TRACER 2xT1 User’s Manual
61280003L2-1B
Section 3 Operation
25
Preliminary
Char. / Point Type
Scan Point Definition
Description
1 / 1
Status
Frequency Plan
0 = Plan A,
1 = Plan B
1 / 2
Status
10 Second BERT Test
0 = Normal,
1 = In Test
1 / 3 Status
Local T1A Line Loopback
0 = Normal,
1 = Loop
1 / 4
Status
Local T1B Line Loopback
0 = Normal,
1 = Loop
1 / 5
Status
Local T1A Link Loopback
0 = Normal,
1 = Loop
1 / 6
Status
Local T1B Link Loopback
0 = Normal,
1 = Loop
1 / 7
Status
Remote T1A Link Loopback
0 = Normal,
1 = Loop
1 / 8
Status
Remote T1B Link Loopback
0 = Normal,
1 = Loop
2 / 1
Alarm
RFC Link Fail
0 = Normal,
1 = Alarm
2 / 2
Alarm
Code Sync Fail
0 = Normal,
1 = Alarm
2 / 3 Alarm
Carrier Sync Fail
0 = Normal,
1 = Alarm
2 / 4
Alarm
T1 Mux Sync Fail (Link Err)
0 = Normal,
1 = Alarm
2 / 5
Alarm
Remote RF Link Down
0 = Normal,
1 = Alarm
2 / 6
Alarm
RF Low
0 = Normal,
1 = Alarm
2 / 7
Alarm
Remote Test Fail
0 = Normal,
1 = Alarm
2 / 8
Unused
3 / 1
Alarm
T1A BPV
0 = Normal,
1 = Alarm
3 / 2
Alarm
T1A Red Alarm
0 = Normal,
1 = Alarm
3 / 3
Alarm
T1A Yellow Alarm
0 = Normal,
1 = Alarm
3 / 4
Alarm
T1A AIS (Blue Alarm)
0 = Normal,
1 = Alarm
3 / 5
Alarm
T1A Transmit AIS
0 = Normal,
1 = Alarm
3 / 6
Unused
3 / 7
Unused
3 / 8
Unused
4 / 1
Alarm
T1B BPV
0 = Normal,
1 = Alarm
4 / 2
Alarm
T1B Red Alarm
0 = Normal,
1 = Alarm
4 / 3 Alarm
T1B Yellow Alarm
0 = Normal,
1 = Alarm
4 / 4
Alarm
T1B AIS (Blue Alarm)
0 = Normal,
1 = Alarm
4 / 5
Alarm
T1B Transmit AIS
0 = Normal,
1 = Alarm
4 / 6
Unused
4 / 7
Unused
4 / 8
Unused
Table 3-1. TRACER TBOS Alarm and Status Map
A TBOS monitoring system will need to define the following bitmaps to indicate status and alarm
conditions.
Summary of Contents for TRACER 2xT1