Chapter 5. Configuration Menu
61200295L1-20
TSU ACE User Manual
5-5
Internal Timing
The TSU ACE
is the source of timing. The TSU ACE
is config-
ured to use its own internal oscillator as the source of timing.
Applications include private line driver circuits where one
end is set to network and the other to internal. See Figure 5-5
.
Figure 5-5. Internal Clock Source
BIT STUFFING
When enabled,
BIT STUFFING
causes the TSU ACE
to monitor for
ones (1s) density violations and insert a one (1) when needed to main-
tain ones at 12.5 percent. This option should be disabled if B8ZS is en-
abled, if Nx56 is selected, or if alternate channels are being used. All
of these other options already ensure pulse density requirements.
Choices: ENA, DISA
SET LBO
SET LBO
selects the line build-out for the network interface. In
AUTO
mode, the TSU ACE
sets the LBO based on the strength of the receive
signal.
Choices: 0dB, AUTO, -22.5dB, -7.5dB, -15dB
RX SENSITIVITY
RX SENSITIVITY
selects the desired receiver sensitivity setting. The
factory default is
NORMAL
which is adequate for most applications.
The extended setting should be used only in applications where the
NORMAL
setting will not suffice.
Summary of Contents for TSU ACE
Page 1: ......
Page 8: ...viii...
Page 16: ...xvi TSU ACE User Manual 61200295L1 20 List of Tables...
Page 28: ...Chapter 1 Introduction 1 12 TSU ACE User Manual 61200295L1 20...
Page 48: ...Chapter 4 Status Menu 4 6 TSU ACE User Manual 61200295L1 20...
Page 58: ...Chapter 5 Configuration Menu 5 10 TSU ACE User Manual 61200295L1 20...
Page 70: ...Chapter 7 Test Menu 7 8 TSU ACE User Manual 61200295L1 20...
Page 76: ...Chapter 8 Example Operations 8 6 TSU ACE User Manual 61200295L1 20...
Page 80: ...Appendix B DTE Data Rate Chart B 2 TSU ACE User Manual 61200295L1 20...
Page 88: ......