standard regulations for fire systems installation (for example BS5839-1: 
2002) appropriate to the country and location of the installation.  

1.1.2  Wiring Regulations 

The panel and system must be installed in accordance with these instructions and the applicable wiring codes 
and regulations (for example BS7671) appropriate to the country and location of the installation. 

 

 

 

Summary of Contents for MxPro 4 4100S

Page 1: ...www advancedco com 4100S The operation and functions described in this manual are available from Software Version 4100S 023 013 onwards...

Page 2: ...evices per Loop Apollo 126 detector call points per loop max Hochiki 127 detector call points per loop max Loop Current 2 max Loop 400mA quiescent 500mA alarm Protocols Apollo S90 XP95 Discovery Explo...

Page 3: ...egulations 5 2 INSTALLATION 6 2 1 IDENTIFICATION OF PARTS 6 2 2 INSTALLING THE ENCLOSURE 6 2 2 1 Removing and Replacing the Enclosure Cover 6 2 2 2 Removing the Chassis 6 2 2 3 Mounting the Enclosure...

Page 4: ...TION OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC SENSITIVE DEVICES This equipment is constructed with static sensitive components Observe anti static precautions at all times when handling printed...

Page 5: ...code of practice or national standard regulations for fire systems installation for example BS5839 1 2002 appropriate to the country and location of the installation 1 1 2 Wiring Regulations The panel...

Page 6: ...ys ensure that the earth lead spade terminal is securely seated onto the blade terminal in the back box 2 2 2 Removing the Chassis It is recommended that the chassis be removed before fitting the pane...

Page 7: ...4 17 Cable Tie Anchor Points x6 Earth Studs x2 Enclosure Size and Fixing Point Dimensions 2 2 4 Remounting the Chassis Carefully replace the chassis and fix into place using the two screws Reconnect t...

Page 8: ...scent Alarm Ahr x 1 256 Battery De rating factor Ahr 3 Use the detector manufacturers technical information to calculate the load on the loop for both the quiescent condition and fire alarm condition...