background image

61287737F3-13A

5

LED

S

The LEDs are located beneath the plastic housing and are only 
visible after applying power. The following table provides the LED 
status during normal operations.

If AOE Auto Upgrade is active, a new ONT installation will be 
detected and a new software download will commence. This may 
take 5 to 10 minutes to complete.

Label

Status

Indication

POWER

Off
Green

AC or battery off
No Failure

BAT-

TERY

2

2

Off

Green

Green 

Flashing Slow
Green 

Flashing Fast

ONT boot or battery miss-
ing/not equipped
Battery equipped and no

battery alarms present
Loss of AC, on battery

Battery low

FAIL

Off
Red

Unit is working properly
Red after power-up until

initialization is complete

ETH 

1-4

2

Off

Green
Green 

Flashing Fast

Link is down or not 
equipped
Link is up
Data is being sent or 
received

POTS 

2

Off

Green

Green 

Flashing Slow

Unequipped or on-hook 
and not ringing
Line is in use, not just Off-
Hook
Line in ringing state

MGMT

2

2

Off

Red
Red Flashing 
Slow

Red Flashing 
Fast

DS signal detected and is 
within margins
No DS signal detected
DS signal is present but

marginal

Software Upgrade failed

WLAN

WLAN is not provisioned for this release.

S

PECIFICATIONS

Refer to the following for a list of all specifications for the ONT.

Electrical

Nominal Voltage: 12.0 VDC

Minimum Voltage: 10.0 VDC

Maximum Voltage: 13.9 VDC

Power Consumption: 1.06 Amps @12.0 VDC

AC Power: Included Switching Adapter input range of 100 - 
240 VAC, 50/60 Hz, with a nominal output of 12 VDC

Optical

TX min power: –5.5 dBm

TX max power: –1.0 dBm

RSSI max sensitivity: –27.0 dBm

RX overload: –8 dBm

TX wavelength: 1310 nm typical

RX wavelength: 1490 nm typical

Physical

Height: 1.55 in. (4.0 cm)

Depth: 6.0 in. (15.2 cm)

Width: 10.25 in. (26.0 cm)

Weight: 2 lbs (0.9 kg)

Environmental

Operational Temperature: –5°C to +45°C

Storage Temperature: –40°C to +70°C

Relative Humidity: 0% to 95%, noncondensing

M

AINTENANCE

The ONT does not require routine hardware maintenance for 
normal operation. We do not recommend that you attempt repairs 
in the field. Repair services may be obtained by returning the 
defective unit to ADTRAN. Refer to the warranty for further infor-
mation. Field support for software is provided through upgrade 
facilities.

S

AFETY

 

AND

 R

EGULATORY

Refer to the

 

Safety and Regulatory Notice for this product 

(61287737F3-17) for detailed safety and regulatory information.
Reportez-vous à la sûreté et la réglementation Avis de conformité 
pour ce produit (61287737F3-17) pour la sécurité des 

informations détaillées et réglementaires.
Wenden Sie sich an die Sicherheit und Regulatory Compliance 
und Datenschutz zu diesem Produkt (61287737F3-17) für 
detaillierte Sicherheits-und aufsichtsrechtliche Informationen.

Summary of Contents for Total Access 324E

Page 1: ...tionally by a customer provided Uninterruptible Power Supply UPS AC DC Power Adapter The power feed is supplied through a 12 VDC Power Adapter that is included with the ONT The Power Adapter operates from a wall socket input of 100 240 VAC 50 60 Hz with a nominal output of 12 VDC The total power consumption with 4 Ethernet Ports running and both POTS lines off hook is approximately 13 0 Watts UPS ...

Page 2: ...ion test set PON power meter with wavelength filtering Fiberscope or videoscope Two 8 Pan Head screws 1 inch or greater in length Assorted tie wraps for securing cabling and wiring Fiber optic connections require the following Fiber optical fusion splice tools ODC Fiber cleaning tool SC Fiber connector Installation Steps To install the ONT complete the following steps Step 1 Position the ONT The O...

Page 3: ...ailure to deploy as described could result in permanent damage from lightning or other electrical events and voids the Warranty If it is necessary to connect the ports to remote outdoor equipment or between structures then add an appropriate protection device per the following ADTRAN s Ethernet Port Protection Device EPPD P N 1700502G1 must be connected between the unit and the outside plant cable...

Page 4: ...n Battery 1 3 UPS Status Battery Missing 2 4 Signal Return 5 Power 12 V Return 6 UPS Status Replace Battery 3 7 UPS Status Low Battery 4 8 No Connection 8 7 6 5 4 3 2 1 Step 4 Install Fiber C CAUTION LASER RADIATION 1310 nm to 1490 nm Do not view directly with optical instruments This product contains a Class 1 Laser module that complies with FDA 21 CFR 1040 10 1040 11 and IEC 60825 1 Fiber is ins...

Page 5: ...the ONT Electrical Nominal Voltage 12 0 VDC Minimum Voltage 10 0 VDC Maximum Voltage 13 9 VDC Power Consumption 1 06 Amps 12 0 VDC AC Power Included Switching Adapter input range of 100 240 VAC 50 60 Hz with a nominal output of 12 VDC Optical TX min power 5 5 dBm TX max power 1 0 dBm RSSI max sensitivity 27 0 dBm RX overload 8 dBm TX wavelength 1310 nm typical RX wavelength 1490 nm typical Physica...

Page 6: ...opyright 2020 ADTRAN Inc All Rights Reserved ADTRAN CUSTOMER CARE From within the U S 1 888 423 8726 From outside the U S 1 256 963 8716 PRICING AND AVAILABILITY 1 800 827 0807 61287737F3 13A Documentation for ADTRAN Network Solutions products is available for viewing and download directly from the ADTRAN Support Community website Go to https supportforums adtran com welcome Registration is requir...

Reviews: