61287736G3-22B

3

Figure 3. Connecting SC Connector

3. Clean the ends of the incoming fiber and the SC Connection.
4. Connect the incoming fiber cable to the SC connection.
5. Route the fiber cable through the slot in the protective cover 

and slide it back in place.

6. Replace and secure the panel using the phillips-head screw.

Installing Power

Plug the supplied 12V AC/DC Power Converter into the 

PWR

 

connection on the rear of the chassis. Connect the power plug to a 
standard 120 VAC outlet.

Using a UPS

The SFU ONT can typically use an un-interruptible power supply 
(

UPS

) if desired. Power is supplied to the SFU ONT by a local power 

source with battery backup that utilizes the AC power at the 
customer premises. The UPS powers the SFU ONT and functions as a 
BBU supplying continuous 12 VDC. Refer to the installation material 
that is provided with the UPS when installing the BBU.

Connecting UPS

Connect the UPS to the 8-pin MOLEX connector labeled “UPS” 
located on the rear of the SFU ONT chassis. 

Figure 4 

represents the 

UPS MOLEX connector.

Figure 4. UPS Connector

The UPS Power/Alarm Connections Table at the top on the next 
column defines each pin on the connector. 

Coaxial Connection

Refer to the first illustration in this Job Aid and connect the coaxial 
cable to the connector labeled 

CATV

 on the rear of the SFU ONT.

Protective 

Cover

SC Connector

Note:

This illustration may not

match your ONT, but the

Fiber Installation is the same.

8

7

6

5

4

3

4

3

2

1

UPS Power/Alarm Table

The table below provides a pin-out for the UPS connector.

ON/OFF Button

An On/Off button is located on the far-left side of the rear of the SFU 
ONT. User functionality is limited to this button.

NOTE

If a BBU is being used and is disconnected, the SFU ONT is not
protected from power outages, and will send a “Battery Missing”
alarm to the OLT.

LED S

TATUS

The LEDs are located beneath the plastic housing and are only visible 
after power has been applied. The following table provides the LED 
status during normal operations.

Pin-Out

Description

Alarm

1

Power Input (+12 VDC)

-

2

UPS  Status  -  On  Battery

1

3

UPS Status - Battery Missing

2

4

Signal Return

5

Power  12V  Return

-

6

UPS Status - Replace Battery

3

7

UPS Status - Low Battery

4

8

No Connection 

Label

Status

Indication

PWR

Off
Green

AC or battery off
AC or battery power valid

BATTERY

2

2

Off

Green

Green Flashing 
Slow
Green Flashing Fast

ONT boot or battery missing or 
not equipped
Battery equipped and no bat-
tery alarms present
Loss of AC, on battery

Battery low

LOS

2

2

Off

Red
Red Flashing Slow

Red Flashing Fast

DS signal detected and is 
within margins
No DS signal detected
DS signal is present but mar-
ginal

Software Upgrade failed

ETH 1-4

2

Off
Green
Green Flashing Fast

Link is down or not equipped
Link is up but no data activity
Data is being sent or received

MGMT

Off
Green

MGMT channel not active
MGMT channel active

POTS 1-2

2

Off

Green
Green Flashing 
Slow

Unequipped or on-hook and 
not ringing
One of more lines off-hook
All line on-hook with one of 
more lines in ringing state

WLAN

Not supported