ADURO 9 air User Manual Download Page 11

39 

 

3.  Keep the door approx. 1 cm ajar, until the glass is too hot to touch. Then close the door. When there 

are distinct, visible flames and the fire has taken hold, close the primary air intake/damper (see 
section 3.1.2). 

 

 

 

 

 

3.6 Recommended fuels 

Wood and wood briquettes. We recommend the use of split hardwood that has been stored outdoors under 
cover for at least 1 year. Wood that has been stored indoors has a tendency to become too dry and will burn 
too quickly. We recommend that you fell the wood during the winter when a lot of the moisture in the wood 
will have been drawn down into the roots. In order to achieve optimum combustion, the wood’s moisture 
level should not exceed 18 %, which roughly corresponds to storing the wood under cover outdoors for one 
year. The moisture level of the wood can be measured using a moisture meter or by applying dishwashing 
liquid to one end of the log and blowing air in the other end. If the wood is dry enough, soap bubbles will 
appear. The wood should be chopped into logs with a diameter of approx. 10 cm and a log length of max. 39 
cm. Firing with wet fuel will reduce the energy efficiency and increase the particle emission.  

Burning varnished wood, impregnated wood, chipboard, paper, and other waste is strictly forbidden. Burning 
these materials will damage the environment, the wood burning stove, and your own health. Fossil fuels 
must not be used. 
 
 

4. The chimney 

 

The optimum combustion is achieved at a constant chimney draft of 10-14 Pascal (Pa) measured in the flue 
pipe above the stove (when having a smoke exhauster). However, with natural draft (chimney without smoke 
exhauster) the draft in the chimney will be between 18-25 Pa when conditions are optimum. There are many 
factors that affect the chimney draft, including the outside temperature, wind strength, and surrounding 
buildings. There are no requirements with respect to specific chimney heights, but a chimney must be tall 
enough to provide a good draft. If the recommended chimney draft is not achieved, there may be problems 
with smoke out of the door by firing. 

 

Data for chimney calculation

 

Wood 

Flue temperature at [20°C] 

245 

Chimney draft at testing power [mbar]/[Pa] 

0.12/12 

Flue gas mass flow [g/s] 

5.7 

 

4.1 Inadequate draft in the chimney 

If you experience poor draft in the stove after the installation, please make sure that there is nothing in the 
chimney to restrict the smoke and that no nearby buildings or trees affect the winds around the chimney. 

The control handles will get warm when the wood burning stove is in use. 
Please use the glove provided when you operate the wood burning stove. 

Summary of Contents for 9 air

Page 1: ...durofire de adurofire com adurofire se aduro fr aduro es aduro it Brugsvejledning Bedienungsanleitung User Manual Mode d emploi Eldningsinstruktion Manual de usuario Manuale d uso e manutenzione DK NO 2 15 ES 89 81 IT 82 94 FR 56 68 UK 30 42 DE 16 29 SE 43 55 ...

Page 2: ...e com warranty The deadline for registering is five months from the date of purchase Production number The wood stove has a production number on the rating plate on the back of the stove We recommend that you note down this number in the box below before mounting the wood stove For the purposes of the guarantee and for other enquiries it is important that you are able to quote this number Enjoy HO...

Page 3: ...8 cm Distance from floor to centre of rear outlet 84 cm Distance from centre of exhaust branch to rear edge of stove 20 3 cm Weight 103 kg Material Cast iron Fuel Wood and wood briquettes Max wood length 39 cm Convection stove Primary secondary and tertiary air supply Air wash system Ashpan Energy efficiency 81 3 Energy efficiency index 108 9 Energy efficiency class A Chimney draft 12 Pa Maximum c...

Page 4: ...y if the wood burning stove is to be placed close to flammable materials Distance to flammable material see illustration Behind the stove Behind stove with insulated flue pipe To the sides Above the stove Distance to furniture 15 cm 10 cm 70 cm 75 cm 90 cm If the stove is positioned against a brick wall or other non flammable material there are no minimum distance requirements To facilitate cleani...

Page 5: ...ng in the chimney see the illustration below The stove can be connected to a chimney to which other heat sources are connected 2 4 Supply of combustion air All wood burning stoves need constant supply of air to ensure a clean and efficient combustion This is often a problem in modern energy efficient houses that are very tight Therefore the Aduro 9 air is equipped with external supply of combustio...

Page 6: ...tove see illustration below If you want to use the wood burning stove without connecting the supply of combustion air brake off the cover plate in the rear cover at the bottom of the back of the stove 2 5 Ways of installation Indirect through external wall Through floor and foundation Through wall Trough floor and crawl space ...

Page 7: ...he fire has gone out Please wait to empty the ashpan until you are sure that there are no embers in the ash The door should be kept closed while the wood burning stove is in use While lighting the fire the door can stand ajar for the first few minutes In the event of a chimney fire Close all the dampers on the wood burning stove and call the fire fighting service 3 1 Damper The stove is equipped w...

Page 8: ...Primary damper When you add a new log the primary damper should be opened until the fire is burning properly In order to utilize the fuel to the fullest extent the embers should have burnt for so long that it is necessary to open the primary damper for approx 2 minutes to get the new log to burn In order to reduce the risk of ash falling from the stove when the door is opened to add more fuel it i...

Page 9: ... to ensure optimum combustion The Aduro tronic control will ensure intake of primary air at the right tempo The automatic is activated by pulling the primary damper out each time fresh wood is put in the stove The automatic closes then the primary air gradually Regulation of the Aduro tronic control The control is pre set to close the primary air intake within 6 minutes This setting has been used ...

Page 10: ...he first few times the wood burning stove is used there may be some smoke and unpleasant odours from the wood burning stove which is fairly normal This is caused by the heat resistant paint hardening Make sure there is sufficient ventilation during this stage It is also important not to let the fire burn too fiercely the first 2 3 times so that the wood burning stove has time to expand slowly You ...

Page 11: ...nated wood chipboard paper and other waste is strictly forbidden Burning these materials will damage the environment the wood burning stove and your own health Fossil fuels must not be used 4 The chimney The optimum combustion is achieved at a constant chimney draft of 10 14 Pascal Pa measured in the flue pipe above the stove when having a smoke exhauster However with natural draft chimney without...

Page 12: ...hauster e g Aduro DraftOptimizer 4 2 Chimney and Smoke If you experience smoke coming out of the stove or the start section of the smoke pipe it could be due to certain weather conditions On stormy or cold winter days or if the chimney has not been used in a while a cold plug can be created in the chimney meaning the natural draft will be at its minimum If the chimney is cold and cold plugs are cr...

Page 13: ...t deflector can be removed To allow free access to the top of the stove and the flue pipe remove the exhaust deflector in steel The flue pipe can be removed from the stove and cleaned Cleaning of the inside of the stove and the flue pipe should be undertaken at least once a year or more frequently if necessary depending on how often the stove is used This work can also be carried out by the chimne...

Page 14: ... installation and use of the stove The right of complaint also does not cover loose and wearing parts glass gaskets firebricks handles slides painted surfaces cast iron grate etc as they are subject to wear during normal use These parts can be bought as spare parts in our webshop www aduroshop com In addition the right of complaint does not cover Damages resulting from incorrect installation and u...

Reviews: