SERVICE MANUAL
ENGLISH
Adinity™ 17 ST / 20 ST / 20 D / X 20 D / X 20 C / X 24 D
9096982000(2)2009-06
21
SOLUTION/CLEAN WATER SUPPLY SYSTEM
SOLUTION FILTER CLEANING (For Adinity™ 20 D)
Drive the machine on a level loor.
1.
Turn the ignition key (80) to “0”.
2.
Close the solution tap (A) under the machine left lower side. The tap (A) is closed when it is on the position (B) and it is open
3.
when it is on the position (C).
Remove the transparent cover (D), then remove the ilter strainer (E). Clean and install them on the support (F).
4.
NOTE
The ilter strainer (E) must be correctly positioned on the housing (G) of the support (F).
Open the tap (A).
5.
E
G
B
A
D
C
F
E
S301521A
SOLENOID VALVE DISASSEMBLY/ASSEMBLY (For Adinity™ 17 ST, 20 ST)
Disassembly
Remove the brush.
1.
Lower the deck by pressing the pedal (11).
2.
Remove the screw (A), disconnect the connector (B) and recover the gasket.
3.
Disconnect the union (C) from the solenoid valve (D) and recover the gasket.
4.
Remove the screws (E).
5.
Slightly lift the solenoid valve (D), disconnect the union (F) and recover the gasket.
6.
Recover the solenoid valve (D).
7.
Assembly
Assemble the components in the reverse order of disassembly.
8.
F
E
A
B
D
C
S301522A