In practice, the chimney draft will differ 

– especially in cold condition. Therefore, the best indication of the 

chimney draft is to measure the draft when it is hot. If the chimney sweep judges the draft to be sufficient, but 
you still have problems lighting a fire, try extending the fire lighting phase by using more thin pieces of 
kindling and 1-2 firelighters, so that the chimney gets thoroughly warm. The chimney will not draw at 
optimum effect until it is warm. When a layer of embers has been formed, add 2-3 dry logs. 

If it is impossible to establish a sufficiently natural chimney draft, the chimney can be fitted with a smoke 
exhauster, e.g. Aduro DraftOptimizer.  

 

4.2 Chimney and Smoke  

If you experience smoke coming out of the stove or the start section of the smoke pipe, it could be due to 
certain weather conditions. On stormy or cold winter days or if the chimney has not been used in a while, a 
cold plug can be created in the chimney, meaning the natural draft will be at its minimum. 

If the chimney is cold and cold plugs are created, you may experience smoke leaks during the ignition and 
startup phase. In this situation there can be more smoke than usually in the combustion chamber and some 
of it might leak out of the stove. Therefore, if you have a cold chimney that has not been used for a while, we 
recommend that you use some wood sticks to heat the chimney and eliminate the cold plug. 

 

 

5. Maintenance and cleaning of the stove 

 

Pakninger 

Med tiden bliver pakningerne slidte og bør derfor efterses. Er de utætte, bør de skiftes.  

 

 

Combustion chamber 

The fireproof tiles in the combustion chamber eventually wear out and should be replaced when the cracks 
are more than 0.5 cm. The durability of the tiles depends on how often and how intensively the stove is used.

 

You can change the tiles yourself.

 

They are available as a ready-to-use set. For further information, go to 

www.aduroshop.com

. 

 

Glass 

Wet wood, unsatisfactory chimney draft, and wrong use of the stove can leave soot stains on the glass pane. 
They can easily be removed using a damp cloth that you dip in cold ash and rub on the sooty glass. Special 
cleaning agents are also available to remove soot from glass, e.g. the Aduro Easy Clean pad. The pad 
neither scratch nor damage the glass and is for multiple usage. Water or other cleaning agents are not 
necessary.  

It is common maintenance to tighten the glass fittings shortly after the stove has been installed as well as to 
check if the gaskets are properly placed.  

 

 

All maintenance and cleaning of the stove should be carried out when it is 
cold. 

Summary of Contents for Asgard 9-1

Page 1: ...rofire de adurofire com adurofire se aduro fr aduro es aduro it Brugsvejledning Bedienungsanleitung User Manual Mode d emploi Eldningsinstruktion Manual de usuario Manuale d uso e manutenzione DK NO 2...

Page 2: ...com warranty The deadline for registering is five months from the date of purchase Production number The wood stove has a production number on the rating plate on the back of the stove We recommend t...

Page 3: ...m Distance from floor to centre of rear outlet 84 cm Distance from centre of exhaust branch to rear edge of stove 19 3 cm Weight 100 kg Material Sheet iron Fuel Wood and wood briquettes Max wood lengt...

Page 4: ...n force are complied with 2 1 Position of the stove distance requirements The wood burning stove must be installed in a suitable and physically possible position You need to be sure that the position...

Page 5: ...e ashpan A flue pipe with an internal diameter of 150 mm should be used for Aduro stoves Please ensure that all local rules and regulations are complied with including CE marking of the exhaust connec...

Page 6: ...iary air while firing the stove 3 1 1 Secondary damper The secondary damper behind the door should always be open while the wood burning stove is in use This damper allows you to adjust the wood burni...

Page 7: ...tion i e the Aduro Key can be removed Alternatively you can leave the door ajar the first minutes during lighting the fire without the key When stoking Each time fresh wood is put in the stove a preci...

Page 8: ...in the combustion chamber is another factor that affects combustion The optimum combustion is achieved by placing two logs in the stove If you want an enhanced effect you can add more logs The ideal...

Page 9: ...ted 2 Place a log of wood crosswise in the combustion chamber and put 2 firelighters close to the log Light the firelighters and quickly put a new log close to the firelighters and several small logs...

Page 10: ...ll be between 18 25 Pa when conditions are optimum There are many factors that affect the chimney draft including the outside temperature wind strength and surrounding buildings There are no requireme...

Page 11: ...stion chamber and some of it might leak out of the stove Therefore if you have a cold chimney that has not been used for a while we recommend that you use some wood sticks to heat the chimney and elim...

Page 12: ...ue pipe can be removed from the stove and cleaned Cleaning of the inside of the stove and the flue pipe should be undertaken at least once a year or more frequently if necessary depending on how often...

Page 13: ...installation and use of the stove The right of complaint also does not cover loose and wearing parts glass gaskets firebricks handles slides painted surfaces cast iron grate etc as they are subject to...

Reviews: