TOTAL ACCESS

®

OPTI-T200 

JOB

A

ID

61184400L1-22A

0309

OPTI-T200 

CLEI: SOI4JN6D_ _

DS3

DS3

OPTICS

TX

RX

C
R
A

F
T

STATUS

E

N

E
T

1310 nm

1184400L1

TX

RX

OPTI-T200

LED STATUS

STATUS

Off

No power to unit

Green

Power up and initialization OK

Yellow

Unit is in Out-of-Service – Unassigned mode

Flashing Yellow Unit is in Out-of-Service – Maintenance mode

Red

Unit has an equipment failure

OPTICS

Green

Normal Operation

Yellow

Soft failure (e.g. RDI)

Flashing Yellow Unit in Test (e.g. Loopback)

Red

LOS, LOL, or other hard alarms on optical 
interface

Flashing Red

Unit in Test (e.g. Loopback) with an alarm present
on the Optical Interface

DS3 

Off

DS3 disabled

Green

DS3 normal operation

Yellow

Soft failure (e.g. RDI)

Flashing Yellow Unit in Test (e.g. Loopback)

Red

LOS, LOL, or other hard alarms on DS3 interface

Flashing Red

Unit in Test (e.g. Loopback) with an alarm present
on the DS3 Interface

CRAFT INTERFACE

■ 

Connect to terminal using a serial cable with a male DB-9 connector.

■ 

Set VT100 terminal emulation to 9600 bps, 8 Data Bits, No Parity, 1 Stop Bit,
and No Flow Control.

■ 

Baud rate is configurable at 9600, 19,200, 38,400 or 115,200 bps.

DESCRIPTION

The OPTI-T200 is designed to work in a back-to-back mode of operation,
OPTI-T200 to OPTI-T200.  It uses a standard 1310 nm OC3 signal to interface
between the systems and provides a single DS3 signal to the loop.  The 
OPTI-T200 provides DCC communication with TL1 support.  A craft port and
an Ethernet port are available on the front panel for management.  The 
OPTI-T200 is a T200 mechanics card, which will fit standard T200 and T400
enclosures.

Compliant with SONET standards, the OPTI-T200 functions as a terminal 
multiplexer, detecting standard optical, SONET, and DS3 related alarms and
conditions.  The OPTI-T200 is easily managed with TL1 or TCP/IP commands,
or Telnet sessions separately to each system or via the craft interface.

C A U T I O N 

C A U T I O N ! 

SUBJECT TO ELECTROSTATIC DAMAGE

OR DECREASE IN RELIABILITY.

HANDLING PRECAUTIONS REQUIRED.

■ 

For a complete Installation and Maintenance Practice (P/N 61184400L1-5): 877-457-5007, Faxback Document 918.  Please have your fax number ready.  

INSTALLATION

The OPTI-T200 is a T200 mechanics card which will fit standard T200 and T400 enclosures.
Ensure the appropriate chassis is installed before proceeding with the installation. 

Carefully insert the OPTI-T200 halfway into the selected slot.  Route the fiber cables to the
front panel and approximately 4 inches past the SC receptacles (to create slack).  Gently but
firmly push the OPTI-T200 all the way into the slot, being careful not to pinch the fibers
between the front panel and the shelf. 

WARNING

: Once fully inserted into the chassis, the module will be powered (provided power

is connected to the chassis).

When the OPTI-T200 powers up, it performs a self-test.  The front panel LEDs illuminate for
approximately 8 seconds.  The self-test is complete once the STATUS LED illuminates
Green. 

ALARM CONTACT DEFINITION

Lead

Assignment

Contact (functionally) * Contact Rating

T (pin 7)

Failure detected on optical facility Normally Open

60 VDC

R (pin 13)

0.2 A

T1 (pin 41)

Failure detected on coax facility

Normally Open

1M cycles (min)

R1 (pin 47)

40ºC to +65ºC (temp)

NOTE

: Simultaneous T/R & T1/R1 contact closures used to indicate internal unit failure, loss 

of OC-3/DS-3 inputs, or loss of power.

POWER

: –48VR = Pin 17, –48VDC = Pin 35, Frame-GND = Pin27.

1

2