9
Section 61180405L1-5, Issue 1
61180405L1-5A
Figure 4. Current System Status Screen
The Current System Status Screen, illustrated in
Figure 4
, provides quick access to FT1 DP status
information.
At each 15-minute interval, the performance
information is transferred to the 15-minute
performance data registers accessed from the
Performance History Screen. At each 24-hour
interval, the performance data is transferred into the
24-hour performance data register also accessed using
this screen.
Figure 4 consolidates current information for the DSL
and DS1 interfaces. A key to the information
provided is found in the center of the screen. Arrows
indicate the key applies to the FT1 DP. The following
defines terms used on this screen:
LOSS ................. Pulse Attenuation Measurement
SYNC ................ DSL Loop Sync Status
ES 15M/24H ...... Errored Seconds
SES 15M/24H .... Severely Errored Seconds
UAS 15M/24H ... Unavailable Seconds
Slot: 4 TOTAL ACCESS SYSTEM 1500 10/05/01 10:10
FT1-DP DSL FT1-DP and FNID STATUS FNID DSL
------------------------ ------------------------
2 db <- LOSS -> 1 db
Yes <- SYNC -> Yes
0/ 23 <- ES 15M/24H -> 0/ 17
0/ 2 <- SES 15M/24H -> 0/ 2
0/ 0 <- UAS 15M/24H -> 0/ 0
Inactive <- LOOPBACKS -> Inactive
Sealing Current Present
Locally Provisioned
FNID DS1
FT1-DP SIGNAL QUALITY ----------------------- FNID SIGNAL QUALITY
(9 = Best, 0 = Worst) FRAME —> ESF (9 = Best, 0 = Worst)
Signal Quality = 9 CODE —> B8ZS Signal Quality = 9
BPV 15M/24H —> 0/ 0
ES 15M/24H —> 0/ 2
SES 15M/24H —> 0/ 5
UAS 15M/24H —> 0/ 5
ALARMS —> None
1. CLEAR PM REGISTERS
Selection:
‘?’ - System Help Screen