for the drain saddle clamp. Place ¼” drill bit inside template hole, and drill a hole into the 
drainpipe. DO NOT drill the hole clean through both sides of the drainpipe. This will result in 
a leak, and require a replacement piece of drainpipe. Drill through one side only. Mount the 
drain saddle clamp on top of the template with the holes aligned. Fit drain saddle clamp 
back-plate and screws. Alternate tightening screws on each side of the drain saddle clamp 
to ensure an even, snug fit. See Fig. 10. Screw plastic female fitting onto the drain saddle 
male fitting until it is snug, and wrap excess tubing around the drainpipe.  

5. Install water out line to RO sink spigot – 

Screw Speedfit® spigot adapter onto the 

bottom of the RO sink spigot located under the sink until it is snug. See Fig. 15.  Over 
tightening may cause damage. Insert tubing labeled “to RO spigot” into Speedfit® spigot 
adapter. Push tubing all the way in, then pull back gently to check fit. Most push-pull 
fittings take about a ¼” of tubing inserted into them. 

6. Install reserve tank and connect reserve line – 

Apply Teflon tape to the male fitting 

on top of the reserve tank. Screw on the reserve tank shut off valve until it is snug. (Fig. 
11) Over tightening may cause damage. Insert line marked “to reserve tank” from the Tap 
Master™ RO into the reserve tank shut off valve. Push tubing all the way in, then pull back 
gently, to check fit. Most push-pull fittings take about a ½” of tubing inserted into them. 
Make sure reserve tank shut off valve is in the OFF position, where the blue handle will be 
perpendicular to the body. Shown in the ON position in Fig. 11. 
 

7. Pressurize the Tap Master™ RO - 

For Tap Master UV & ULTRA first connect power 

adapter to UV filter so the filter glows blue at the bottom. Power supply should make noise 
when connected to wall outlet and not connected to UV filter, or if connected and the UV 
filter does not function. 
Double check to make sure all valves are in the OFF position, except for the main angle-
stop valve or piercing valve, which should be ON. Make sure unit is dry. Water should flow 
normally from your sink’s cold and hot faucets. Turn the easy adapter ball valve, or the 
shut off valve from the piercing valve to the ON position. You should hear water rushing 
through the system. Check for leaks at all fittings. Allow 5-15 minutes for system pressure 
to build. Turn valve on RO sink spigot to ON position by depressing and holding the lever 
down, or by flipping the lever up, where it should stay open. A steady trickle of water 
should be present after between 1-20 minutes. Some blackening of the water may present 
due to loose carbon being flushed out. Close the lever on the RO sink spigot, and open the 
reserve tank valve. Allow reserve tank to fill for 3.5 hours, and then drain completely. 
Repeat. System must be flushed prior to use. Plug in refrigerator electric plug; turn ON 
refrigerator line shut off valve so that the blue handle is parallel with the white body. Make 
sure refrigerator icemaker and water center are turned ON. Check for leaks. Check for 
pressure at the refrigerator’s water center if applicable. Dispose of the first two batches of 
ice after installing the Tap Master™ RO.  Use caution when rolling refrigerator back into 
place. DO NOT crimp or crush water line, as a leak will likely develop.  

IMPORTANT – 

After reserve tank has filled (3.5 hours), Drain entire reserve tank completely, 
until the flow from the RO sink spigot falls to a thin light stream. Repeat. Reserve 

Customer Service Hotline 1-800-453-4206 

 

 

 

Page 9 

Tap Master Owners Manual 

tank is full when the hissing noise stops. Discoloration of water may be present. 
System must be flushed twice prior to use. Allow another 3 hours for the reserve 
tank to refill. Enjoy!

 

 
 
 
 
 
 
 
 
 
 
 

Tap Master

®

 Filter Change Instructions 

Tools Required 
Scissors 
Towel 

 

1.  Clear away a workspace under the sink near the location of the Tap Master. 

2.  Turn off the water feeding the Tap Master, by closing the ball valve located on the water 

line, or by closing angle-stop feed water valve clockwise. To close the angle-stop, turn 
clockwise. If present, the angle-stop will be located on the wall under the kitchen sink in 
close proximity to the Tap Master. Either method will work. See Figures 4 & 6. For Tap 
Master UV & ULTRA disconnect power adapter. 

