ADTRAN Total Access 1500 SCU Installation And Maintenance Manual Download Page 4

4

Section 61180008L1-5, Issue 2

61180008L1-5B

Table 4.  X.25 Pin Assignments

r

e

b

m

u

N

n

i

P

n

o

i

t

c

n

u

F

1

)

G

F

(

d

n

u

o

r

G

e

m

a

r

F

2

E

T

D

m

o

r

f

)

D

T

(

a

t

a

D

t

i

m

s

m

a

r

T

3

E

T

D

o

t

n

i

)

D

R

(

a

t

a

D

e

v

i

e

c

e

R

4

)

S

T

R

(

d

n

e

S

o

T

t

s

e

u

q

e

R

5

)

S

T

C

(

d

n

e

S

o

T

r

a

e

l

C

6

)

R

S

D

(

y

d

a

e

R

t

e

S

a

t

a

D

7

)

G

S

(

d

n

u

o

r

G

l

a

n

g

i

S

8

)

D

C

D

(

t

c

e

t

e

D

r

e

i

r

r

a

C

a

t

a

D

5

1

k

c

o

l

C

t

i

m

s

m

a

r

T

7

1

k

c

o

l

C

e

v

i

e

c

e

R

0

2

)

R

T

D

(

y

d

a

e

R

l

a

n

i

m

r

e

T

a

t

a

D

2

2

)

I

R

(

r

o

t

a

c

i

d

n

I

g

n

i

R

This port operates as a DTE and is configured for the
following settings:

• 1-way in or 2-way operation

• Up to four SVCs

• Up to 64 kbps (synchronous)

• Packet size: 128 bytes

• Packet window: 2

• n2 retry limit: 3

• T1 ACK timer: 20 seconds

• T3 time out: 3 seconds

• k window size: 2

Ethernet Port

The SCU provides an SNMP interface via a standard
Ethernet 10BaseT connector (J33) located on the
backplane of the Total Access 1500 shelf.

Connect and Logon to System

There are two ways to connect and logon to the
system: via the VT100 craft/admin interface or a
Telnet session.

Total Access shelf management and provisioning is
facilitated by a series of intuitive menus that are
accessible on a computer screen. These menus are
available through either a VT100 terminal session or a
Telnet session.

VT100 Terminal

To connect either a terminal or a PC emulating a
terminal to the craft port:

1. Set the parameters of the VT100 terminal to:

• 9600 baud rate

NOTE

 The SCU craft port is defaulted to 9600 but has
additional available baud rate of 38400.

• 8 data bits

• No parity

• 1 stop bit

• No flow control

2. When connecting a terminal to the craft port and

the terminal has a parallel setting, disable it and
use serial.  When connecting a PC emulating a
VT100 terminal to the craft port, set the PC for
direct connect (as opposed to dial-up
connection).

3. When you are using the front craft port, use a

serial cable with a male DB-9 connector on the
Total Access end.

4. Plug the male end of the data cable into the Total

Access shelf. Make connection to the VT100
terminal as appropriate for your equipment.

5. To logon to the Total Access system, press any

key. When password Authentication is enabled,
the cursor will be placed at the Account Name
field, waiting for an Account Name to be input.

NOTE

The  default  account  name  is  “user”  and  the
default password is “password”.

6. At the Account Name field, input the Account

Name for the Total Access shelf, then press
ENTER. The cursor will be placed at the
Password field, waiting for a Password.

7. At the Password field, enter the Password for the

Total Access System, and press ENTER.

8. Upon entering the correct password, the Total

Access main menu is presented on the screen.
The Total Access menu system can now be
accessed.

Summary of Contents for Total Access 1500 SCU

Page 1: ...ry This is the second release of this document This version includes updates describing TL1 over X 25 and TCP IP Features The Total Access 1500 SCU P Ns 1180008L1 1180008L2 and 1180008L3 includes the...

Page 2: ...static packing material when transporting or storing The Total Access 1500 SCU plugs directly into the SCU slot in the common module area of the Total Access 1500 chassis WARNING TheTotalAccess1500SCU...

Page 3: ...m r e T a t a D R T D 5 d n u o r G l a n g i S X 25 Port The SCU supports synchronous RS 232 compatible serial interface to be used in conjunction with an X 25 network The unit includes PAD functions...

Page 4: ...session or a Telnet session VT100 Terminal To connect either a terminal or a PC emulating a terminal to the craft port 1 Set the parameters of the VT100 terminal to 9600 baud rate NOTE The SCU craft...

Page 5: ...m the Management Configuration menu select option 1 IP Address and press ENTER NOTE The IP Address Subnet Mask and Gateway are in the form XXX XXX XXX XXX with the XXX s representing 1 2 or 3 digit de...

Page 6: ...32 shelves may be clustered together via the RS 485 bus To set up RS 485 chaining perform the following 1 Give the first SCU in the chain a unique Target ID TID 2 Enable RS 485 Interface 3 Set Interba...

Page 7: ...Local 1 SCU 2 Online LIU 1 Select Y Modem Upload Destination 3 Modify Checksum 2 Start Y Modem Upload 5 Reset the Y Modem Destination 4 Compute Checksum and Store Unit Name Part Number CLEI Code Prod...

Page 8: ...the Total Access 1500 shelf The following alarm inputs are supported Alarm Wire wrap Header Auxiliary 1 AUX 1 Auxiliary 2 AUX 2 Alarm Cut Off AUX 3 Remote AUX 4 NOTE The front panel mounted ACO switc...

Page 9: ...m u H e v i t a l e R g n i s n e d n o c n o n C 0 5 m u m i x a m 5 9 n o i t a p i s s i D t a e H m u m i x a m s t t a w 4 2 4 e c n a i l p m o C 0 5 9 1 L U 3 l e v e L S B E N E R O C 9 8 0 1...

Page 10: ...mer and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807...

Reviews: