Summary of Contents for MIN600SI

Page 1: ...Cod 0103086447 00 03 ...

Page 2: ...mply with all EU UK statutory requirements and complies with all applicable legislation and the following European Directives The Low Voltage Directive 2014 35 EU Electromagnetic Compatibility Directive 2014 30 EU The product has been marked with the UKCA and CE symbols ...

Page 3: ...This appliance is marked according to the European directive 2004 104 EC on Waste Electrical and Electronic equipment WEEE ...

Page 4: ...of less than 36 m3 Steam cleaners must not be used when cleaning this appliance The performance of your extractor will vary depending on a number of factors These include type of extraction length of ducting room volume ventilation available and cleanliness of the filters ...

Page 5: ......

Page 6: ...and drying to a shine with a clean cloth for example a clean microfibre cloth Cleaning the rectangular grease filter The grease filter captures grease particles in the air so is therefore subject to clogging depending on the frequency of use of the appliance In order to prevent fire hazard it is recommended to clean the grease filter at a maximum of 2 month intervals by carrying out these instruct...

Page 7: ...de in the extractor and then refasten the fixing clips on the lower side Aluminium grease filters 1 Remove the filters from the cooker hood and wash in a solution of warm water and neutral liquid detergent leaving to soak 2 Rinse thoroughly with warm water and leave to dry 3 The filters may alternatively be washed in the dishwasher The aluminium panels may alter in colour after several washes in a...

Page 8: ...8 Replaceable LED only light Fig 1 I Fig 1 II Fig 1 III source by an end user LED LED E14 LED 4Wx1 DR 4 H E14 37 ...

Page 9: ... recommended for your extractor Do not fit bulbs of a higher power rating Bulbs of a lower power rating may be adequate for use generally last longer and use less energy Spare bulbs are available from CDA Customer Care ...

Page 10: ...tance between the hob and extractor must be greater than 700mm then that is the distance that should be observed this is a legal requirement and may lead to your hob being disconnected from the gas supply and the installation being reported to RIDDOR The height should be measured from the top of the burners NOTE IN THE ABSENCE OF ANY INSTRUCTIONS SUPPLIED WITH THE GAS HOB THE MINIMUM DISTANCE BETW...

Page 11: ...extractor on 3 Mount the brackets and securely tighten 4 Hang the hood on the brackets and adjust the brackets and height to suit The adjustment mechanism is shown in Fig 4 5 Once the hood is levelled and square against the wall adjust the bottom panel as required Fig 5 6 Secure the extractor to the adjacent units through the holes in the side of the product to ensure that it cannot be accidentall...

Page 12: ...BLE POLE SWITCHED FUSED SPUR OUTLET AND PROTECTED BY A 3A FUSE We recommend that the appliance is connected by a qualified electrician who is a member of the N I C E I C and who will comply with the I E T and local regulations The wires in the mains lead of this appliance are coloured in accordance with the following code BLUE NEUTRAL BROWN LIVE ...

Page 13: ... installing this product we recommend you seek the help of another individual IMPORTANT THIS APPLIANCE IS A CLASS II APPLIANCE DOUBLE INSULATED AND IS NOT INTENDED TO BE EARTHED DO NOT FIT AN EARTH LEAD TO THIS EXTRACTOR Do not mount the isolation switch behind the chimney section It is a requirement that you must be able to isolate the extractor from the mains electrical supply after installation...

Page 14: ...ng 1 Check that the mains supply has not been switched off 2 Check that the fuse in the spur has not blown Contact CDA Customer Care A Customer Care Department The CDA Group Ltd Harby Road Langar Nottinghamshire NG13 9HY T 01949 862 012 F 01949 862 003 E customer care cda eu W www cda eu DOUBLE POLE SWITCHED FUSED SPUR OUTLET USE A 3 AMP FUSE ...

Page 15: ...ressure at Best Efficiency Point PBEP 120 0 Pa Q w o l f r i a m u m i x a M MAX 193 2 m3 h Measured electric power at Best Efficiency Point WBEP 38 2 W Nominal lighting power WL 4 W Average illumination of the lighting system on the cooking surface EMiddle 55 0 Lux Measured power consumption in standby PS W Measured power consumption off mode PO 0 0 W Sound power level LWA 62 0 dBA Grease Filter ...

Page 16: ...Serviced by The CDA Group Ltd Harby Road Langar Nottinghamshire NG13 9HY Tel 01949 862012 Fax 01949 862003 Email customer care cda eu For our Customer Care Department or for Service please contact us on ...