Menu Descriptions
61179641AL1-5C
5-107
E1 Status Menu
E1 Status
\
\E1 Status\
The E1 Status Menu (see
) displays the status of the E1 network circuits and a
summary of the associated alarm counts.
Figure 5-71. E1 Status Menu
The E1 Status menu options are shown in
Table 5-73. E1 Status Menu Options
Option
Field
Function
N/A
Framing
This field displays the framing setting for the E1 circuit.
For more information, see
N/A
Line Code
This field displays the line code setting for the E1
circuit. For more information, see
N/A
E1 Alarm
This field indicates if there are any E1 alarms.
N/A
Total Alarms Red
This field indicates the number of Loss of Signal (Red)
alarms.
N/A
Total Alarms Yellow
This field indicates the number of Receive Remote Alarm
Indication (Yellow) alarms.
N/A
Total Alarms Blue
This field indicates the number of Receive Alarm
Indication Signal (Blue) alarms.
8
Reset Alarm Counts
This option is used to clear all the E1 status alarm
fields.
TID: TA1248 Total Access 1248 MM/DD/YY HH:MM
Unacknowledged Alarms: None
E1 Status
1 2 3 4
Framing FAS+CRC FAS+CRC FAS+CRC FAS+CRC
Line Code HDB3 HDB3 HDB3 HDB3
E1 Alarm RED RED RED RED
Total Alarms
Red 2 2 2 2
Yellow 0 0 0 0
Blue 0 0 0 0
8. Reset Alarm Counts Cleared:
Selection :
'?' - System Help Screen