1.3  Installing the Mxp-008 in the Mx-4200/Mx-4400/Mx-4800 

1.3.1  Mounting the Card 

 
 
 

 

Base Card 

M3 Fixing 
Screws 

TB3 

  

Mxp-008 

 

The card mounts on 4 pillars in the top left hand corner of the 
control panel chassis adjacent to the Mx4200/Mx 4400 base card. 

See diagram opposite. 

Use the four M3 screws supplied to securely affix the card to the 
chassis. 

It is not possible to install the Mxp-008 in this position if either the 
Mxp-021 Sounder Splitter or the Mxp-028 Modem is already 
installed. 

1.3.2  Internal Wiring 

Use the supplied 10-way single in line ribbon cable to connect the 

relay card, via the latched header 

– PL1, to the adjacent 10-way 

latched header on the base card. 

 

1.4  External Wiring 

 

The picture below shows the terminal block 
positions for each relay output. 

Relay positions 1 and 2 provide NO / NC 
changeover contacts. Relay positions 3 

– 8 

provide NO contacts only (Mxp-008 Only). 

Install cables suitable for the application and 
degree of fire protection required. These circuits 
are SELV type.  

If additional knockouts are required on the Mx-
4200 or Mx-4400 then use the deeper back box 
(Mxm-020) or use the Termination Enclosures 
(Mxm-028 or Mxm-029) as appropriate. 

 

RELAY 

1

 

RELAY 

2

 

RELAY 

3

 

RELAY 

4

 

RELAY 

5

 

RELAY 

6

 

RELAY 

7

 

RELAY 

8

 

COM

 

NC

 

NO

 

COM

 

NC

 

NO

 

COM

 

NO

 

COM

 

NO

 

COM

 

NO

 

COM

 

NO

 

COM

 

NO

 

COM

 

NO

 

 

All electrical wiring installation work should be carried out in 
accordance with the code of practice applicable in the 
country of installation. 

To maintain electrical integrity of the SELV wiring on the 

output lines all SELV wiring should be segregated from the 
LV mains wiring and be wired using cable with insulation 
suitable for the application. 

To minimise the effects of EMC interference all data wiring 
circuits should be wired with a twisted pair of conductors with 
a cross sectional area suitable for the loading conditions. 

 

In areas where cabling may come into contact with high 
frequency interference, such as portable radio transceivers 
etc. the output wiring cable should be of a twisted pair 
construction within an overall screen. The screen should be 
terminated to one of the dedicated earth studs available in 
the panel (refer to panel manual for positions). 

NB:  Minimum  /  Maximum  cable  size  for  all  connections  is 
limited to 0.35mm² / 2.5mm² (22-14AWG). 

Summary of Contents for Mxp-007

Page 1: ...ndividually assigned to an output group to provide full support for the MxPro 4 system s DynamiX zoning facilities In addition each output has a number of programmable operational parameters including...

Page 2: ...r Mx 4400 control panel Up to two 2 Way or 8 Way Relay Output Cards can be fitted to an Mx 4800 control panel Compatibility The Mxp 007 is fully compatible with the Mx 4100 Mx 4200 Mx 4400 and Mx 4800...

Page 3: ...4 1 2 INSTALLING THE MXP 007 IN THE MX 4200 MX 4400 MX 4800 4 1 2 1 Mounting the Card 4 1 2 2 Internal Wiring 4 1 3 INSTALLING THE MXP 008 IN THE MX 4200 MX 4400 MX 4800 5 1 3 1 Mounting the Card 5 1...

Page 4: ...hed header PL2 to the 4 way latched header on the base card 1 2 Installing the Mxp 007 in the Mx 4200 Mx 4400 Mx 4800 1 2 1 Mounting the Card Base Card M3 Fixing Screws Mxp 007 The card mounts on 4 pi...

Page 5: ...uts are required on the Mx 4200 or Mx 4400 then use the deeper back box Mxm 020 or use the Termination Enclosures Mxm 028 or Mxm 029 as appropriate RELAY 1 RELAY 2 RELAY 3 RELAY 4 RELAY 5 RELAY 6 RELA...

Page 6: ...Mxp 008 By default the relays are all in the same Output Group 199 but this can be changed as required In the example below the relays have been assigned to groups 180 to 187 These output groups can b...

Page 7: ...ill be normally energised in its quiescent state and de energised when its Output Group setting is activated 2 3 May Walk Test If this parameter is ticked the relays assigned with this parameter will...

Page 8: ...www advancedco com 8 This page is intentionally left blank...

Page 9: ...www advancedco com USER NOTES...

Page 10: ...dco com Advanced Electronics Ltd Moorland Way Cramlington Northumberland NE23 1WE UK Tel 44 0 1670 707 111 Fax 44 0 1670 707 222 Email sales advancedco com Web www advancedco com Doc Number 680 028 Re...

Reviews: