ADURO Asgard 9-1 User Manual Download Page 7

35 

 

In order to reduce the risk of ash falling from the stove when the door is opened to add more fuel, it is a good 
idea to open the primary damper for approx. 1 minute before the door is opened. This increases the draft 
through the stove and reduces the risk that ash will drop on the floor.  

 

 

 

 

 

 

3.2 Aduro-tronic  

The patent-applied control Aduro-tronic is a manually operated mechanical start-up 
device, which works without the use of electricity and automatically regulates the 
combustion. All you have to do is put dry wood in the stove and activate the control 
system. Aduro-tronic does the rest, leaving you to enjoy the flames, the benefits of 
efficient combustion, and a reduced firewood usage up to 40 %. For further 
information, go to 

www.adurofire.com

.   

 

3.2.1 How to operate Aduro-tronic 

When lighting 

When lighting a fire in the stove for the first time, the maximum 
amount of primary air will be needed to light the fire. For that reason, 
the primary damper can be kept “forcibly open”. This is done by 
pulling the primary damper forward as far as possible and then fixing 
it with the Aduro Key (see illustration). When the stove is warm and a 
layer of embers has been created on the bottom of the combustion 
chamber, the Aduro-tronic can be set to the automatic position, i.e. 
the Aduro Key can be removed. Alternatively, you can leave the door 
ajar the first minutes during lighting the fire (without the key).

 

 

When stoking 

Each time fresh wood is put in the stove, a precise amount of primary 
air will be allowed in for the firs

t few minutes. What’s more important 

is that the primary air is not allowed in for too long. This is to ensure 
optimum combustion. The Aduro-tronic control will ensure intake of primary air at the right tempo. The 
automatic is activated by pulling the primary damper out each time fresh wood is put in the stove. The 
automatic closes then the primary air gradually. 

 

Regulation of the Aduro-tronic control 

The control is pre-set to close the primary air intake within 6 minutes. This setting has been used during 
testing at the Danish Technological Institute using a standard chimney and ‘standard’ sized logs (approx. 30 
cm long, 10x10 cm thick) with maximum moisture content of 18%. In practice, such circumstances can differ, 
which is why the Aduro-tronic control can be adjusted to your circumstances. If you want a slower intake of 

If you overload the wood burning stove and burn more than approx. 3.1 kg 
wood/hour, there is a risk that the lacquered surface of the stove will become 
discoloured and eventually fall off. The stove can be resurfaced, but this is not 
covered by the manufacturer’s guarantee. In the same way, any other damage to 
the stove caused by overloading will not be covered by the guarantee. 

Summary of Contents for Asgard 9-1

Page 1: ...rofire de adurofire com adurofire se aduro fr aduro es aduro it Brugsvejledning Bedienungsanleitung User Manual Mode d emploi Eldningsinstruktion Manual de usuario Manuale d uso e manutenzione DK NO 2...

Page 2: ...com warranty The deadline for registering is five months from the date of purchase Production number The wood stove has a production number on the rating plate on the back of the stove We recommend t...

Page 3: ...m Distance from floor to centre of rear outlet 84 cm Distance from centre of exhaust branch to rear edge of stove 19 3 cm Weight 100 kg Material Sheet iron Fuel Wood and wood briquettes Max wood lengt...

Page 4: ...n force are complied with 2 1 Position of the stove distance requirements The wood burning stove must be installed in a suitable and physically possible position You need to be sure that the position...

Page 5: ...e ashpan A flue pipe with an internal diameter of 150 mm should be used for Aduro stoves Please ensure that all local rules and regulations are complied with including CE marking of the exhaust connec...

Page 6: ...iary air while firing the stove 3 1 1 Secondary damper The secondary damper behind the door should always be open while the wood burning stove is in use This damper allows you to adjust the wood burni...

Page 7: ...tion i e the Aduro Key can be removed Alternatively you can leave the door ajar the first minutes during lighting the fire without the key When stoking Each time fresh wood is put in the stove a preci...

Page 8: ...in the combustion chamber is another factor that affects combustion The optimum combustion is achieved by placing two logs in the stove If you want an enhanced effect you can add more logs The ideal...

Page 9: ...ted 2 Place a log of wood crosswise in the combustion chamber and put 2 firelighters close to the log Light the firelighters and quickly put a new log close to the firelighters and several small logs...

Page 10: ...ll be between 18 25 Pa when conditions are optimum There are many factors that affect the chimney draft including the outside temperature wind strength and surrounding buildings There are no requireme...

Page 11: ...stion chamber and some of it might leak out of the stove Therefore if you have a cold chimney that has not been used for a while we recommend that you use some wood sticks to heat the chimney and elim...

Page 12: ...ue pipe can be removed from the stove and cleaned Cleaning of the inside of the stove and the flue pipe should be undertaken at least once a year or more frequently if necessary depending on how often...

Page 13: ...installation and use of the stove The right of complaint also does not cover loose and wearing parts glass gaskets firebricks handles slides painted surfaces cast iron grate etc as they are subject to...

Reviews: