Advanced ALS-ELUM-RGB-CNTRL-1 Installation Instructions Manual Download Page 5

5

A

dvAnced

 L

ighting

 S

yStemS

LLc

  

  519 L

incoLn

 R

oAd

  

  S

Auk

 c

entRe

, m

inneSotA

 56378  

  

t

 320 352 0088  

  

f

 320 352 0089  

  

AdvAncedLighting

.

com

  

  

nASdAq

nexS

5.0 DMX Operation

The interface uses 5 DMX channels to control the outputs. The starting address is set on the 
DIP switches or via RDM protocol. The first channel controls the red output, the second chan-
nel controls the green output, and the third channel controls the blue output. This is the normal 
method for DMX control. Channels 4 and 5 are used to access the special effects system. This 
allows the user to set a single channel to a level to trigger a fade, strobe, or to recall a specific 
preset color. During normal operation, channels 4 and 5 must be set to 0%. If either of these 
channels is above 0%, the levels set by channels 1 - 3 will be ignored. Channel 4 gives access 
to effects 4 - 25. Channel 5 gives access to effects 30 - 82. The mapping of specific DMX val-
ues to effect numbers is shown in a chart at the end of this document. Upon loss of the DMX 
input signal, the green LED will turn off and the outputs will hold the last levels received.

6.0 RDM Operation

The interface uses ESTA’s RDM protocol to remotely set the start address. In order to enable the 
RDM protocol, all 10 DIP switches must be in the OFF (down) position. When this is done, the 
yellow RDM ACTIVE LED will turn on. This indicates that the DMX address is set by RDM and can 
not be determined by examining the DIP switches. Using a Doug Fleenor Design RAD or similar 
device, the interface can be identified, its current DMX address can be found, and its DMX ad-
dress can be changed.

To use a RAD, do the following:

Connect a RAD to the interface (all 10 DIP switches must be OFF).

• 

Turn on the RAD.

• 

Push the NEXT button on the RAD. This causes the RAD to attempt to discover an RDM de-

• 

vice. The interface will identify itself by flashing the yellow RDM indicator and by flashing the 
red outputs at the same time. The RAD will display the current DMX address programmed 
into the interface. Note that the identify mode times out in about 30 seconds. Any changes 
to the address should be made within this time.
Set a new DMX address using the buttons below each digit on the RAD. When the desired 

• 

address is displayed, push the NEXT button on the RAD. The new address will be saved to 
the interface and the system will go back to normal operation. If more than one controller is 
on the line, pushing the NEXT button will cause the RAD to discover another device. Note 
that the discovery process will find devices based on their serial number; not by the order in 
which they are wired.

The RAD is normally used to set the DMX address for the interface. It can also access
the special effects if desired. This is done by setting the address to values in the 600
series of addresses. For example, setting the address to 601 will access effect 1 and
setting the address to 630 will access effect 30.

Summary of Contents for ALS-ELUM-RGB-CNTRL-1

Page 1: ...ALS ELUM RGB CNTRL 1 Model Number Installation INSTRUCTIONS eLum RGB Controller...

Page 2: ...eneral Information 2 0 Connections 3 0 Switches 4 0 Indicators 5 0 DMX Operation 6 0 RDM Operation 7 0 Manufacturers Note 8 0 Stand Alone Settings 9 0 Effects Chart 2 2 3 4 5 5 6 6 7 Page Table of Con...

Page 3: ...feet of eLum LED strips power cable and jumper cables The maximum amount of eLum Cove RGB that can be powered by each output junction is 10 3 feet 8 16 RGB Strips Below a typical eLum RGB system cont...

Page 4: ...o control the DMX termination on the interface When in the OFF position the DMX line is not terminated The signal is also routed to the DMX thru connections J4 and TB2 When the switch is in the ON pos...

Page 5: ...that the DMX address is set by RDM and can not be determined by examining the DIP switches Using a Doug Fleenor Design RAD or similar device the interface can be identified its current DMX address ca...

Page 6: ...1 0 0 0 Static light yellow 15 1 1 1 1 0 0 0 Static warm piink 16 0 0 0 0 1 0 0 Static light green 17 1 0 0 0 1 0 0 Static light salmon 18 0 1 0 0 1 0 0 Static light amber 19 1 1 0 0 1 0 0 Static ligh...

Page 7: ...green 20 sec 4 198 208 621 22 fade red blue green 15 sec 4 209 219 622 23 fade red blue green 10 sec 4 220 230 623 24 fade red blue green 5 sec 4 231 241 624 25 fade red blue green 1 sec 4 242 252 62...

Page 8: ...with any other manufacturer will void the entire warranty WARRANTY SERVICE CLAIMS Nexxus Lighting must issue a Return Material Authorization RMA number for all requests for warranty review To expedit...