3.  Close the reserve tank valve located on top of the reserve tank. When closed the blue 

handle will perpendicular to the water line. See Figure 11. 

4.  Depressurize the system. Flip up the handle on the RO sink spigot so that it locks into 

place, and dispenses water until it no longer flows. See Figure 4. If you have successfully 
shut off the water this should occur within a few seconds. If water still continues to flow, 
repeat steps 2 & 3. The system is now depressurized; continue to leave to RO sink spigot 
handle in the open position.  

5.  Slowly and gently pull the Tap Master off of its mounting clips from the bottom up. Lay it 

on a towel. Pull off the first filter to be changed. IMPORTANT: Make note of flow direction 
arrows on the filter body and line then up with the replacement filter which you should 
position nearby. 

a.  To determine which replacement filter you should use, compare the labels on the 

filters and make sure the flow direction arrows face the same direction. Make note 

Summary of Contents for Water Dispenser

Page 1: ... Water Filters Where Technology and Water Combine Perfect Water Technologies Inc Copyright 2004 Customer Service Hotline 1 800 453 4206 Advanced Water Filters Tap Master Series Installation Service Manual Tap Master Tap Master IRON Tap Master UV Tap Master ULTRA Tap Master Artesian ...

Page 2: ...Customer Service Hotline 1 800 453 4206 Page 2 Tap Master Owners Manual Customer Service Hotline 1 800 453 4206 Page 15 Tap Master Owners Manual ...

Page 3: ...er1 5 micron granular activated carbon coconut shell carbon with IRON filtration 6 month or 1500 gallon service life 1 10 Carbon pre filter2 5 micron granular activated carbon coconut shell carbon 1 year or 3900 gallon service life 1 10 Carbon post filter 5 micron granular activated carbon coconut shell carbon 1 year or 3900 gallon service life 1 10 Artesian post filter4 5 micron granular activate...

Page 4: ...e sure refrigerator water center and or icemaker are turned ON and refrigerator is plugged in If water center works but icemaker does not then defrost the freezer as the line in may have frozen Hissing or flowing sounds from Tap Master RO are normal during the water purification process Sounds should last for approximately 1 hour per gallon of water used Sounds should stop once the reserve tank is...

Page 5: ...nate possible blockage points by disconnecting each system Customer Service Hotline 1 800 453 4206 Page 5 Tap Master Owners Manual while drilling and while under sink Using masonry bit and variable speed corded power drill slowly begin drilling through the porcelain Drill bit should be perpendicular to sink Failure to do so may cause the drill bit to slip and cause bodily injury and or property da...

Page 6: ...ten snugly Screw down the red T handle on top of the piercing valve until copper line is punctured then unscrew until water begins to flow at a fast rate Close attached shut off valve by turning blue handle perpendicular to the valve body Have a bowl or cup nearby to catch water Dry all parts check for leaks and snugness 2 Mount the Tap Master Identify location for installing mounting clips for th...

Page 7: ...te pump side by side with the tap master using supplied mounting clip and screws IMPORTANT permeate pump must be mounted with indicator arrow pointing up FOR ADDITIONAL INFORMATION ON USING QUICK CONNECT FITTINGS REFER TO PAGE 14 3 Install refrigerator kit optional Installation may vary according to make model age and equipment level of your refrigerator Make sure refrigerator icemaker and water c...

Page 8: ...steady trickle of water should be present after between 1 20 minutes Some blackening of the water may present due to loose carbon being flushed out Close the lever on the RO sink spigot and open the reserve tank valve Allow reserve tank to fill for 3 5 hours and then drain completely Repeat System must be flushed prior to use Plug in refrigerator electric plug turn ON refrigerator line shut off va...

Reviews: