OPERATOR SAFETY

A welder generator set 

must not be transported 

with any fuel in the fuel 

tank or carburetor in 

any vehicle. Fumes are a 

health hazard and there is 

always the danger of fire.  

NOTE:

   ALL NUTS AND BOLTS 

SHOULD BE CHECKED 

FOR TIGHTNESS ON A 

REGULAR BASIS.

M+H Power Systems Pty Ltd

10 Williamson Road, Ingleburn, NSW 2565

T: 1300 733 004

F: 1300 733 005
E: [email protected]

ABN 96 051 792 833

www.mpower.com.au

APOGwnw-500E   9-11

WELD ‘n’ WORK

WELDER GENERATOR

FINAL QUALITY INSPECTION

MODEL ............................ ALT ..................

SERIAL No ........................ DATE ..............

Engine 

p

Alternator / Welder 

p

Standard/Weather-proof Outlets 

p

Mounting Frame 

p

A/V Mounts 

p

Nameplate Stamped & Fitted 

p

Engine  to Alternator Assembly 

p

Engine/Alternator to Frame Assembly      

   

  

p

Paint Finish 

p

Test Procedure 

p

Fuel & Oil Drained 

p

Labels Correct & Secure 

p

All Bolts Tensioned 

p

Nyloc Nuts Correctly Fitted 

p

  

All Documents Included 

p

Electrical Connections 

p

Battery Charge & Fuse Protection 

p

Signed: ..............................................................

This certificate to be completed and signed by the person 
responsible for the final test and inspection procedure and 
packed with the completed generator set.

Summary of Contents for WELD 'n' WORK

Page 1: ...als or workmanship Excluded from this warranty are normal maintenance items consumable parts and equipment subjected to misuse abuse lack of maintenance or damage due to unauthorised servicing For warranty service the equipment must be returned freight pre paid to an authorised Advanced Power service agent Should you require warranty service or maintenance please contact MPower on 1300 733 004 A W...

Page 2: ...NKCASE WITH OIL as recommended in the engine owner s manual Check oil level daily DO NOT USE FRICTION MODIFIED OILS n USE ONLY FRESH QUALITY FUEL in your Advanced Power Welder Generator DO NOT use fuel that has been stored for several weeks n DO NOT ADJUST OPERATING SPEED This has been factory set Alteration will vary the output voltage and frequency which will cause damage to your appliances and ...

Page 3: ...Damage to your appliances and or welder generator may result from excessive voltage drop in the cable n NEVER CONNECT YOUR WELDER GENERATOR TO ANY WALL MOUNTED POWER OUTLET BY MEANS OF A CORD OR PLUG This will create a POTENTIALLY FATAL SITUATION ALL WIRING WORK associated with the connection of the generator to an existing ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A LICENSED ELECTRICAL CONTR...

Page 4: ... battery holder Secure in place by applying a gentle pressure with the battery holder clamp nuts n Making sure the start key is in the off position attach the red battery cable to the positive terminal of the battery Then attach the black cable to the negative terminal of the battery n The engine will recharge your battery during normal operating periods Should your battery need additional recharg...

Page 5: ...s before applying high loadings to your welder 11 If engine fails to start after several attempts fuel flooding may have occurred Open the choke try starting engine several times then repeat starting procedure TO STOP ENGINE Move start stop switch or key to off position DIESEL ENGINE STARTING OPERATION 1 Fill crankcase with oil as nominated in engine manual Place your generator on level ground Rem...

Page 6: ...thorised Service Centre is equipped with special service tools and trained mechanics to ensure expert service or repair on all engines n Major engine repairs should not be attempted without the proper tools and a thorough knowledge of engine repair procedures ADVANCED POWER GENERATING SETS OWNER S GUIDE 6 ENGINE ALTERNATOR SERVICE IF ENGINE SERVICE OR REPAIR IS NEEDED CONTACT AN AUTHORISED ENGINE ...

Page 7: ...cted to the rod holder must be plugged into one of the welding outlets as marked These relate to the maximum welding current available from that particular outlet and are designed to correspond with the control setting ranges on the Control Panel For welding the EARTH terminal must be connected to the earth cable which at all times must be clamped to the material been welded DO NOT ATTEMPT TO WELD...

Page 8: ...ELD n WORK WELDER GENERATOR FINAL QUALITY INSPECTION MODEL ALT SERIAL No DATE Engine p Alternator Welder p Standard Weather proof Outlets p Mounting Frame p A V Mounts p Nameplate Stamped Fitted p Engine to Alternator Assembly p Engine Alternator to Frame Assembly p Paint Finish p Test Procedure p Fuel Oil Drained p Labels Correct Secure p All Bolts Tensioned p Nyloc Nuts Correctly Fitted p All Do...

Reviews: