NetVanta 6310/6330 Series Hardware Installation Guide
Unit Installation
61700100G1-34F
Copyright © 2013 ADTRAN, Inc.
41
Installing Network and Voice Interface Modules
The NIM2s/VIM2s are installed into the rear panel option module slots. The following table lists the installation
steps. Also, see
Figure 19
below.
Figure 19. NIM2/VIM2 Installation
For NetVanta modules with outside plant connections, ensure that all cables are
removed from the module before installing or removing it from the NetVanta chassis.
•
Electronic modules can be damaged by static electrical discharge. Before handling
modules, put on an antistatic discharge wrist strap to prevent damage to electrical
components. Place modules in antistatic packing material when transporting or
storing. When working on modules, always place them on an approved antistatic mat
that is electrically grounded.
•
Always remove power from the unit prior to removing or installing a module.
•
Improper installation could result in damage to the modules.
Instructions for Installing the NIM2s/VIM2s
Step
Action
1
Remove power from the unit.
2
Use a screwdriver to remove the cover plate from the appropriate option slot in the NetVanta
base unit.
3
Slide the option module into the option slot until the module is firmly seated against the chassis.
4
Secure the screws at both edges of the module.
5
Connect the cables to the associated device(s).
6
Restore power to the unit.
PRI 0/1
SLOT 2
SLOT 1
ETH 0/1
ETH 0/2