WELDER SERVICE

Your Advanced Power welder is designed to provide many years of trouble free operation. All servicing of 

the welder must be carried out by an Authorised Service Centre.

WELDING

ENSURE ALL A.C. AUXILIARY AND BATTERY CHARGING CABLES ARE DISCONNECTED COMPLETELY 

FROM THE TERMINALS ON THE WELDER-GENERATOR BEFORE WELDING.

The Selector Knob on the Control Panel allows adjustment of welder amperage to provide optimum current 

for each size electrode and type of job. If the job requires less amps for satisfactory welding, connect 

the cable to the low terminal and then adjust the Selector Knob to provide the correct current. If the job 

requires more amps, connect the cable to the high terminal and then adjust the Selector Knob to obtain the 

current required.

A thermal overload protection device is fitted which intervenes in case of overload by cutting off welder 

output. After approximately 1 minute, normal operation will be automatically restored.

Allow your generator/welder to warm up (approx 3 minutes) before you start welding and after any welding 

allow your generator welder to run (approximately 1 minute) to cool down before turning it off.

WELDING TERMINALS

The female terminals on the welder accept the loose supplied male terminals which should be fitted to the 

ends of the welder cables.

The primary welding cable (connected to the rod holder) must be plugged into one of the welding outlets 

as marked. These relate to the maximum welding current available from that particular outlet and are 

designed to correspond with the control setting ranges on the Control Panel.

For welding, the “EARTH” terminal must be connected to the earth cable which at all times must be 

clamped to the material been welded.

DO NOT ATTEMPT TO WELD CONTINUOUSLY. THE THERMAL OVERLOAD PROTECTION DEVICE WILL 

INTERVENE. IF THIS OCCURS REGULARLY IT MAY CAUSE DAMAGE TO THE UNIT.

1 PHASE A.C. GENERATOR POWER

ENSURE THE WELDING CABLES ARE DISCONNECTED COMPLETELY FROM THE TERMINALS ON THE 

WELDER/GENERATOR BEFORE USING A.C. POWER.

Set the Selector Knob to the “GEN” or (Generator) position and then plug the appliance cable into the 

normal A.C. socket provided.

Refer to the settings shown on the Control Panel.

DO NOT OPERATE 2 OPTIONS AT ONE TIME.

DO NOT REMOVE ANY BATTERY CONNECTIONS WHILE ENGINE IS RUNNING.

BATTERY CHARGING (If Fitted)

Your welder generator is fitted with a 12 VDC trickle charger. To charge your battery, ensure your welder 

generator is turned off and connect the battery using appropriate battery leads. Make sure the red lead 

connects to the positive (+) terminal of the battery and black to the negative (-). Start your welder generator 

and your battery is now been charged. Not suitable for batteries above 100 amp hour. NOTE, output is not 

regulated and connection of small batteries for long periods of time may cause damage to the battery.

ADVANCED POWER GENERATING SETS

OWNER’S GUIDE

7

Summary of Contents for WELD 'n' WORK

Page 1: ...als or workmanship Excluded from this warranty are normal maintenance items consumable parts and equipment subjected to misuse abuse lack of maintenance or damage due to unauthorised servicing For warranty service the equipment must be returned freight pre paid to an authorised Advanced Power service agent Should you require warranty service or maintenance please contact MPower on 1300 733 004 A W...

Page 2: ...NKCASE WITH OIL as recommended in the engine owner s manual Check oil level daily DO NOT USE FRICTION MODIFIED OILS n USE ONLY FRESH QUALITY FUEL in your Advanced Power Welder Generator DO NOT use fuel that has been stored for several weeks n DO NOT ADJUST OPERATING SPEED This has been factory set Alteration will vary the output voltage and frequency which will cause damage to your appliances and ...

Page 3: ...Damage to your appliances and or welder generator may result from excessive voltage drop in the cable n NEVER CONNECT YOUR WELDER GENERATOR TO ANY WALL MOUNTED POWER OUTLET BY MEANS OF A CORD OR PLUG This will create a POTENTIALLY FATAL SITUATION ALL WIRING WORK associated with the connection of the generator to an existing ELECTRICAL INSTALLATION MUST BE CARRIED OUT BY A LICENSED ELECTRICAL CONTR...

Page 4: ... battery holder Secure in place by applying a gentle pressure with the battery holder clamp nuts n Making sure the start key is in the off position attach the red battery cable to the positive terminal of the battery Then attach the black cable to the negative terminal of the battery n The engine will recharge your battery during normal operating periods Should your battery need additional recharg...

Page 5: ...s before applying high loadings to your welder 11 If engine fails to start after several attempts fuel flooding may have occurred Open the choke try starting engine several times then repeat starting procedure TO STOP ENGINE Move start stop switch or key to off position DIESEL ENGINE STARTING OPERATION 1 Fill crankcase with oil as nominated in engine manual Place your generator on level ground Rem...

Page 6: ...thorised Service Centre is equipped with special service tools and trained mechanics to ensure expert service or repair on all engines n Major engine repairs should not be attempted without the proper tools and a thorough knowledge of engine repair procedures ADVANCED POWER GENERATING SETS OWNER S GUIDE 6 ENGINE ALTERNATOR SERVICE IF ENGINE SERVICE OR REPAIR IS NEEDED CONTACT AN AUTHORISED ENGINE ...

Page 7: ...cted to the rod holder must be plugged into one of the welding outlets as marked These relate to the maximum welding current available from that particular outlet and are designed to correspond with the control setting ranges on the Control Panel For welding the EARTH terminal must be connected to the earth cable which at all times must be clamped to the material been welded DO NOT ATTEMPT TO WELD...

Page 8: ...ELD n WORK WELDER GENERATOR FINAL QUALITY INSPECTION MODEL ALT SERIAL No DATE Engine p Alternator Welder p Standard Weather proof Outlets p Mounting Frame p A V Mounts p Nameplate Stamped Fitted p Engine to Alternator Assembly p Engine Alternator to Frame Assembly p Paint Finish p Test Procedure p Fuel Oil Drained p Labels Correct Secure p All Bolts Tensioned p Nyloc Nuts Correctly Fitted p All Do...

Reviews: