background image

31 

 

 

1. General 

 

1.1 Compliance 

Aduro 9 air complies with the EN13240 European standard as well as the NS3058 Norwegian standard and 
is thereby approved for installation and use in Europe. At the same time, the manufacturing process is 
subject to external quality control. Aduro 9 air also carries the Nordic Ecolabel, which guarantees that the 
wood burning stove complies with the most stringent environmental requirements and has been 
manufactured in an environmentally correct manner. DoP (Declaration of Performance) can be downloaded 
at 

www.adurofire.com/download

 

 

1.2 Technical data 

Aduro 9 air 

Data 

Nominal power  

6.0 kW 

Flue outlet, diameter 

Ø15 cm top/rear 

Measurements (HxBxD) 

95.8 x 50 x 44.7 cm 

Height exhaust branch above floor  

92.8 cm 

Distance from floor to centre of rear outlet 

84 cm 

Distance from centre of exhaust branch to rear edge of stove 

20.3 cm 

Weight 

103 kg 

Material 

Cast iron 

Fuel 

Wood and wood briquettes 

Max wood length 

39 cm 

Convection stove 

 

Primary, secondary, and tertiary air supply 

 

Air-wash system 

 

Ashpan 

 

Energy efficiency 

81.3 % 

Energy efficiency index 

108.9 

Energy efficiency class 

A+ 

Chimney draft 

12 Pa 

Maximum combustion amount per hour (wood) 

Approx. 3.1 kg 

Heat rating in buildings with 
- Optimum insulation 
- Average insulation 
- Inadequate insulation 

 
150 m

2

 

100 m

  60 m

 

1.3 Transportation 

 

When taking your wood burning stove home, please ensure that it travels in an upright position. If you wish 
to lay it flat, it is important that you remove all loose parts from the combustion chamber (cast iron grate and 
loose fireproof tiles) and remove the ashpan. Please use wood from the packaging for the first use. The 
plastic packaging should be discarded. 

 

Summary of Contents for 9 air

Page 1: ...durofire de adurofire com adurofire se aduro fr aduro es aduro it Brugsvejledning Bedienungsanleitung User Manual Mode d emploi Eldningsinstruktion Manual de usuario Manuale d uso e manutenzione DK NO 2 15 ES 89 81 IT 82 94 FR 56 68 UK 30 42 DE 16 29 SE 43 55 ...

Page 2: ...e com warranty The deadline for registering is five months from the date of purchase Production number The wood stove has a production number on the rating plate on the back of the stove We recommend that you note down this number in the box below before mounting the wood stove For the purposes of the guarantee and for other enquiries it is important that you are able to quote this number Enjoy HO...

Page 3: ...8 cm Distance from floor to centre of rear outlet 84 cm Distance from centre of exhaust branch to rear edge of stove 20 3 cm Weight 103 kg Material Cast iron Fuel Wood and wood briquettes Max wood length 39 cm Convection stove Primary secondary and tertiary air supply Air wash system Ashpan Energy efficiency 81 3 Energy efficiency index 108 9 Energy efficiency class A Chimney draft 12 Pa Maximum c...

Page 4: ...y if the wood burning stove is to be placed close to flammable materials Distance to flammable material see illustration Behind the stove Behind stove with insulated flue pipe To the sides Above the stove Distance to furniture 15 cm 10 cm 70 cm 75 cm 90 cm If the stove is positioned against a brick wall or other non flammable material there are no minimum distance requirements To facilitate cleani...

Page 5: ...ng in the chimney see the illustration below The stove can be connected to a chimney to which other heat sources are connected 2 4 Supply of combustion air All wood burning stoves need constant supply of air to ensure a clean and efficient combustion This is often a problem in modern energy efficient houses that are very tight Therefore the Aduro 9 air is equipped with external supply of combustio...

Page 6: ...tove see illustration below If you want to use the wood burning stove without connecting the supply of combustion air brake off the cover plate in the rear cover at the bottom of the back of the stove 2 5 Ways of installation Indirect through external wall Through floor and foundation Through wall Trough floor and crawl space ...

Page 7: ...he fire has gone out Please wait to empty the ashpan until you are sure that there are no embers in the ash The door should be kept closed while the wood burning stove is in use While lighting the fire the door can stand ajar for the first few minutes In the event of a chimney fire Close all the dampers on the wood burning stove and call the fire fighting service 3 1 Damper The stove is equipped w...

Page 8: ...Primary damper When you add a new log the primary damper should be opened until the fire is burning properly In order to utilize the fuel to the fullest extent the embers should have burnt for so long that it is necessary to open the primary damper for approx 2 minutes to get the new log to burn In order to reduce the risk of ash falling from the stove when the door is opened to add more fuel it i...

Page 9: ... to ensure optimum combustion The Aduro tronic control will ensure intake of primary air at the right tempo The automatic is activated by pulling the primary damper out each time fresh wood is put in the stove The automatic closes then the primary air gradually Regulation of the Aduro tronic control The control is pre set to close the primary air intake within 6 minutes This setting has been used ...

Page 10: ...he first few times the wood burning stove is used there may be some smoke and unpleasant odours from the wood burning stove which is fairly normal This is caused by the heat resistant paint hardening Make sure there is sufficient ventilation during this stage It is also important not to let the fire burn too fiercely the first 2 3 times so that the wood burning stove has time to expand slowly You ...

Page 11: ...nated wood chipboard paper and other waste is strictly forbidden Burning these materials will damage the environment the wood burning stove and your own health Fossil fuels must not be used 4 The chimney The optimum combustion is achieved at a constant chimney draft of 10 14 Pascal Pa measured in the flue pipe above the stove when having a smoke exhauster However with natural draft chimney without...

Page 12: ...hauster e g Aduro DraftOptimizer 4 2 Chimney and Smoke If you experience smoke coming out of the stove or the start section of the smoke pipe it could be due to certain weather conditions On stormy or cold winter days or if the chimney has not been used in a while a cold plug can be created in the chimney meaning the natural draft will be at its minimum If the chimney is cold and cold plugs are cr...

Page 13: ...t deflector can be removed To allow free access to the top of the stove and the flue pipe remove the exhaust deflector in steel The flue pipe can be removed from the stove and cleaned Cleaning of the inside of the stove and the flue pipe should be undertaken at least once a year or more frequently if necessary depending on how often the stove is used This work can also be carried out by the chimne...

Page 14: ... installation and use of the stove The right of complaint also does not cover loose and wearing parts glass gaskets firebricks handles slides painted surfaces cast iron grate etc as they are subject to wear during normal use These parts can be bought as spare parts in our webshop www aduroshop com In addition the right of complaint does not cover Damages resulting from incorrect installation and u...

Reviews: