Chapter 3. Configuration
3-20
MX2800 User Manual
61200290L1-1
Power Supply Alarm Traps
Trap
If enabled, the unit issues a trap when...
Card Removed
the power supply card has been removed.
Malfunction
the power supply card is no longer working and
the unit has switched to the backup power sup-
ply or battery backup.
Card Failure
the power supply card has failed.
Power Low
the power supply’s output level is abnormally
low.
Charger Fail
the battery backup charger has failed or has
lost its AC connection.
Battery Low
the battery backup has reached a critical ener-
gy point at which it may be unable to supply the
unit with sufficient power to maintain operation.
Temperature
High
the power supply card is getting too hot.
Temperature
Critical
the power supply card temperature is so high
that it will soon shut off completely.