Table 8. Default flexible links
Flexible Link
Default Link Setting
Flexible read-link 01 r
Power Controller #1: Total power - read
Flexible read-link 02 r
Power Controller #1: L1 Urms - read
Flexible read-link 03 r
Power Controller #1: L1 Irms - read
Flexible read-link 04 r
Power Controller #1: L1 Power - read
Flexible read-link 05 r
Power Controller #1: L1 Resistance - read
Flexible read-link 06 r
Power Controller #1: L1 Umains - read
Flexible read-link 07 r
Power Controller #1: L1 Temperature - read
Flexible read-link 08 r
Power Controller #1: L2 Urms - read
Flexible read-link 09 r
Power Controller #1: L2 Irms - read
Flexible read-link 10 r
Power Controller #1: L2 Power - read
Flexible read-link 11 r
Power Controller #1: L2 Resistance - read
Flexible read-link 12 r
Power Controller #1: L2 Umains - read
Flexible read-link 13 r
Power Controller #1: L2 Temperature - read
Flexible read-link 14 r
Power Controller #1: L3 Urms - read
Flexible read-link 15 r
Power Controller #1: L3 Irms - read
Flexible read-link 16 r
Power Controller #1: L3 Power - read
Flexible read-link 17 r
Power Controller #1: L3 Resistance - read
Flexible read-link 18 r
Power Controller #1: L3 Umains - read
Flexible read-link 19 r
Power Controller #1: L3 Temperature - read
Flexible read-link 20 r
Not applicable
INSTALLING OPTIONAL MODULES
DANGER:
RISK OF DEATH OR BODILY INJURY. Disconnect and lockout/tagout all sources of input
power before working on this unit or anything connected to it.
DANGER:
RISQUE DE MORT OU DE BLESSURES CORPORELLES. Débrancher et verrouiller/
étiqueter toutes les sources de puissance d’entrée avant de travailler sur cette unité ou sur
tout élément qui y est raccordé.
The optional modules may be shipped separately.
1. Verify that the unit is disconnected from all power sources.
Advanced Energy
®
Thyro-PX
™
Anybus
®
Modbus TCP
57010166-00A
Thyro-PX
™
Anybus
®
Modbus TCP
8