Section 61180008L1-5, Issue 2

61180008L1-5B

the user to view all provisioning settings, alarms, and
statistics.  An account with Test privileges will also
allow the account to perform tests.  

Figure 2

illustrates the menu structure of the SCU.

Submenus are elements that move the user down to
the next menu level. Menu items are elements which
allow the user to make changes to the current SCU
settings. There are two different types of menu items:
read-only and read-write.

A read-only menu item displays information that can
not be changed, such as the status of the SCU. A
read-write menu item displays information that when
selected can be changed, such as the baud rate of the
admin port.

Intersystem Communication (RS-485)

The ADTRAN Total Access 1500 SCU supports
communication with other Total Access 1500 systems
over a shared, twisted-pair, half-duplex, RS-485 link.
The SCU from each system is connected in parallel on
this bus. Pin A should be connected to pin A, and Pin
B should be connected to Pin B, so each shelf is in
parallel.  One SCU acts as the master controller and
all others function as slaves. Physical access is
attained by way of wire-wrap posts (P12) on the rear
of the Total Access 1500 Shelf. Up to 32 shelves may
be clustered together via the RS-485 bus.

To set up RS-485 chaining, perform the following:

1. Give the first SCU in the chain a unique Target

ID (TID).

2. Enable RS-485 Interface.

3. Set Interbank Communication Mode to Host.

4. Give the next SCU in the chain a unique Target

ID (TID).

5. Enable RS-485 Interface.

6. Set Interbank Communication Mode to Client.

Repeat steps 4-6 until up to 32 shelves have been
chained.

Setting the Target ID (TID)

A unique Target ID (TID) must be given to each shelf
of a chained RS-485 cluster.  To set the Target ID
(TID) in the Total Access 1500 SCU, perform the
following:

1. Logon to the system.

2. From the Total Access 1500 main menu, select

option 1, System Controller, and press ENTER.

3. From the System Controller menu, select option

2, Provisioning, and press ENTER.

4. From the Provisioning menu, select option 6,

Target ID (TID), and press ENTER.

5. Enter the appropriate Target ID and press

ENTER.

NOTE

The Target ID (TID) may consist of up to 20
characters.  The first character must be a letter.
The remaining characters minus the last character
may  be  alphanumeric  or  a  hyphen.    The  last
character must be alphanumeric.

An example of a Target ID (TID) follows:

HTVLALEXD01

Where:

HTVL

designates the city

AL

designates the state

EX

identifies the Central office or remote
terminal

D

identifies the equipment type ("D" is
administrative equipment)

01

identifies the piece of equipment of
that type at the CO

Summary of Contents for Total Access 1500 SCU

Page 1: ...ry This is the second release of this document This version includes updates describing TL1 over X 25 and TCP IP Features The Total Access 1500 SCU P Ns 1180008L1 1180008L2 and 1180008L3 includes the...

Page 2: ...static packing material when transporting or storing The Total Access 1500 SCU plugs directly into the SCU slot in the common module area of the Total Access 1500 chassis WARNING TheTotalAccess1500SCU...

Page 3: ...m r e T a t a D R T D 5 d n u o r G l a n g i S X 25 Port The SCU supports synchronous RS 232 compatible serial interface to be used in conjunction with an X 25 network The unit includes PAD functions...

Page 4: ...session or a Telnet session VT100 Terminal To connect either a terminal or a PC emulating a terminal to the craft port 1 Set the parameters of the VT100 terminal to 9600 baud rate NOTE The SCU craft...

Page 5: ...m the Management Configuration menu select option 1 IP Address and press ENTER NOTE The IP Address Subnet Mask and Gateway are in the form XXX XXX XXX XXX with the XXX s representing 1 2 or 3 digit de...

Page 6: ...32 shelves may be clustered together via the RS 485 bus To set up RS 485 chaining perform the following 1 Give the first SCU in the chain a unique Target ID TID 2 Enable RS 485 Interface 3 Set Interba...

Page 7: ...Local 1 SCU 2 Online LIU 1 Select Y Modem Upload Destination 3 Modify Checksum 2 Start Y Modem Upload 5 Reset the Y Modem Destination 4 Compute Checksum and Store Unit Name Part Number CLEI Code Prod...

Page 8: ...the Total Access 1500 shelf The following alarm inputs are supported Alarm Wire wrap Header Auxiliary 1 AUX 1 Auxiliary 2 AUX 2 Alarm Cut Off AUX 3 Remote AUX 4 NOTE The front panel mounted ACO switc...

Page 9: ...m u H e v i t a l e R g n i s n e d n o c n o n C 0 5 m u m i x a m 5 9 n o i t a p i s s i D t a e H m u m i x a m s t t a w 4 2 4 e c n a i l p m o C 0 5 9 1 L U 3 l e v e L S B E N E R O C 9 8 0 1...

Page 10: ...mer and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807...

Reviews: