Menu Descriptions
61181307L7-5E
15
• Enter Test Timeout – This option displays the Network Timeout scree
n
). The
timeout can run for a specific duration by entering the hours and/or minutes, or can run
indefinitely by entering 00:00.
Figure 14. Network Timeout Screen
• Toggle Test Direction – When a test is not running, this option is used to toggle the test
signal in the opposite direction (from customer to network and vice versa). When a test is
running, this option changes to Inject Bit Errors (
). This allows errors to be
generated from the test origination point to validate the test results.
Figure 15. BERT Inject Errors Screen
Shelf: 1 Slot: 2 Total Access System mm/dd/yy hh:mm
Unacknowledged Alarms:
NETWORK Timeout Screen
Test Timeout(Hr:Min) = 01:00
----------------------------
1. Change Timeout
*NOTE: When timeout is set to 00:00, the
test will run indefinitely.
Selection:
Shelf: 1 Slot: 2 Total Access System mm/dd/yy hh:mm
Unacknowledged Alarms:
CH 1 Circuit ID:
Channel 1 BERT Test Screen
Test Results
-----------------------------------------------------
Test Direction: T1 Interface
Unframed Pattern Generation: ON
Pattern: 63 Pattern
Line Coding: B8ZS
Bit Errors: 0000000
Bit Error Rate: 0.0E-09
Pattern Sync: ACQUIRED
Pattern Sync Losses: 000
Test Length (HH:MM:SS): 01:01:00
Time Elapsed (HH:MM:SS): 00:01:30
-----------------------------------------------------
1. Number of Errors to Inject = 002 (Maximum=255)
2. Inject Bit Error
3. (Re)start
Selection: