background image

Chapter 3.  Operation

36

NxT1 HSSI/V.35 Module User Manual

61200771L1-1

C

ONFIG

Read Security: 5; Write Security: 5

Contains parameters to include T1 data streams to the HSSI interface.

P

RT

Displays the port number for the T1s mapped to the NxT1 HSSI 
interface. Ports 1 through 4 are the T1 interfaces located on the 
NxT1 HSSI Option Module. Ports 5 through 8 are T1s mapped to 
the NxT1 HSSI Option Module in the Dedicated Maps. 

G

ROUP

 A

SSOCIATION

Associates T1s (either mapped to this card and/or the on-board T1s) 
with the HSSI interface data stream. To add the T1 to the data 
stream, select the 

G

ROUP

1

 option.

S

CRAMBLE

Enabling the 

S

CRAMBLE

 option configures the NxT1 HSSI Module 

to prevent ones density violations when transmitting ADTRAN 
IMUX headers on a T1 circuit with AMI line coding.

HSSI M

ENUS

Read Security: 5

Provides status, configuration, and testing  parameters for the 50-pin SCSI-
II HSSI interface.

S

TATUS

Read Security: 5

Displays the current loopback status of the HSSI interface

L

OOPBACK

Displays the current loopback status of the HSSI interface. The fol-
lowing loopback options are possible (see Figure 3-4 on page 37):

L

OCAL

 DTE L

OOPBACK

A local DTE loopback occurs at the DTE port of the DCE, and is 
used to test the link between the DTE and DCE (NxT1HSSI mod-
ule).

L

OCAL

 L

INE

 L

OOPBACK

A local line loopback occurs in the IMUX engine and is used to test 
functionality between the DTE and the IMUX engine. 

R

EMOTE

 L

INE

 L

OOPBACK

A remote line loopback occurs at the T1 interface and is used to test 
functionality between the DTE and the T1 interfaces.

Use extreme caution when disabling the 

S

CRAMBLE

 option. ADTRAN recommends 

enabling the 

S

CRAMBLE

 option for normal use.

Summary of Contents for NxT1 HSSI/V-35

Page 1: ...NxT1 HSSI V 35 Module User Manual Part Number 1200771L1 61200771L1 1A March 2002...

Page 2: ...901 Explorer Boulevard P O Box 140000 Huntsville AL 35814 4000 256 963 8000 2002 ADTRAN Inc All Rights Reserved Printed in U S A...

Page 3: ...orm There is a remote risk of shock from lightning 3 Do not use the telephone to report a gas leak in the vicinity of the leak 4 Use only the power cord power supply and or batteries indicated in the...

Page 4: ...n the network The affidavit shall affirm that either no encoded analog content or billing information is being transmitted or that the output of the device meets Part 68 encoded analog content or bill...

Page 5: ...CPE does not transmit digital signals containing encoded analog content or billing information which is intended to be decoded within the telecommunications network The encoded analog content and bill...

Page 6: ...the preceding paragraph if so requested _________________________________Signature _________________________________Title _________________________________ Date Transcribed and sworn to before me This...

Page 7: ...until the problem is corrected or it is certain the equipment is not malfunctioning 5 This unit contains no user serviceable parts 6 An FCC compliant telephone cord with a modular plug is provided wi...

Page 8: ...l environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio frequ...

Page 9: ...o a telephone interface The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the RENs of all the devices should not exceed five 5 C...

Page 10: ...o a condition as warranted Customer is entitled to a full refund of the purchase price upon return of the equipment to ADTRAN This warranty applies only to the original purchaser and is not transferab...

Page 11: ...ouse or possible fees associated with repair Identify the RMA number clearly on the package below address and return to the following address ADTRAN Customer and Product Service 901 Explorer Blvd East...

Page 12: ...multiple types and levels of installation and maintenance services which allow you to choose the kind of assistance you need This support is available at http www adtran com aces For questions call th...

Page 13: ...tallation 23 Before Installing the NxT1 HSSI V 35 Module 23 Shipping Contents 23 Installing the NxT1 HSSI V 35 Module 24 Wiring 25 Power Up and Initialization 26 Failed Self Test 26 Operation Alarms 2...

Page 14: ...s 35 HSSI Menus 36 ATLAS Features Used with NxT1 HSSI V 35 Module Options 39 Factory Restore 39 Run Selftest 39 Appendix A Dedicated Maps Configuration 41 Auto 41 Maps 1 through 5 41 42 Map Name 42 So...

Page 15: ...61200771L1 1 NxT1 HSSI V 35 User Manual 15 List of Tables Table 2 1 T1 Pinout Connection 25 Table 2 2 HSSI V 35 SCSI 50 Pinout 25 Table 3 1 Menu Tree for NxT1 HSSI V 35 Modules Menu 29...

Page 16: ...List of Tables 16 NxT1 HSSI V 35 User Manual 61200771L1 1...

Page 17: ...Figure 1 2 NxT1 HSSI V 35 Option Module 22 Figure 2 1 Installing the NxT1 HSSI V 35 Module 24 Figure 3 1 Modules Menu 28 Figure 3 2 NxT1 HSSI V 35 Module Menu Options 31 Figure 3 3 T1 Loopback Test D...

Page 18: ...List of Figures 18 NxT1 HSSI V 35 User Manual 61200771L1 1...

Page 19: ...e when needed When using the NxT1 HSSI V 35 Module in a V 35 configuration up to 4 T1s of aggregated bandwidth is supported The inverse multiplexing capacity of the module accommodates eight T1s and t...

Page 20: ...inal menus accessible through either a VT 100 terminal connected to the ATLAS 800 Series control port or via a Telnet session established through the unit s Ethernet port Use the terminal menu to conf...

Page 21: ...e Rate Up to 11 04 Mbps T1 Links 1 to 8 Total T1 Links in any combination of module T1 interfaces and other T1 T3 modules Connector 50 pin SCSI II Female The V 35 interface of the NxT1 HSSI V 35 Modul...

Page 22: ...SI V 35 Module see Figure 1 2 plugs into any available option slot in the rear of the supported ATLAS 800 Series units Figure 1 2 NxT1 HSSI V 35 Option Module The label over each RJ 48C connector refe...

Page 23: ...f this manual for pertinent information If possible keep the original shipping container for returning the NxT1 HSSI V 35 Module for repair or for verification of shipping damage Shipping Contents The...

Page 24: ...1 HSSI V 35 Module Step Action 1 Remove the cover plate from the appropriate option slot in the ATLAS 800 Series chassis rear panel 2 Slide the NxT1 HSSI V 35 Module into the option slot until the mod...

Page 25: ...from the network ring 2 T1 RXDATA Receive data from the network tip 3 6 7 8 Unused n a 4 R TXDATA Send data towards the network ring 5 T TXDATA Send data towards the network tip Connector Type 50 pin...

Page 26: ...p See the appropriate ATLAS 800 Series User Manual for details Operation Alarms The red ALARM LED located with the Module LEDs on the front panel illuminates when an alarm condition is detected PIN si...

Page 27: ...ctions on the operation of each of these management approaches TERMINAL MENU STRUCTURE ATLAS 800 Series uses a hierarchical menu structure to provide access to all of its features The top most menu le...

Page 28: ...5 Module when it is installed in the system To see the menus for the NxT1 HSSI V 35 Module via the terminal menu use the arrow keys to scroll to the Modules menu and press ENTER to access the module c...

Page 29: ...e field automatically defaults to NXT1 HSSI the NxT1 HSSI V 35 Module You can use this field to preconfigure a system before actually Part Number Serial Number Info Assembly Revision Firmware Revision...

Page 30: ...must be marked as online for it to be considered an available resource This field allows an installed module to be marked as of fline which may be useful in system troubleshooting If you choose OFFLIN...

Page 31: ...The module is still responding to controller polls OFFLINE NO RESPONSE The module is installed but has been taken offline by a user The module is not responding to polls REV This read only field displ...

Page 32: ...d security 5 Displays the part number of the module SERIAL NUMBER Read security 5 Displays the serial number of the module ASSEMBLY REVISION Read security 5 Displays the assembly revision FIRMWARE REV...

Page 33: ...hat is at least one DS0 channel is in alarm if an asterisk appears These alarms usually indicate the failure to receive the protocol that has been configured for the DS0 RX LEVEL Receive Level Indicat...

Page 34: ...l of the following configurable parameters apply to whether the port is connected to a Primary Rate ISDN circuit or a channelized T1 circuit PRT Displays the port number PORT NAME Accepts any alpha nu...

Page 35: ...ft options For long haul out of plant applications choose from the dB options When you select this item a list of choices displays Select the appropriate option TEST Write security 3 Read security 5...

Page 36: ...UX headers on a T1 circuit with AMI line coding HSSI MENUS Read Security 5 Provides status configuration and testing parameters for the 50 pin SCSI II HSSI interface STATUS Read Security 5 Displays th...

Page 37: ...send and receive data to and from the DCE Valid data transmission should not commence until CA has also been asserted by the DCE If the data communications channel requires a keep alive data pattern...

Page 38: ...lock which compensates for a long cable CA Not applicable in V 35 mode Asserts the data Communications equipment Available signal from the DCE CA will be asserted by the DCE independently of TA when t...

Page 39: ...re stores the factory settings for all of the module options or while the cursor is over an individual field this action restores factory settings only for the particular field RUN SELFTEST RUN SELFT...

Page 40: ...Chapter 3 Operation 40 NxT1 HSSI V 35 Module User Manual 61200771L1 1...

Page 41: ...Dedicated Maps Menu ACTIVATE MAP Write security 3 Read security 5 Activates a dedicated map automatically or manually You can have up to five different dedicated maps each with an optionally specifie...

Page 42: ...the end points set in CONNECTS FROM CON FIG and CONNECTS TO CONFIG You can also turn OFF this option The sort feature is helpful when you are attempting to find a particular connec tion in a large co...

Page 43: ...option or resource module TO CONFIG Write security 3 Read security 5 Specifies the configuration for the TO connection The selections displayed in this field are based on the type of module selected...

Page 44: ...git that displays in this field repre sents the last digit of the DS0 number This DS0 has been requested for this connection but the DS0 is not yet activated for this port This DS0 is used by this por...

Page 45: ...e data field for outgo ing DS0s which are cross connected to a T1 port experiencing alarms The trunk conditioning process consists of a 2 5 second transmis sion indicating call termination followed by...

Page 46: ...Appendix A Dedicated Maps Configuration 46 NxT1 HSSI V 35 User Manual 61200771L1 1...

Page 47: ...stallation Diagram 24 Steps 24 Installing the Module 24 L Loopback HSSI Interface Diagram 37 T1 Diagram 35 M Menu Modules 28 NxT1 HSSI Modules 31 Menu Tree 29 P Physical Description 22 R RJ 48C Pinout...

Page 48: ...Index Index 48 NxT1 HSSI V 35 User Manual 61200771L1 1...

Reviews: