background image

TRACER 4x06(L2) Frequency Conversion Document

612804106L2-18A

© 2004 ADTRAN, Inc.

3

4.

Verify the current frequency plan configuration. To verify the plan, check the connections between the 
J connectors (located on the board and labeled 

J1

 and 

J2

) and the Chan connectors (located on the 

diplexer). The Chan connectors are labeled 

2421

 (Chan 1) and 

2462

 (Chan 2) for most TRACER 4106 

systems and 

CH1

 and 

CH2

 for most TRACER 4206 systems. The following table outlines the 

connections for Plan A and B.

Click to see a digital image of the 

J connectors

 othe 

Chan connectors

.

5.

Using the torque wrench, disconnect both cables from the Chan connectors on the diplexer. Do not 
attempt to disconnect the J connectors (located on the board) as this will cause damage. Click 

here

 for 

a digital picture of this step.

6.

Carefully flex the cables to swap the connections. Be careful with the RF cables, making sure that the 
minimum bend radius of the cable is greater than 0.75"; bends and loops smaller than a quarter will 
cause the RF cable to break. Use the wiring guidelines in Figure 3 and Figure 4 on page 4 for help with 
wire placement.

 

Clic

here

 for a digital picture of this step.

Figure 3. TRACER 4106 Cable Routing Diagrams

TRACER 4x06

PLAN

CHAN 1

CHAN 2

A

J2

J1

B

J1

J2

Allowing the RF cables to sit on the processor and radio boards (green) could cause 
damage to the boards; keep the RF cables off the boards while re-routing them. Click 

here

 

for a digital picture of this mistake.

J2

J1

ANT

PLAN B

J1 CABLE OVER ANT CABLE

2421

2462

J2

J1

ANT

PLAN A

J2 CABLE UNDER J1 CABLE

2421

2462

Reviews: