ADTX MasStor K-Series Specifications
Model
AXRR-
K40006S-F
AXRR-
K60006S-F
AXRR-
K80006S-F
AXRR-
K10006S-F
Capacity of each drive
1
(IDE)
40 GB
60 GB
80 GB
100 GB
RAID 0
240 GB
360 GB
480 GB
600 GB
RAID 1
120 GB
180 GB
240 GB
300 GB
RAID 3
200 GB
300 GB
400 GB
500 GB
Usable system
Capacity
1
w/6
drives
(approx.)
RAID 5
200 GB
300 GB
400 GB
500 GB
Drive RPM
7200
7200
7200
7200
Data transfer rates
3
Max/Sustained
Reads/Sustained Writes MB/s
(approx.)
160/110/100
160/110/100
160/110/100
160/110/100
SCSI interface
Ultra 160 (LVD), Dual 68-pin connectors (pass through)
RS-232C interface
One male DB-9 serial port (38400, n, 8, 1) for terminal connection
Power supply rating (each)
peak/continuous
250/223W
Input power requirements
2
(total)
100-240 VAC, 47-63 Hz, 6A peak, 1.4A typ.
Operating temperature
5¼ to 40¼ C
Relative Humidity
10-95%, non-condensing
Altitude
Sea level to 10,000 ft
Weight (approx.) lb./kg
44/20
Dimensions
88 x 437 x 510mm (H - W - D)
1
All capacities are approximate and can vary based upon manufacturing lots for the HDDs.
2
Universal, auto sensing. UL, CSA, TUV approvals. Meets FCC and FTZ regulations.
3
Transfer rates can vary significantly depending upon the HDD.
(These specifications are subject to change without notice. Contact ADTX for the latest information and specification updates)
(ADTX shall not be responsible for any typographical errors within this document)