background image

8

61220010L2-5, Issue 3

61220010L2-5C

Table 8.  Definition of Screen Abbreviations

Abbreviation and Definition

ES – Errored Seconds: 

A count of the number of seconds in which at least one code violation was detected on a

OOO

       digital circuit.

O

•O IDSL Interface ....Second in which a CRC error occurs.

O

•O Customer DDS Interface....Second in which a bipolar violation occurs.

OO

UAS – Unavailable Seconds: 

A count of the number of seconds that a circuit or path is not available.

O

•O IDSL Interface (U-Interface) ....Will accumulate upon the loss of  loop synchronization or 

OO

the occurrence of 7 errored seconds in a period of 20 seconds.  UAS will stop accumulating upon the

OO

occurrence of 30 consecutive non-errored seconds.

O

•O Customer DDS Interface.... Will accumulate upon the loss of sealing current (LOOP OPEN), loss of

OO

receive signal (LOS), loss of secondary channel framing (LOF), or when the illegal bipolar violation

OO

error rate is >1E-3 for at least 10 seconds.  UAS will stop accumulating upon the occurrence of 10

OO

consecutive non-severely errored seconds.

BPV – Illegal Bipolar Violation

O

•O Customer DDS Interface.... Two consecutive pulses of the same polarity or violation received that

OO

does not alternate in polarity with respect to the prior violation.

INV – Invalid Frame Relay Frame

O

•O Any frame with a CRC error.

O

•O Any frame containing fewer than five octets.

O

•O Any frame containing more than 8191 octets.

O

•O Any frame that does not contain an integral number of octets.

O

•O Any frame containing a frame abort.

OO

FECN – Forward Explicit Congestion Notification

O

•O Count of frames in which the Forward Explicit Congestion Notification bit was set.

O

•O Indicates congestion in the frame relay network but does not isolate cause or location of congestion.

BECN – Backward Explicit Congestion Notification

O

•O Count of valid frames in which the Backward Explicit Congestion Notification bit was set.

O

•O Indicates congestion in the frame relay network but does not isolate cause or location of congestion.

LMI – Local Management Interface

O

•O Local Management Interface (LMI) status is a monitor of the heart beat between the frame switch and

OO

the CPE.

O

•O Recognizes FRF (Annex A), ANSI T1.617 Annex D, and ITU T.933A frame relay interfaces.

O

•O Network and Customer LMI counts should be equal if everything is ok between the frame switch

OO

and the CPE.

O

•O Maintains counts of LMI status messages monitored by the U-Interface, which are sent by the frame

OO

relay switch.

O

•O Maintains counts of LMI status inquiry messages monitored at the DDS Interface which are sent by

OO

the frame relay CPE.

%UT – Frame Relay Percent Utilization

O

•O The average percent utilization over the DS0 channel.OO

Summary of Contents for T200 IDSL

Page 1: ...S Trouble Codes 6 Figure 5 ADTRAN U BR1TE Bidirectional Loopback 6 Figure 6 IDSL DDS Remote End Initiated Loopback Local Loop 7 Figure 7 IDSL DDS Remote End Initiated Loopback Customer Loop 7 Figure 8...

Page 2: ...ar channel capability LED indicators for operational status T200 mechanics Transmits Abnormal Station Code upstream during out of service 4 wire customer loop condition Figure 2 IDSL DDS Circuit Diagr...

Page 3: ...ll permit the IDSL OCU R to respond to the legacy latching loopback sequence per TR62310 and ANSI T1 417 At 64 kbps with LLEN OFF the IDSL OCU R enables ADTRAN s Protected Loopback Protected Loopback...

Page 4: ...customer port is classified as suitable for connection to intra building or non exposed wiring only r i a P p i r t S l a n i m r e T s n o i t a n g i s e D s n o i t a n g i s e D s n o i t a n g i...

Page 5: ...i b r o f t s e t k c a b p o o l r a e l C f o s e t y b e v i t u c e s n o c r u o F e d o c k c a b p o o l d e i f i c e p s U C O 0 1 0 1 0 1 0 X U S C 0 0 0 1 0 1 0 X U S D 0 0 1 1 0 1 0 X h t...

Page 6: ...ime initiates a loopback at the IDSL OCU R towards the 4 wire DDS CPE interface A solid CUST LBK on the IDSL OCU R indicates a loopback at the IDSL OCU R towards the customer equipment See Figure 7 Pr...

Page 7: ...capability disable all power saving programs Otherwise communication between the PC and the IDSL OCU R unit can be disrupted resulting in misplaced characters or screen timeouts Operation The T200 ID...

Page 8: ...ation INV Invalid Frame Relay Frame O O Any frame with a CRC error O O Any frame containing fewer than five octets O O Any frame containing more than 8191 octets O O Any frame that does not contain an...

Page 9: ...ure 9 Main Menu Screen CIRCUIT ID IDSL Test Unit 07 25 00 02 14 40 Adtran IDSL Main Menu 1 Status 2 Loopbacks 3 Performance Monitoring 4 Event Log 5 Set Circuit ID 6 Set Date and Time 7 Adtran Informa...

Page 10: ..._______ ____________ UBR1TE OCU R NETWORK 000 000 CUSTOMER MARGIN 20 ATTEN 00dB ____________ ____________ 1 Legend 2 Detailed Status Selection Figure 12 IDSL Detailed Status Screen CIRCUIT ID IDSL Tes...

Page 11: ...for the last 25 hours At each 24 hour interval the performance data is transferred into the 24 hour performance data register also accessed using this screen The Performance Monitoring screens are sh...

Page 12: ...0000 01 45 000 000 00000 01 45 000 000 00000 000 000 00000 01 30 000 000 00000 01 30 000 000 00000 000 000 00000 01 15 000 000 00000 01 15 000 000 00000 000 000 00000 01 00 000 000 00000 01 00 000 000...

Page 13: ...00000 00000 00000 000 00 45 00000 00000 00000 00000 000 00 30 00000 00000 00000 00000 000 00 30 00000 00000 00000 00000 000 00 15 00000 00000 00000 00000 000 00 15 00000 00000 00000 00000 000 00 00 0...

Page 14: ...to virtually a 0 BER Figure 19 Event Log Screen The Set Circuit ID screen Figure 20 sets the circuit identification Figure 20 Set Circuit ID Screen CIRCUIT ID IDSL Test Unit 07 25 00 02 38 13 EVENT L...

Page 15: ...the IDSL OCU R Figure 22 ADTRAN Information Screen CIRCUIT ID IDSL Test Unit 07 25 00 02 39 32 Support Hours 7am 7pm CST Emergency 7days x 24hrs Phone 800 726 8663 Fax 256 963 6217 Internet www adtran...

Page 16: ...ablishment and remains ON after the IDSL OCU R has been remotely provisioned If the IDSL OCU R has been remotely provisioned the operator can alternate between remote configuration and manual switch s...

Page 17: ...bility 800 827 0807 ADTRAN Technical Support Pre sales Applications Post sales Technical Assistance 800 726 8663 Standard hours Monday Friday 7 a m 7 p m CST Emergency hours 7 days week 24 hours day A...

Page 18: ...18 61220010L2 5 Issue 3 61220010L2 5C...

Reviews: