ADTRAN Total Access 1500 SCU Installation And Maintenance Manual Download Page 1

61180008L1-5B

Section 61180008L1-5, Issue 2

1

Total Access

®

 1500 SCU

Installation and Maintenance

Section 61180008L1-5B

Issue 2, September 2002

CLEI Code L1: VAC1E40J_ _

CLEI Code L2: VAC1E4NJ_ _

CLEI Code L3: VAC1T4NJ_ _

CONTENTS

1.

GENERAL .......................................................... 1

2.

INSTALLATION ............................................... 2

3.

OPERATION...................................................... 3

4.

MAINTENANCE ............................................... 9

5.

PRODUCT SPECIFICATIONS ......................... 9

6.

WARRANTY AND CUSTOMER SERVICE . 10

FIGURES

Figure 1.

Total Access 1500 SCU ........................... 1

Figure 2.

System Controller Menu Tree .................. 7

TABLES

Table 1.

Compliance Codes ................................... 2

Table 2.

Front Panel Description ........................... 3

Table 3.

DCE Pin Assignments .............................. 3

Table 4.

X.25 Pin Assignments .............................. 4

Table 5.

Detailed SCU Specifications ................... 9

Figure 1.  Total Access 1500 SCU

Trademarks: Any brand names and product names included in this document are

trademarks, registered trademarks, or trade names of their respective holders.

1. GENERAL

This practice provides installation and operation
procedures for an ADTRAN Total Access 1500
System Controller Unit (SCU), common modules List
1, List 2, and List 3. 

Figure 1

 shows the Total Access

1500 SCU, List 1, List 2, and List 3.

The SCU comes in the following three configurations:

• List 1 – No Mechanized Loop Test (MLT)

capability.

• List 2 – Central Office Terminal MLT

• List 3 – Remote Terminal MLT

Revision History

This is the second release of this document. This
version includes updates describing TL1 over X.25
and TCP/IP.

Features

The Total Access 1500 SCU, P/Ns 1180008L1,
1180008L2, and 1180008L3, includes the following
features:

• Control all common equipment and access

modules

• Mechanized Loop Test (MLT) capability (L2 and

L3 used together only)

• Provide VT100 craft interface via front panel

DB-9 connector

• Alarm Cut Off (ACO) pushbutton

• Bank status indicators

• Test equipment timing output

• Meet NEBS Level 3 and UL 1950 requirements

• Provides alarm status to NMA and/or SNMP

• Provides internal PAD for X.25 network

• Software can be upgraded while in field without

affecting service

• Operates in Host or Client mode for RS-485

chaining applications

• Supports TL1 over TCP/IP or X.25

• Supports menu access over Telnet

• L2 and L3 monitor primary and secondary power

feeds. L1 does not monitor power feeds.

General Description

The Total Access 1500 SCU is a common module,
plug-in unit designed for the Total Access 1500. The
SCU provides all control functions for the Total
Access 1500 common units and all the individual
access modules.  The SCU manages all network
related functions and communicates externally

HST

MLT
BSY

MJR

T
E
S
T

A
D

M

I

N

MNR

RMT

ACO

1180008L3

SCU RT

HST

MLT
BSY

MJR

T
E
S
T

A
D

M

I

N

MNR

RMT

ACO

1180008L2

SCU COT

HST

PWR

MJR

T
E
S
T

A
D

M

I

N

MNR

RMT

ACO

1180008L1

SCU

List 1

List 2

List 3

Summary of Contents for Total Access 1500 SCU

Page 1: ...ry This is the second release of this document This version includes updates describing TL1 over X 25 and TCP IP Features The Total Access 1500 SCU P Ns 1180008L1 1180008L2 and 1180008L3 includes the...

Page 2: ...static packing material when transporting or storing The Total Access 1500 SCU plugs directly into the SCU slot in the common module area of the Total Access 1500 chassis WARNING TheTotalAccess1500SCU...

Page 3: ...m r e T a t a D R T D 5 d n u o r G l a n g i S X 25 Port The SCU supports synchronous RS 232 compatible serial interface to be used in conjunction with an X 25 network The unit includes PAD functions...

Page 4: ...session or a Telnet session VT100 Terminal To connect either a terminal or a PC emulating a terminal to the craft port 1 Set the parameters of the VT100 terminal to 9600 baud rate NOTE The SCU craft...

Page 5: ...m the Management Configuration menu select option 1 IP Address and press ENTER NOTE The IP Address Subnet Mask and Gateway are in the form XXX XXX XXX XXX with the XXX s representing 1 2 or 3 digit de...

Page 6: ...32 shelves may be clustered together via the RS 485 bus To set up RS 485 chaining perform the following 1 Give the first SCU in the chain a unique Target ID TID 2 Enable RS 485 Interface 3 Set Interba...

Page 7: ...Local 1 SCU 2 Online LIU 1 Select Y Modem Upload Destination 3 Modify Checksum 2 Start Y Modem Upload 5 Reset the Y Modem Destination 4 Compute Checksum and Store Unit Name Part Number CLEI Code Prod...

Page 8: ...the Total Access 1500 shelf The following alarm inputs are supported Alarm Wire wrap Header Auxiliary 1 AUX 1 Auxiliary 2 AUX 2 Alarm Cut Off AUX 3 Remote AUX 4 NOTE The front panel mounted ACO switc...

Page 9: ...m u H e v i t a l e R g n i s n e d n o c n o n C 0 5 m u m i x a m 5 9 n o i t a p i s s i D t a e H m u m i x a m s t t a w 4 2 4 e c n a i l p m o C 0 5 9 1 L U 3 l e v e L S B E N E R O C 9 8 0 1...

Page 10: ...mer and Product Service CAPS prior to returning equipment to ADTRAN For service CAPS requests or further information contact one of the following numbers ADTRAN Sales Pricing Availability 800 827 0807...

Reviews: