4
Front Panel Basic Operation
(continued)
3. Password Authentication – if the menu is locked, press “OK” or use the shortcut
function button to enter password authentication. The display will show the following:
• The password is entered using the “F” keys based on the value entered in programming.
The password will be six digits in length. After the password has been entered the “OK”
key is pressed, and the display will show “P1”.
• Press “C” before “OK” will remove the value just entered.
• In any menu setting, Press “C” and the device will activate the password lock state and
go idle.
• If there are no buttons pressed for a minimum of 30 seconds, the repeater will enter the
password lock and idle state.
4. Channel Switching – the channels may be switched using the front panel arrow keys
after the password is entered if enabled. The display will show in the display between 01 to
99 depending on programming. After the arrow keys are used to select the channel, “OK”
is pressed to confirm the channel. “C” is pressed to return to the idle state and display the
current channel.
5. Volume Adjustment – the front speaker volume level is adjusted using the F3 / F4 keys.
The display will show values between U1 to U8 with U1 being the lowest and U8 being the
highest. “OK” is pressed to confirm the selected level. “C” is pressed to activate the level
and return to idle state.
6. Monitor Switch – when the key functions are in the idle state, press “OK” to enter the
monitor switch menu. The display will show “P1.” Press the right arrow key to enter the
menu, and “OK” to enter the monitor switch set-up.
•
The arrow keys allow the “ON” or “OF” (off) to be selected.
•
Press “OK” to confirm the selected setting. The setting will be saved and active. Pressing
“C” cancels the operation.
• Pressing “C” again navigates back to the P1 menu.
7. Transmit Power - when the key functions are in the idle state, press “OK” to enter the key
menu. Use the arrow key to navigate to the “P2” setting. Press “OK” to enter the transmit
power set-up.
• Press the arrow keys to increase or decrease the transmit power level. The display will
show the current power level and display the new power level setting from L1 to L9. L1 is
equal to 5-Watts and L9 is equal to 45-Watts.
•
Press “OK” to confirm and save the new power setting.
• Press “C” to cancel the operation.
8. Password Change – the password may be changed from the key function menu, the “P3”
setting. The arrow keys are used to navigate within the key function menu. You will need to
verify the old password before entering a new password.
• Press “OK” while “P3” is displayed. The display will change to two red dashes (
- -
)
• Authenticate the old password per item #3 in this section.
• After the password authentication tone, the new password may be entered.
• Using any combination of the F1 through F4 keys, set a new six-digit password and
press “OK” to confirm and save.
• Repeat the process and when the two entries are identical, the repeater will emit a tone
indicating that the entry process was correct. The display will revert to “P3” indicating the
new password is in effect. If a warning tone is heard, attempt to re-enter the password.
• Press “C” to cancel the operation and press “C” again to return to the idle state.